background image

vi

HXP100-MECA & HXP100HA-MECA

6-Axis-Parallel Kinematic Positioning Systems

Definitions and Symbols

The following terms and symbols are used in this documentation and also

appear on the product where safety-related issues occur.

General Warning or Caution

The exclamation symbol may appear in warning and caution tables in this

document. This symbol designates an area where personal injury or

damage to the equipment is possible.

The following are definitions of the Warnings, Cautions and Notes that may

be used in this manual to call attention to important information regarding

personal safety, safety and preservation of the equipment, or important

tips.

WARNING

Warning indicates a potentially dangerous situation which can result in
bodily harm or death.

CAUTION

Caution indicates a potentially hazardous situation which can result in
damage to product or equipment.

NOTE

Note indicates additional information that must be considered by the
user or operator.

European Union CE Mark

The presence of the CE Mark on Newport Corporation equipment means

that it has been designed, tested and certified as complying with all

applicable European Union (CE) regulations and recommendations.

Warnings and Cautions

ATTENTION

This stage is a Class A device. In a residential environment, this device
can cause electromagnetic interference. In this case, suitable measures
must be taken by the user.

A

698J

0

 - 

EDH0

23

9

En10

7

0 - 12/19

Содержание Newport HXP100-MECA

Страница 1: ...6 Axis Parallel Kinematic Positioning Systems HXP100 MECA HXP100HA MECA Hexapods USER S MANUAL A698J...

Страница 2: ...s expressed or implied including any implied warranty of merchantability or fitness for a particular use Newport Corporation shall not be liable for any indirect special or consequential damages by Ne...

Страница 3: ...ription 2 3 0 Characteristics 3 3 1 Mechanical Specifications 3 3 2 Guaranteed Specifications of the HXP100HA MECA Version 4 3 3 Max Cantilever Distance of the Load 4 3 4 Weight 4 4 0 Connection to th...

Страница 4: ...iv HXP100 MECA HXP100HA MECA 6 Axis Parallel Kinematic Positioning Systems A698J0 EDH0239En1070 12 19...

Страница 5: ...t provisions of the Directive 2006 42 EC on machinery complies with all the relevant provisions of the Directive 2014 30 EU relating to electro magnetic compatibility complies with all the relevant pr...

Страница 6: ...nd preservation of the equipment or important tips WARNING Warning indicates a potentially dangerous situation which can result in bodily harm or death CAUTION Caution indicates a potentially hazardou...

Страница 7: ...as entered the Hexapod switch off struts power and then disconnect the HXP controller from power supply Contact your Newport service facility and request repairs WARNING Do not insert or drop objects...

Страница 8: ...leave this Hexapod in places subject to extremely high temperatures or low temperatures This may cause an electric shock Operating temperature 10 to 35 C Storage temperature 10 to 40 C in its origina...

Страница 9: ...This manual provides operating instructions for the Hexapod that you have purchased CAUTION Please read chapters 3 3 and 5 0 carefully before operating your Hexapod CAUTION Do not use the HXP100 MECA...

Страница 10: ...nation achieves positioning performance close to standard Newport stages The HXP100 ELEC D and HXP100HA ELEC D provide advanced features including instrument grade I O s hardware based input triggers...

Страница 11: ...s 2 0 Z Motion mm 0 0 2 0 4 0 6 0 8 1 0 1 2 1 4 1 6 1 8 30 0 10 20 10 20 X Motion mm Hexapod Trajectory 30 Standard Motion RightPath X Y Z U Rx V Ry W Rz Travel range 1 27 5 mm 25 mm 14 mm 11 5 10 5 1...

Страница 12: ...0 0 20 40 60 Radial Distance D mm Load Position D 0 to 140 mm H 0 to 200 mm Load 80 100 120 140 H 0 H 100 H 200 H D Weight lb kg Hexapod without cables 15 9 7 2 Cables 2 2 1 0 X Y Z Uni directional r...

Страница 13: ...u clean the electronics unit CAUTION To protect the unit from damage be sure to Keep all air vents free of dirt and dust Keep all liquids away from the unit Do not expose the unit to excessive moistur...

Страница 14: ...t 4 3 Cables Each Hexapod is equipped with 3 meter cables terminated with SUB D25M connectors and can be directly connected to the HXP100 ELEC D or HXP100HA ELEC D controller Length from actuators Rem...

Страница 15: ...on and home preset These parameters have to be set into the controller for each strut This is done at our factory when the Hexapod is ordered with its own HXP100 ELEC D or HXP100HA ELEC D controller W...

Страница 16: ...HD 1 ON SQR 1 97 50 6 HOLES M6 THD 1 EQUIDISTANT AT 60 ON 6 9 175 TOP PLATE BASE PLATE 1 HOLE 394 006 10H7 DEPTH 31 8 0 1 HOLE M6 THD DEPTH 20 5 MODEL SHOWN HXP100 MECA DIMENSIONS IN INCHES AND MILLIM...

Страница 17: ...s RECOMMENDATION It is recommended to return the Hexapod to Newport for re lubrication after 2000 hours of use If the HXP100 MECA is mounted on a workstation and cannot be easily removed please contac...

Страница 18: ...10 HXP100 MECA HXP100HA MECA 6 Axis Parallel Kinematic Positioning Systems A698J0 EDH0239En1070 12 19...

Страница 19: ...s Country P O Number Item s Being Returned Model Description Reasons of return of goods please list any specific problems Return authorization Please obtain prior to return of item Date Phone Number F...

Страница 20: ...sales newport com Technical Support Tel 800 222 6440 e mail tech newport com Service RMAs Returns Tel 800 222 6440 e mail service newport com Europe MICRO CONTROLE Spectra Physics S A S 9 rue du Bois...

Отзывы: