IPB-5000A
6. Discription of Display Screens
6-1
6. Description of Display Screens
(1) Operation Flow
An example of the operation for the use of Welding Power Supply is shown as
follows:
1. Start up
IPB-5000A
2. Press
MENU Key
in the front panel to display
MENU Screen
3. Move the cursor
( )
to
SCHEDULE Key
in
MENU Screen
and press
ENTER
Key
to display
SCHEDULE Screen
4.Select a desired control method among
Constant Current Control
,
Constant Voltage Control
,
Constant Current/Constant Voltage
Combination Control
and
Constant Power Control
(See
(8)
①
(b)CONTROL
)
5. Set each value of the followings
(
SCH #
,
TIME
,
UP SLOPE
,
DOWN SLOPE
,
WE1
,
WE2
,
TR #
)
6. Supply the current for welding (e.g. close Pin No.5 at
External Interface
in
8.(1)
①
)
7. Display monitored
CURR
,
VOLT
,
POWER
and
RESIST
for verifying weld (See
(4)MONITOR Screen
)
8. Selection of Judgement Function
Set the upper and lower
limit of
CURR
,
VOLT
,
POWER
and
RESIST
for
judging Good or No Good
of weld
(See
(5)COMPARATOR
Screen
)
Set Envelope Waveform
for judging Good or No
Good of weld
(See
(6)ENVELOPE
Screen
)
Set Weld Time and
Control Voltage for
Precheck Current Supply
(See
(7)PRECHECK
Screen
)
9. Supply the current for welding
10. Stop
IPB-5000A