MJK 202925 Скачать руководство пользователя страница 12

12

Manual

Manual Expert 1400/3400 GB 0704

MJK Automation A/S

Byageren 7
DK-2850 Naerum 
Denmark 
Tel.:  +45 45 56 06 56 
Fax:  +45 45 56 06 46 
[email protected] 
www.mjk.com

MJK Expert™ 1400 Level Transmitter has 

about the same specifications as the 7070 

model. In addition it has a ceramic, capaci-

tive measuring system with a much higher 

accuracy. Furthermore, Expert™ 1400 is 

approved for use in explosion hazardous 

areas: ATEX Ex ia IIC T6.
Model 1400 is very useful for level measure-

ments in for example ground water bore 

holes and in-fill sites, where explosion proof 

transmitters are required.

Specifications

MJK Expert™ 1400 Hydrostatic Level Transmitter

Nominal measuring range

0 - 0,3 m

0 - 1 m

0 - 3 m 

0 - 5 m

0 - 10 m

0 - 30 m

0 - 100 m

0 - 300 m

Measuring principle

Ceramic capacitive, relative pressure

Min. programmable range

0 - 0,3 m 0 - 0,3 m

0 - 1 m

0 - 3 m

0 - 3 m

0 - 10 m

0 - 30 m

0 - 90 m

Max. programmable range

0 - 1 m

0 - 1 m

0 - 3 m

0 - 10 m

0 - 10 m

0 - 30 m

0 - 100 m

0 - 300 m

Max. overpressure

4 bar

4 bar

6 bar

10 bar

10 bar

18 bar

40 bar

40 bar

Temperature range

-20 °C to 40 °C

Temp. deviation, 0 point

Better than ± 0.02 % / °C

Temperature deviation, FS

Better than ± 0.01 % / °C

Linearity / Stability

Better than ± 0.2 % FS / ± 0.2 % FS

Measurement accuracy

Better than ± 0.1 % FS @ +10 to 30 °C 
Better than ± 0.2 % FS @ full temperature range

Long time stability

Better than ± 0.1 % FS per year

Materials

Housing: stainless steel (AISI 316 L), diaphragm: 96,6 % Al

2

O

3

/Cell packing: Viton

®

Supply voltage

10 - 30 V DC (12 - 30 V DC for cable lengths above 100 m)

Output signal

2-wire 4 - 20 mA (passive transmitter)

Cable

2 × 0,5 mm

 (pressure) + 5 x 0,15 mm

2

 (data), shielded, PUR insulation

Cable length

12 m

12 m

12 m

12 m

12 m

35 m

110 m

320 m

Enclosure

IP 68, withstands a static pressure equal to max. overpressure.

Approvals

ATEX: II 2G EEx ia IIC T5/T6 and CE: EN61000-6-3/-4:2001, EN61000-6-1/-2:1999, 
EN50014:1997 E, EN50020:2002

 

 Can be delivered with other cable lengths on request.

Dia. 24 mm

73 mm

Order Numbers

Dimensions and  

Accessories

Cable bracket for MJK Expert™ 1400 
Level Transmitter
(1 pc. is delivered with each transmitter)

MJK Expert™ 1400 
Level Transmitter

152 mm

65 mm

Dia. 22 mm

Data Sheet for 

Expert™ 1400 Level 

Transmitter

Order Numbers

2011

Expert™ 1400, range 0 - 0,3 mWG

2016

Expert™ 1400, range 0 - 30 mWG

2012

Expert™ 1400, range 0 - 1 mWG

2017

Expert™ 1400, range 0 - 100 mWG

201

Expert™ 1400, range 0 - 3 mWG

2018

Expert™ 1400, range 0 - 300 mWG

2014

Expert™ 1400, range 0 - 5 mWG

20225

Expert™ 1400, special meas. range

2015

Expert™ 1400, range 0 - 10 mWG

All 1400 transmitters are Atex approved.

Содержание 202925

Страница 1: ...l 45 45 56 06 56 Fax 45 45 56 06 46 mjk mjk com www mjk com As our products are continuously improved we reserve the right to make any change in the stated specifications and dimensions without prior...

Страница 2: ...ct complies with the requirements concerning electromagnetic compatibility EMC stipulated in Council directive no 89 336 EEC of 3rd May 1989 altered at directive no 92 31 EEC on the approximation of t...

Страница 3: ...air 4 Mechanical mounting 5 Model 1400 5 Model 3400 5 Model 3400 with thread top 5 Electrical mounting 6 Cable length vs supply voltage 6 Designation of wires cutting stripping the cable 6 Explosion h...

Страница 4: ...s are printed on a label on the transmitter housing For all versions the pressure range is indicated on the label Safety instructions 1 Read this manual carefully 2 Be aware of the environment on the...

Страница 5: ...itting by sliding the two plastic jaws upwards place the cable between the jaws and slide the jaws downwards until the cable locks Secure the cable fitting by pulling the cable downwards 3 Lower the p...

Страница 6: ...transmitter or make any attemt to program the tranmitter while the transmitter is located in an explosion hazardous zone Electrical mounting Cable length vs supply voltage The cable can be lengthened...

Страница 7: ...r The Z788 Zener Barrier MJK part no 202995 has a safety fuse which will blow if the current exceeds the limit The voltage protection in the Zener barrier contains a number of zener diodes which are c...

Страница 8: ...ength Cmax Ci Ccable 129 m Cable length based of the inductance Max cable length Lmax Li Lcable 2862 m In this case the capacitance sets the limit of the cable length to 129 m If another approved isol...

Страница 9: ...ur or mists Equipment category Explosive gas air mixtures G Category 1 Zone 0 1 or 2 Category 2 Zone 1 or 2 Category 3 Zone 2 Designation of explosion protection EEx ia IIC T6 Electrical apparatus wit...

Страница 10: ...02993 the max cable length is 129 m Using The Z788 Zener Barrier MJK Order no 202995 the max cable length is 99 m Alternatively other cable types with equivalent specifica tions may be used If a cable...

Страница 11: ...mechanical parameters 4 Install the device only in media for which the wetted materials have sufficient durability 5 Expert transmitter type 1400 3400 hydrostatics level transmitter may not be used i...

Страница 12: ...tter than 0 2 FS 0 2 FS Measurement accuracy Better than 0 1 FS 10 to 30 C Better than 0 2 FS full temperature range Long time stability Better than 0 1 FS per year Materials Housing stainless steel A...

Страница 13: ...op 203955 Expert 3400 range 0 10 mWG 203963 Expert 3400 range 0 3 m 1 RG top 203956 Expert 3400 range 0 30 mWG 202925 Expert 3400 w special meas range MJK Expert 3400 Hydrostatic Level Transmitter Nom...

Страница 14: ...14 Manual Manual Expert 1400 3400 GB 0704 MJK Automation A S Byageren 7 DK 2850 Naerum Denmark Tel 45 45 56 06 56 Fax 45 45 56 06 46 mjk mjk com www mjk com This page intentionally left blank...

Страница 15: ...15 Manual Manual Expert 1400 3400 GB 0704 MJK Automation A S Byageren 7 DK 2850 Naerum Denmark Tel 45 45 56 06 56 Fax 45 45 56 06 46 mjk mjk com www mjk com This page intentionally left blank...

Страница 16: ...16 Manual Manual Expert 1400 3400 GB 0704 MJK Automation A S Byageren 7 DK 2850 Naerum Denmark Tel 45 45 56 06 56 Fax 45 45 56 06 46 mjk mjk com www mjk com...

Отзывы: