11 12
6
button to reset, the pump will work 40 seconds until the LCD
panel display interface for Picture 3, haze machine work
normally.
If the tank still have liquid inside but the machine show
“ Out
Order
”, please check the liquid tube and fast connector of bottle
cap firstly and then check the pump.
Picture 7. Fluid protection
5.5 FLUID PROTECTION SYSTEM ON AND OFF SETTING
METHOD
If you press many times
“ MANUAL” button but can not get back
from
“ Out Order” when all the spare parts in normal, you can
press six times
“ FUNC” button and then LCD show picture 8
“ Oil-Way”, press “UP” button one time, LCD show “ OFF”, and
then press
“ FUNC” button to turn off the fluid protection system.
Press
“ VOLUME” button and adjust the smoke output into
100%, waiting for 1-2minutes, machine will work normally.
Press
“ FUNC” button six time LCD show piecture 8 “ Oil-way”,
press
“ DOWN” button LCD show “ ON” and then press “FUNC”
again to turn on the fluid protection system.
Picture 8. Fluid protection System ON and OFF
6. Care and Maintenance
It can reduce spare parts change and repair charge if you clean
the machine termly.
※
Remove the filter,which protects the fan against dust and
dirt,from time to time and clean it.
※
Check the state of the fluid filter from time to time and clean or
replace it when necessary.
※
After several hours of operation,some droplets of condensation
will have formed at the nozzle. That is normal and not a
malfunction.
※
Remove fluid droplets at the nozzle only when the machine has
completely cooled off.
※
Please keep the liquid clean,do not put in other material. Do not
using the contaminate liquid. Please lid the bottle after putting in
the liquid.
※
Please note: The vaporizer of our machines does not have to
be cleaned! If open and clean by yourself not professional and
damage the vaporizer,we can not grant warranty in this case.