![MK Diamond Products MK-101-24HD Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/mk-diamond-products/mk-101-24hd/mk-101-24hd_owners-manual-and-operating-instructions_1813135044.webp)
44
(A)
Remove the Cooling Transfer
Tube from the Blade Guard
inlet. Go to Step C.
(B)
Place Pump into a bucket of
water and check flow. If flow
exists, go to Step D.
(C)
Remove the Cooling Transfer
Tube and check for flow. If flow
exists, refer to water pump
manual.
(D)
Remove the Blade Guard
Intake Fitting. Go to Step F.
(E)
Remove the Cooling Channel
cover screws. Go to step G.
(F)
Rod the Cooling Channels
and then recheck flow.
“Rodding” cooling channels is performed by inserting a small wire rod through the
cooling inlet on top of the Blade Guard and directing the rod out through each of the
cooling flow tubes located on the underside of the Blade Guard. The cooling chan-
nels should be “rodded” until all ports are free of foreign debris.
MK-101-24HD
TROUBLESHOOTING
Cooling Flow
NOTE:
Содержание MK-101-24HD
Страница 19: ...19 NOTES ...