2.8  Spec 

Transmission/Reception Frequencies :  unit [ MHz ] 

 

ch 

Freq. 

ch 

Freq. 

2402 

20 

2442 

2404 

21 

2444 

2406 

22 

2446 

2408 

23 

2448 

2410 

24 

2450 

2412 

25 

2453 

2414 

26 

2454 

2416 

27 

2456 

2418 

28 

2458 

2420 

29 

2460 

10 

2422 

30 

2462 

11 

2424 

31 

2464 

12 

2426 

32 

2466 

13 

2428 

33 

2468 

14 

2430 

34 

2470 

15 

2432 

35 

2472 

16 

2434 

36 

2474 

17 

2436 

37 

2476 

18 

2438 

38 

2478 

19 

2440 

39 

2480 

 

 

Transmission power

at each antenna connector

 unit [ dBm ] TYP. 

 

ch 

Freq. 

 

ch 

Freq. 

 

2402 

3.0 

20 

2442 

3.0 

2404 

3.0 

21 

2444 

3.0 

2406 

3.0 

22 

2446 

3.0 

2408 

3.0 

23 

2448 

3.0 

2410 

3.0 

24 

2450 

3.0 

2412 

3.0 

25 

2453 

3.0 

2414 

3.0 

26 

2454 

3.0 

2416 

3.0 

27 

2456 

3.0 

2418 

3.0 

28 

2458 

3.0 

2420 

3.0 

29 

2460 

3.0 

10 

2422 

3.0 

30 

2462 

3.0 

11 

2424 

3.0 

31 

2464 

3.0 

12 

2426 

3.0 

32 

2466 

3.0 

13 

2428 

3.0 

33 

2468 

3.0 

14 

2430 

3.0 

34 

2470 

3.0 

15 

2432 

3.0 

35 

2472 

3.0 

16 

2434 

3.0 

36 

2474 

3.0 

17 

2436 

3.0 

37 

2476 

3.0 

18 

2438 

3.0 

38 

2478 

3.0 

19 

2440 

3.0 

39 

2480 

3.0 

 
 

Содержание WML-C103

Страница 1: ...er could void the authority to operate in these regions Content 1 General 2 Description 3 FCC Regulatory Information 4 Canada Industrie Canada IC 1 General This Bluetooth LE module has to be installed...

Страница 2: ...Ver5 0 Host Interface UART Frequency 2402 2480MHz World Wide RF Channel band 2MHz RF Channel number 40ch Data Rate 1Mbps Output Power 7 dBm MAX Sensitivity 84dBm Supply Voltage 3 0V 0 3V Current Consu...

Страница 3: ..._Manual 26 Jun 2018 COMMERCIAL IN CONFIDENCE This material may not in whole or part be copied stored electronically or communicated to third parties without MITSUMI ELECTRIC CO LTD s prior agreement i...

Страница 4: ...1 2464 12 2426 32 2466 13 2428 33 2468 14 2430 34 2470 15 2432 35 2472 16 2434 36 2474 17 2436 37 2476 18 2438 38 2478 19 2440 39 2480 Transmission power at each antenna connector unit dBm TYP ch Freq...

Страница 5: ...don t place any solid GND and line on below blue line s area with the exception of SMT land for this module 2 Because red line s area is the antenna it should be put on your PCB material 3 Please don...

Страница 6: ...copied stored electronically or communicated to third parties without MITSUMI ELECTRIC CO LTD s prior agreement in writing 2 10 Recommended Reflow Condition 1 Pre heat 170 190 degree 60 120sec 2 Peek...

Страница 7: ...thority to operate the equipment This transmitter must not be co located or operated in conjunction with any other antenna or transmitter This equipment complies with FCC radiation exposure limits set...

Страница 8: ...eil ne doit pas produire de brouillage 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement This e...

Отзывы: