SAFE USAGE OF THE PRODUCT 

 

When unpacking and before disposing of the carton, check there is no transportation damage before 
using the product. Should there be any damage caused by transportation, consult your dealer and do 
not use the apparatus. 
The product is for indoor use only, IP20. Use only in dry locations. Keep this device away from rain 
and moisture, excessive heat, humidity and dust. Do not allow contact with water or any other 
liquids. 
The product is not designed or intended to be mounted directly on to inflammable surfaces 
The product is only intended for installation, operation and maintenance by professional person. 
The  product  must be installed in a location with adequate ventilation, at least 50cm from adjacent 
wall surfaces. Be sure that no ventilation slots are blocked. 
Do not product the beam onto inflammable surfaces, minimum distance is 5m.

 

Avoid direct exposure to the light from the lamp. The light is harmful to the eye. 
Do not attempt to dismantle or modify the projector in any way. 
Electrical connection must only be carried out by qualified personnel. 
Before installation, ensure that the voltage and frequency of power supply match the power 
requirements of the projector.   
It is essential that each projector is correctly earthed and that electrical installation conforms to all 
relevant standards. 
Do not connect this device to any other types of dimmer apparatus. 
Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the 
power-cord come into contact with other cables. Only handle the power-cord by the plug. Never pull 
out the plug by tugging the power-cord. 
Keep the optical system clean. Do not touch the LED lens with bare hands. 
The product should always be installed with a secondary safety fixing. On the projector base brink, 
there is a hole for the safety cord provided. It should be attached as shown in “installing the projector” 
section. 
LED lens shall be changed if they have become visibly damaged to such an extent that their 

effectiveness is impaired, for example by cracks or deep scratches.

 

Exterior surface temperatures of the luminaire after 5 minutes operation is 40°C

when steady state is 

achieved 50°C. 
There is no user serviceable parts inside the projector, do not open the housing and never operate the 
product with the covers removed. 
If you have any questions, don’t hesitate to consult your dealer or manufacturer. 

 

Always disconnect from the mains, when the device is not in use or before cleaning it or 

before attempting any maintenance work ! 

Содержание MJ-1006B3

Страница 1: ...3 4IN1 User Manual PROFESSIONAL LED LIGHTING Thank you for choosing our LED zoom moving head light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Страница 2: ...ery unit is tested completely and packed properly by the manufacturer Please make sure the packing and the unit are in good condition before installation and use Should there be any damage caused by transportation consult your dealer and do not use the unit Any damage caused by improper use will not be assumed by the manufacturer or dealer Attention Unceasingly carries on the product improvement a...

Страница 3: ...h the power requirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cables Only handle the power cord by the...

Страница 4: ... the light Do not use clamp as a tool to move fixtures 2 Base on safety reason please use the safety cord which can afford the weight ten times of lamp through Insurance hole for auxiliary hanging 3 Don t use the handle of the moving head light to fixed or lift Power Code Connection Connect the power cord as follows L live brown E earth yellow green N neutral blue Use the plug provided to connect ...

Страница 5: ...nected as shown in the figure above Note Care should be taken to ensure that none of the pins touch the metallic body of the plug or each other The body of the plug is not connected in any way The XLED 590 accepts digital control signals in protocol DMX512 1990 Connect the controller s output to the first fixture s input and connect the first fixture s output to the second fixture s input and conn...

Страница 6: ...rojector in the chain The connections are illustrated below Function Set Touch Operation Picture 1 picture 2 Touch LCD into the main menu when the LCD is off When the LCD display the main menu touch the menu into sub menu as picture 1 Touch LCD display can set the address code and function code easily Set or browse function setting of lamp touch UP or DOWN buttons as picture 2 Touch OK key to save...

Страница 7: ...Auto6 OK CANCEL 0 255 0 255 0 255 0 255 0 255 0 255 White 1 0 255 Load Default OK CANCEL Channel Mode Pan Tilt Swap Invert Tilt 8 16 28CH ON OFF ON OFF No DMX Signal Dimmer Delay Pan Tilt Encoder KEEP CLEAR ON OFF DIM1 DIM2 DIM3 DIM4 OFF Display DMX address LOGO OFF Black Random Mode Back DMX Address set 0 255 Invert Pan ON OFF Manual Back Dimmer 0 255 ...

Страница 8: ...Master signal then it is running slave mode 2 Auto mode Auto mode also can be master mode It have 11 kinds of mode 3 Sound mode When the light in sound mode it can t be control by sound and master mode 4 Random Mode The light is running by random DMX Address after you finished the setting then you need to touch OK button to keep the address code and return to main menu Channel Mode It can choose t...

Страница 9: ...d 1 setting by hand Green 1 Green 1 setting by hand Blue 1 Blue 1 setting by hand White 1 White 1 setting by hand Red 2 Red 2 setting by hand Green 2 Green 2 setting by hand Blue 2 Blue 2 setting by hand White 2 White 2 setting by hand Red 3 Red 3 setting by hand Green 3 Green 3 setting by hand Blue 3 Blue 3 setting by hand White 3 White 3 setting by hand 3 System display related information on sy...

Страница 10: ...perates damp smoke or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics A soft cloth and typical glass cleaning products should be used for cleaning It is recommended to clean the external optics at least once every 15 days Do not use any organic solvent e g alcohol to clean housing of the apparatus Trouble Shooting Problem Answer The LED moving head light...

Страница 11: ...0 255 X Y motor speed from quick to slow CH 6 0 255 Main dimming CH 7 0 255 Red all dimmer CH 8 0 255 Green all dimmer CH 9 0 255 Blue all dimmer CH 10 0 255 White all dimmer CH 11 0 Off 1 255 Strobe from slow to quick CH 12 0 255 Color mixing CH 13 Macro 0 9 No function 10 19 Show 1 20 39 Show 2 40 59 Show 3 60 79 Show 4 80 99 Show 5 100 119 Show 6 120 139 Show 7 140 159 Show 8 160 179 Show 9 180...

Страница 12: ...39 Show 2 40 59 Show 3 60 79 Show 4 80 99 Show 5 100 119 Show 6 120 139 Show 7 140 159 Show 8 160 179 Show 9 180 199 Show 10 200 219 Show 11 220 239 Show 1 to Show 11 240 255 Sound CH 14 0 255 Macro speed from slowly to fast CH 15 0 255 Zoom CH 16 0 99 No function 100 255 Motor Reset after 5 second CH 17 0 255 Red 1 dimmer CH 18 0 255 Green 1 dimmer CH 19 0 255 Blue 1 dimmer CH 20 0 255 White 1 di...

Страница 13: ...ut single color Mixes the color strobe Head Movement Pan 540 Tilt 270 with auto position correction and electronic replacement function Zoom Angle 10 60 Control mode DMX 512 Stand alone mode Self test mode Sound Master slave DMX Channel 8 16 28CH Control Panel Touch LCD display panel IP Grade IP20 Work Environment Temperature 20 C 40 C Other Functions Pan and Tilt speed adjustable LCD Display and ...

Отзывы: