BEAM SPOT WASH (3IN1)                                                350W 

                  

BEAM SPOT WASH (3IN1)                                                350W

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Note: Care should be taken to ensure that none of the pins touch the metallic body of 
the plug or each other. The body of the plug is not connected in any way. The XLED 
590 accepts digital control signals in protocol DMX512 (1990). 
Connect the controller’s output to the first fixture’s input, and connect the first fixture’s 
output to the second fixture’s input and connect the rest fixtures in the same way. 
Eventually connect the last fixture’s output to a DMX terminator as shown in the figure 
below. 

 

DMX Terminator: 

In the Controller mode, at the last fixture in the chain, the DMX output has to be 
connected with a DMX terminator. This prevents electrical noise from disturbing and 
corrupting the DMX control signals. 

The  DMX  terminator  is  simply  an  XLR  connector  with  a  120Ω  (ohm)  resistor 

connected across pins 2 and 3, which is then plugged into the output socket on the 
last projector in the chain. The connections are illustrated below. 
 

 

 

                                                                             

Channel List:

 

Channel 

Function 

Value 

Effect 

CH1 

Pan 

0-255 

0--540° 

 

CH2 

Tilt 

0-255 

0--270° 

CH3 

Pan Fine tune 

0-255 

0--2.1° 

CH4 

Tilt Fine tune 

0-255 

0--1.0° 

CH5 

P/T speed adjustment 

0-255 

fast---SLOW 

CH6 

Frost 

0-255 

turn off--open 

CH7 

Dimming 

0-255 

Dimming0%--Dimming100% 

CH8 

Strobe 

0-10 

The shutter is closed 

11 

Slow strobe 

…… 

…… 

250 

Fast strobe 

251-255 

The shutter is open 

CH9 

Colour 

0-4 

White light 

5-9 

Colour1 

10-14 

Colour2 

15-19 

Colour3 

20-24 

Colour4 

25-29 

Colour5 

30-34 

Colour6 

35-39 

Colour7 

40-44 

Colour8 

45-49 

Colour9 

50-54 

Colour10 

55-59 

Colour11 

60-64 

Colour12 

65-69 

Colour13 

 

                                                                            

 

                              

  11 

Содержание MJ-1350N

Страница 1: ...H 3IN1 MJ 1350N User manual PROFESSIONAL STAGE LIGHTING Thank you for choosing our moving head light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Страница 2: ......

Страница 3: ...roduct improvement about our company the policy in this instruction booklet carries the data will have the possibility to be able to change in the future when no longer separate notice change matters concerned Our company retains when the product improvement changes the related specification the authority Technical Parameters Voltage AC100 240V 50 60Hz Power consumption 540W 220V Lamp YODN MSD 350...

Страница 4: ... section The lamp used in this projector is a discharge lamp After switching off don t attempt to restart the projector until lamp has cooled this will require approx 15 minutes Switching the lamp on and off at short intervals will reduce the life of both the lamp and the projector But occasional breaks will prolong the life of the lamp and projector Never run the projector without a lamp The ligh...

Страница 5: ... times of lamp through Insurance hole for auxiliary hanging 4 Don t use the handle of the moving head light to fixed or lift Fitting The Lamp Loosen 4 fast fit screws and remove the back cover when fitting replacing the lamp Do not touch the bulb of the new lamp with bare hand so as not to influence the beam output Do not harm the sticking out point of the lamp during its installation Fit new lamp...

Страница 6: ...ctor is correctly earthed and the electrical installation conforms to all relevant standards DMX Connection Connection between the controller and a projector and between one projector and another must be made with a 2 core screened cable with each core having at least a 0 5mm diameter Connection to and from the projector is via cannon 3 pin which are included with the projector XLR plugs and socke...

Страница 7: ...r This prevents electrical noise from disturbing and corrupting the DMX control signals The DMX terminator is simply an XLR connector with a 120Ω ohm resistor connected across pins 2 and 3 which is then plugged into the output socket on the last projector in the chain The connections are illustrated below 4 Channel List Channel Function Value Effect CH1 Pan 0 255 0 540 CH2 Tilt 0 255 0 270 CH3 Pan...

Страница 8: ...ge choice 180 Screen rotation 5 DMX ERR 001 Setting Manual Info System 中 EN 180 Lock ESCAPE NEXT PREV ENTEN Trouble Shooting Problem Answer The moving head light doesn t switch on Check the fuse the power socket Replace the lamp Although shines but the moving head lamp doesn t accept the instruction of the controller Check the digital start address and also check the connection situation of the co...

Страница 9: ...e To prolong the life of the projector some maintenance work has to be done to ensure the optical system in good condition If the projector does not function check the fuses on the power socket of the projector they should only be replaced by fuses of the same specification Should these be damaged call a qualified technician before replacement The projector has thermal protection device that will ...

Страница 10: ...annel value Thereby entering the sub interface displaying the channel values in values and percentages for viewing System error record If the red ERR indicator light is lit indicating that the lights run error the details can be entered into the sub interface view After viewing press Clear to clear the error log Note sometimes not really Hall or optocoupler installation problems but the motor line...

Отзывы: