Mitsubishi SRK52CF-BN Скачать руководство пользователя страница 23

– 22 –

Specifications

Notes (1) The data are measured at the following conditions.

(2) The operation data are applied to the 220/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7m connecting piping.

(Purging is not required even in the short piping.)

If the piping length is longer, when it is 7 to 25m add 25g refrigerant per meter.

Outdoor air temperature

Indoor air temperature

DB

35

°

C

46

°

C

WB

24

°

C

24

°

C

Standards

ISO-T1, JIS C9612

ISO-T3, SASO 385/386

WB

19

°

C

19

°

C

DB

27

°

C

29

°

C

Item

Operation

Cooling

The piping length is 7.5m.

Indoor unit

Outdoor unit

  SRK52CF-BN(Indoor unit)

SRC52CF-BN(Outdoor unit)

SRK71CF-BN(Indoor unit)

SRC71CF-BN(Outdoor unit)

Split type room air-conditioner

1 Phase 220-240V 50Hz

Model name

15

Item

Type

Power supply

Performance

Cooling capacity

Cooling power input

Energy efficiency ratio

Rating current

Cooling capacity

Cooling power input

Energy efficiency ratio

Rating current

Unit dimension

New wight

Refrigerant

Country of origin

V

kW

kW

Btu/hW

A

kW

kW

Btu/hW

A

mm

mm

Kg

Kg

Kg

220

5.4

1.76

10.47

8.8

5.0

2.06

8.29

10.3

240

5.4

1.91

9.66

8.7

5.0

2.20

7.75

10.1

220

7.03

2.12

11.33

10.6

6.3

2.48

8.67

12.4

240

7.03

2.27

10.58

10.4

6.3

2.60

8.26

11.9

640 

×

 850 

×

 290

46

R22 1.25

750 

×

 880 

×

 340

67

R22 1.75

Indoor unit

Outdoor unit

Thailand

318 

×

 1098 

×

 248

ISO-T3(SASO)

ISO-T1(JIS)

Indoor unit

Outdoor unit

Model name

15

Item

Type

Power supply

Performance

Cooling capacity

Cooling power input

Energy efficiency ratio

Rating current

Cooling capacity

Cooling power input

Energy efficiency ratio

Rating current

Unit dimension

New wight

Refrigerant

Country of origin

V

kW

kW

Btu/hW

A

kW

kW

Btu/hW

A

mm

mm

Kg

Kg

Kg

220

5.4

1.76

10.47

8.8

5.0

2.06

8.29

10.3

220

7.03

2.12

11.33

10.6

6.3

2.48

8.67

12.4

640 

×

 850 

×

 290

46

R22 1.25

750 

×

 880 

×

 340

67

R22 1.75

Indoor unit

Outdoor unit

Thailand

318 

×

 1098 

×

 248

ISO-T3(SASO)

ISO-T1(JIS)

Split type room air-conditioner

1 Phase 220V 60Hz

SRK71CF-BP(Indoor unit)

SRC71CF-BP(Outdoor unit)

  SRK52CF-BP(Indoor unit)

SRC52CF-BP(Outdoor unit)

RKW012A217_En.p65

06.8.3, 1:57 PM

22

Содержание SRK52CF-BN

Страница 1: ...RKW012A217 ENGLISH N N USER S MANUAL AIR CONDITIONER SRK52CF BP SRK71CF BP...

Страница 2: ...UTO 8 About FAN SPEED 8 COOL DRY FAN mode operation procedure 9 Air conditioner operating conditions 9 Air flow direction adjustment procedure 10 SLEEP operation procedure 11 OFF TIMER operation proce...

Страница 3: ...able may produce an electric shock Depending on the place of installation a circuit breaker may be necessary If you don t fit a circuit breaker you may cause an electric shock Do not install near plac...

Страница 4: ...combustible insecticide or paint spray near the blower nor aim it directly at the system This may result in a fire Do not place anything containing wa ter like vases on top of the unit Water entering...

Страница 5: ...red Page 13 When using the timer to switch on the sys tem should become operational shortly be fore the set time depending on the room temperature so that the desired temperature should be reached at...

Страница 6: ...air flow adjustment louver Page 10 Up down air flow direction adjustment flap Page 10 Air outlet Air blows out of here Unit operation switch Room temperature detector Natural enzyme filter Accessories...

Страница 7: ...the air inlet panel for internal cleaning or others open the panel by 80 degrees and then pull it to this side In emergencies this button can be used for turning on off the unit when re mote control i...

Страница 8: ...ancels the ON timer OFF timer and SLEEP operation RESET switch Switch for resetting microcomputer Page 16 Indication section TEMPERATURE indicator Indicates set temperature Does not indicate temperatu...

Страница 9: ...over occurs in the following order 6 5 1 0 1 6 When 6 is indicated even if the button is pressed the indicator does not change Each time the button is pressed the switch over occurs in the following o...

Страница 10: ...op Press the ON OFF button Air is not blown out during the operation Page 20 NOTE 2 1 Air conditioner operating conditions Use within the following operational range Operating outside of this range ma...

Страница 11: ...l Thick line moves quickly Thin line moves slowly Stops at this position for 5 seconds In COOL DRY and FAN operation MEMORY FLAP FLAP OR LOUVER STOPPED When you press the AIRFLOW UP DOWN or LEFT RIGHT...

Страница 12: ...minutes 1 00 1 10 Each time the button is pressed the indicator is switched in the order of 0 00 23 50 23 40 Units of ten minutes 23 00 22 50 Set at 22 30 3 The unit stops automatically at the end of...

Страница 13: ...o ON TIMER operation setting Set by the above mentioned ON TIMER operation procedure Set to The setting of the lighting of the timer light yellow of this unit is complete h After the SLEEP operation s...

Страница 14: ...on Set to 10 30 Press the TIME SET UP switch The indication changes from blinking to steady lighting and the setting is complete The timer operation is set on the basis of the present time so please s...

Страница 15: ...is not available during the DRY and the PROGRAM TIMER operations During ON timer operation HIGH POWER operation will start when the ON time is reached When the following operations are conducted HIGH...

Страница 16: ...t used Operation program OPERATION MODE AUTO FAN SPEED AUTO AIR FLOW AUTO Operation starts by pressing the unit ON OFF button it stops if you press the button again Unit ON OFF button Power blackout a...

Страница 17: ...the reset switch with the tip of a ballpoint pen 1 2 3 Attention to the and marks Press the reset switch with the tip of a ballpoint pen 4 Are the batteries running down Replacing the batteries above...

Страница 18: ...once every two week Don t use the following articles Hot water 40 C or more It may deform or discolour the unit Petrol paint thinner benzine or polishing agents etc They may deform or scratch the unit...

Страница 19: ...e cleaned or if it has been for about 1 year The natural enzyme filter should be replaced after about 1 year of use However the actual replacement period may vary depending on the conditions in which...

Страница 20: ...y be replaced by a repair shop appointed by the manufacturer because special purpose tools are required Suitable installation position Is there any obstruction in front of the indoor unit preventing p...

Страница 21: ...air outlet grilles and start dripping You hear a slight gurgling sound This is caused by refrigerating liquid moving within the unit You hear a slight cracking sound This is caused by heat expansion o...

Страница 22: ...aler or a qualified engineer to install the replacement to avoid accidents Outdoor heat exchanger sensor error Outdoor temperature sensor error Broken outdoor sensor wire poor connector connection Des...

Страница 23: ...rgy efficiency ratio Rating current Unit dimension New wight Refrigerant Country of origin V kW kW Btu hW A kW kW Btu hW A mm mm Kg Kg Kg 220 5 4 1 76 10 47 8 8 5 0 2 06 8 29 10 3 240 5 4 1 91 9 66 8...

Страница 24: ......

Отзывы: