background image

BUTTON

FUNCTION

Press the “ON/OFF” button, the light goes to constant on/off mode, sensor is 

disabled.  Press “Reset” or “Sensor motion” button to quit from this mode and the 

sensor starts to work

Press “Reset” button, all parameters are same as setting of DIP switch or factory 

settings.  

Press “Sensor motion” button, the light quits from the constant on/off mode, and 

the sensor starts to work (The latest setting stays in validity)  

Press “DIM Test” button, the 1-10 V dimming works to test whether the 1-10Vdc 

dimming ports are connected properly. After 2s, it returns to the latest setting 

automatically.  

Short press “DIM+ / DIM-“ button to transmit dimming signal. The brightness of 

the lamp adjusts at 5% per unit.  

(only apply for sensor with daylight harvesting function) 

Long press>3s, sensor will take current light level as target lux level, to dim up/

down load automatically according to the change of ambient light level. (only 

apply for sensor with daylight harvesting function) 

Note: Detection area / Hold time / Stand-by period / Stand-by dim level / 

Daylight sensor can be adjusted by pressing the corresponding button. The latest 

setting will stay valid.

Press the “TEST 2S” button can enter the test mode anytime. At the mode, the 

sensor parameters as below: Detection Area is 100%, Hold Time is 2s, Stand-by 

Dim Level is 10%, Stand-by Period is 0s, daylight sensor disable. This function 

only for testing. Quit the mode by pressing “RESET” or any other functions 

buttons. 

Scene 

Options

Detection 

Area

Hold time

Stand-by 

period

Stand-by  

dim level

Daylight 

Sensor

Induction 

model

QS1

100%

30S

1min

10%

5Lux

Hs

QS2

100%

1min

3min

10%

10Lux

Hs

QS3

100%

5min

10min

10%

30Lux

Hs