background image

– 7 –

Operation and indication section for remote control

Operation section

FAN SPEED button

Each time the button is pushed, the

 indi-

cator is switched over in turn.

The above illustration shows all controls, but in practice
only the relevant parts are shown.

OPERATION MODE select button

Each time the button is pushed, the

 indi-

cator is switched over in turn.

ALLERGEN CLEAR button

This button selects ALLERGEN CLEAR
operation.

 Page 14

ON/OFF (luminous) button

Press for starting operation, press again for
stopping.

HI POWER/ECONO button

This button changes the HIGH POWER/
ECONOMY mode.

 Page 14

AIR FLOW (UP/DOWN) button

This button changes the air flow (up/down) mode.

 Page 10

TIME SET UP switch

This switch for setting the time.

 Page 13

SLEEP button

This button changes to SLEEP operation.

 Page 11

CLEAN switch

This switch changes the CLEAN mode.

 Page 15

ON TIMER button

This button selects ON TIMER operation.

 Page 12

AIR FLOW (LEFT/RIGHT) button

This button changes the air flow (left/right) mode.

 Page 10

CANCEL button

This button cancels the ON timer, OFF
timer, and SLEEP operation.

RESET switch

Switch for resetting microcomputer.

 Page 16

Indication section

TEMPERATURE indicator

Indicates set temperature.
(Does not indicate temperature when operation
mode is on AUTO)

FAN SPEED indicator

Indicates set air flow rate with

 lamp.

ALLERGEN CLEAR indicator

Indicates during ALLERGEN CLEAR operation.

SLEEP indicator

Indicates during SLEEP operation.

ON/OFF TIMER indicator

Indicates during ON/OFF TIMER operation.

CLEAN indicator

Indicates during CLEAN operation.

AIR FLOW indicator

Shows selected flap and louver mode.

HI POWER/ECONO MODE indicator

Indicates during HIGH POWER/ECONOMY
mode operation.

Transmission procedure

When each button on the remote control is pressed – with the remote control pointing towards the air-conditioner unit – a signal is transmitted.
When the air-conditioner receives the signal correctly, it will beep.

OPERATION MODE indicator

Indicates selected operation with

 lamp.

(Auto) • 

(Cool) • 

 (Heat) •  (Dry) • 

(Fan)]

OFF TIMER button

This button selects OFF TIMER operation.

 Page 11

TEMPERATURE button

This button sets the room temperature.
(This button changes the present time and
TIMER time.)

TIME indicator

Indicates present time or timer setting time.

RKW012A212_En.p65

11/3/05, 9:14 AM

7

Black

Содержание SRK63ZE-S1

Страница 1: ...9 336 EEC LV erfüllt die EMC Direktiven 89 336 EEC LV C re d aria è conforme alla Direttiva EMC 89 a 73 23 EEC Deze airconditioner voldoet aan EMC Directive 89 336 EEC LV Directive 73 23 EEC Este acondicionador de aire cumple con la directiva EMC 89 336 EEC LV Directiva 73 23 EEC Este aparelho de ar condicionado está em conformidade com a Directiva EMC 88 336 CEE e a Directiva LV 72 23 CEE Ùfi ÙÔ Î...

Страница 2: ...eration procedure 8 Temperature adjustment during AUTO 8 About FAN SPEED 8 COOL HEAT DRY FAN mode operation procedure 9 Air conditioner operating conditions 9 Characteristics of HEAT mode operation 9 Air flow direction adjustment procedure 10 SLEEP operation procedure 11 OFF TIMER operation procedure 11 ON TIMER operation procedure 12 SLEEP operation ON TIMER operation procedure 12 PROGRAM TIMER o...

Страница 3: ...cable may produce an electric shock Depending on the place of installation a circuit breaker may be necessary If you don t fit a circuit breaker you may cause an electric shock Do not install near places where inflammable gas may leak Gas leaks may cause fire Make sure that you drain the hose properly so that all the water has dripped out Negligence may cause flooding in the room resulting in wet ...

Страница 4: ...a combustible insecticide or paint spray near the blower nor aim it directly at the system This may result in a fire Do not place anything containing wa ter like vases on top of the unit Water entering the unit could damage the insula tion and therefore cause an electric shock The system should only be used for its original purpose and not for anything else like for instance preservation of food p...

Страница 5: ...or SLEEP ON and OFF They can be set as desired Page 13 When using the timer to switch on the sys tem should become operational shortly be fore the set time depending on the room temperature so that the desired temperature should be reached at the set time Amenity facility TIMER procedure MULTI DIRECTIONAL AIR FLOW This function sets the unit at the most suitable angle for blowing imitating a natur...

Страница 6: ... control Drain hose Drains water from the dehumidified air Left right air flow adjustment fin Page 10 Up down air flow direction adjustment flap Page 10 Air outlet Air blows out of here Unit operation switch Room temperature detector Allergen clear filter Accessories Wireless remote control Battery R03 2 Allergen clear filter Light orange Photocatalytic washable deodorizing filter Orange Wood scre...

Страница 7: ...air inlet panel for internal cleaning or others open the panel by 80 degrees and then pull it to this side In emergencies this button can be used for turning on off the unit when re mote control is not available Page 15 Removal installation of air inlet panel ECONO light orange Illuminates during ECONOMY operation HI POWER light green Illuminates during HIGH POWER operation RUN HOT KEEP light gree...

Страница 8: ...n cancels the ON timer OFF timer and SLEEP operation RESET switch Switch for resetting microcomputer Page 16 Indication section TEMPERATURE indicator Indicates set temperature Does not indicate temperature when operation mode is on AUTO FAN SPEED indicator Indicates set air flow rate with lamp ALLERGEN CLEAR indicator Indicates during ALLERGEN CLEAR operation SLEEP indicator Indicates during SLEEP...

Страница 9: ...s in the following order 6 5 1 0 1 6 When 6 is indicated even if the button is pressed the indicator does not change Each time the button is pressed the switch over occurs in the following order 6 5 1 0 1 6 When 6 is indicated even if the button is pressed the indicator does not change When the unit is not in AUTO mode Press MODE button Move the mark to the Auto position Aim the remote control at ...

Страница 10: ... may result in condensation forming on the surface of the indoor unit leading to water drips Characteristics of HEAT mode operation Mechanism and capacity of HEAT mode operation Mechanism The unit draws in heat from the cold outside air transfers it indoors and heats the room The heating capacity of the heat pump mechanism decreases when the outside air temperature gets colder The hot air circulat...

Страница 11: ...topped Swing Multi directional Air Flow up down air scroll and left right air scroll Activating both up down air swing and left right air swing at the same time results in a multi directional air flow Up down air scroll Left right air scroll Thick line moves quickly Thin line moves slowly Stops at this position for 5 seconds Stops at this position for 5 seconds In COOL DRY and FAN operation In HEA...

Страница 12: ... 1 10 Each time the button is pressed the indicator is switched in the order of 0 00 23 50 23 40 Units of ten minutes 23 00 22 50 Set at 22 30 3 The unit stops automatically at the end of the set period of time If it is stopped perform the operations starting with STEP 1 and if running start with STEP 2 Changing of set time Set to a new time by using SLEEP button SLEEP operation procedure The unit...

Страница 13: ...to ON TIMER operation setting Set by the above mentioned ON TIMER operation procedure Set to The setting of the lighting of the timer light yellow of this unit is complete h After the SLEEP operation set time has elapsed the operation stops and it starts from 5 to 60 minutes before the ON TIMER s time The timer light is not lit at the ON TIMER s time Changing of set time Set a new time by using th...

Страница 14: ... The timer operation is set on the basis of the present time so please set it correctly 1 3 Changing of set time Set a new time by using the OFF TIMER or ON TIMER button About Amenity facilities Amenity facilities enable to start the operation a little earlier so that the room should approach optimum temperature at ON time when the operation is started by ON TIMER Mechanism The room temperature is...

Страница 15: ...n the operation mode is changed 3 When it has been 15 min since HIGH POWER operation has started Concerning ECONOMY operation Pressing the HI POWER ECONO button intlates a soft operation with the power suppressed in order to avoid an excessive cooling or heating The unit operates 1 5 C higher than the setting temperature for weak wind capacity during cooling or 2 5 C lower than that during heating...

Страница 16: ...mote control is not used Operation program OPERATION MODE AUTO FAN SPEED AUTO AIR FLOW AUTO Operation starts by pressing the unit ON OFF button it stops if you press the button again Unit ON OFF button Power blackout auto restart function What is power blackout auto restart function Power blackout auto restart function is a function that records the operational status of the air conditioner immedi...

Страница 17: ...the reset switch with the tip of a ballpoint pen 1 2 3 Attention to the and marks Press the reset switch with the tip of a ballpoint pen 4 Are the batteries running down Replacing the batteries above Replace the batteries with new ones and repeat the operation Don t drop the remote control Handle with care Don t go near high temperature places such as an electric carpet or stove Do not place heavy...

Страница 18: ...l is once every two week Don t use the following articles Hot water 40 C or more It may deform or discolour the unit Petrol paint thinner benzine or polishing agents etc They may deform or scratch the unit Don t spill water Do not touch the aluminum fins on the heat exchanger Stand firmly on a stepladder or other stable object when removing the inlet panel and filter Cleaning If the filter is very...

Страница 19: ... dirt from the allergen clear filter Replace the allergen clear filter if it cannot be cleaned or if it has been for about 1 year The allergen clear filter should be replaced after about 1 year of use However the actual replacement period may vary depending on the conditions in which the filter is used Remove the photocatalytic washable deodorizing filter from the filter holder and inspect the fil...

Страница 20: ...ecial purpose tools are required Suitable installation position Is there any obstruction in front of the indoor unit preventing proper ventilation and functioning Don t install the unit in any of the following places Where there is a danger of leaking inflammable gases Where there is substantial splashing of oil Malfunctioning due to corrosion may occur if the unit is installed in a spa where sulf...

Страница 21: ...n to protect the unit The three minute protection timer in the microcomputer automatically starts up again Please wait for three minutes If the unit is operated for a long time in high humidity moisture may form on the air outlet grills and start dripping You hear a slight gurgling sound This is caused by refrigerating liquid moving within the unit You hear a slight cracking sound This is caused b...

Страница 22: ... starts to malfunction When faulty movement is observed when the ON OFF but ton is pressed even after turning off the power switch and restarting the operation after 3 minutes the faulty move ment does not disappear A switch does not activate properly You hear a strange noise during opera tion 3 minutes go by but why Fuse often blows The RUN and TIMER lights on the unit indication section blink qu...

Страница 23: ......

Отзывы: