background image

– 6 –

Unit indication section

How to open the air inlet panel

How to close the air inlet panel

Push both sides evenly and press further lightly at the center.

Place fingers at the recesses on both sides of the panel and pull up the panel
to this side so that it will be opened by about 60 degrees.

Unit ON/OFF button

Secure either the upper or lower edge of the air inlet panel by lightly pushing
it in, and then close the panel.

When removing the air inlet panel for internal cleaning or others, open the
panel by 65 degrees and then pull it to this side.

In emergencies, this button can be used for turning on/off the unit when re-

mote control is not available.   

  Page 13

Removal, installation of air inlet panel

ECONOMY light (orange)

Illuminates during ECONOMY operation.

HI POWER light (green)

Illuminates during HIGH POWER operation.

RUN (HOT KEEP) light (green)

Illuminates during operation.

Blinks at air flow stop due to the ‘HOT KEEP’.

  Page 17

TIMER light (yellow)

Illuminates during TIMER operation.

Unit ON/OFF button

Installation
Align the air inlet top panel with the rail and slide the panel in towards
the back unitl it strikes the end. Push the panel in until you hear a click
and the tabs lock into place and the tabs lock into place.
(To install the air inlet top panel, follow the opposite of the removal
procedure.)

Removal
Remove the air inlet panel. 

1

 Grasp the handle of the air inlet top panel and lift up

until you hear a click and the tabs come out. 

2

 Pull the panel towards you.

Removal, installation of air inlet top panel

RKT012A754_En.p65

05.9.14, 1:42 PM

6

Содержание SRK50CE-S1

Страница 1: ...ctiva 73 23 EEC Este aparelho de ar condicionado est em conformidade com a Directiva EMC 88 336 CEE e a Directiva LV 72 23 CEE EMC 88 396 LV 73 23 USER S MANUAL AIR CONDITIONER RKT012A754 ENGLISH MANU...

Страница 2: ...EAT DRY FAN mode operation procedure 9 Concerning HIGH POWER operation 9 Concerning ECONOMY operation 9 Air flow direction adjustment procedure 10 About FAN SPEED 10 OFF TIMER operation procedure 11 O...

Страница 3: ...ble may produce an electric shock Depending on the place of installation a circuit breaker may be necessary If you don t fit a circuit breaker you may cause an electric shock Do not install near place...

Страница 4: ...combustible insecticide or paint spray near the blower nor aim it directly at the system This may result in a fire Do not place anything containing wa ter like vases on top of the unit Water entering...

Страница 5: ...when switched on Characteristics Amenity facility TIMER procedure HI POWER mode Page 12 When using the timer to switch on the sys tem become operational shortly before the set time depending on the ro...

Страница 6: ...deodorizing filter Natural enzyme filter Refrigerant piping connection electric flex Up down air flow direction adjustment flap Page 10 Wireless remote control Page 7 Drain hose Drains water from the...

Страница 7: ...ge 13 Removal installation of air inlet panel ECONOMY light orange Illuminates during ECONOMY operation HI POWER light green Illuminates during HIGH POWER operation RUN HOT KEEP light green Illuminate...

Страница 8: ...e 11 TEMPERATURE button This button sets the room temperature This button changes the present time and TIMER time CANCEL button This button cancels the ON timer and OFF timer RESERVE button This butto...

Страница 9: ...adjustment procedure Page 10 NOTE WARM Press the button COOL Press the button 1 When a change in temperature is desired Press the or button Air is not blowing out during the op eration Page 17 If you...

Страница 10: ...display is erased Concerning ECONOMY operation Pressing the ECONO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating The unit operates 1 5 C...

Страница 11: ...hen in COOL or DRY operation do not operate for hours on end with the air flow blowing straight down Otherwise condensation may appear on the outlet grill and drip down Do not try to adjust the flaps...

Страница 12: ...Releasing procedure Press the CANCEL button to turn off the timer indicator ON TIMER operation procedure 1 2 Changing of set time Set a new time by using the ON TIMER button Example In the case you w...

Страница 13: ...cator About TIMER operation About Amenity facilities Amenity facilities enable to start the operation a little earlier so that the room approaches optimum tempera ture at ON time when the operation is...

Страница 14: ...ttery conforming to JIS or IEC is 6 to 12 months with normal use If used longer or when an unspecified battery is used liquid may leak from the battery causing the remote control to malfunction Remove...

Страница 15: ...frequently Clogged filters may block the air flow and cause less efficient operation Don t go near high temperature places such as an electric carpet or stove Adjust the airflow direction properly Ad...

Страница 16: ...soft dry cloth There s a danger of electric shock Cleaning If the filter is very dirty clean it with warm water approx 30 C and dry it thoroughly CAUTION Don t clean the filters with boiling water Don...

Страница 17: ...the air filters 2 Remove the filter holders with the natural enzyme filter and the photocatalytic washable deodorizing filter installed in the holders from the air conditioner 3 Remove the natural enz...

Страница 18: ...restart the unit immediately after you have stopped it RUN light is on Not operating Air is not blown out when starting the HEATING operation RUN light blinks slowly 1 5 sec ON 0 5 sec OFF Air flow h...

Страница 19: ...he unit is operated for a long time in high humidity moisture may form on the air outlet grilles and start dripping You hear a slight gurgling sound This is caused by refrigerating liquid moving withi...

Страница 20: ...conditioner operating conditions Use within the following operational range Operating outside of this range may result in the protection devices being activated preventing the unit from working Coolin...

Страница 21: ...r sensor error 2 time flash 6 time flash TIMER light ON 1 time flash RUN light 2 time flash 1 time flash TIMER light RUN light keeps flashing Over heat of compressor Error of signal transmission 5 tim...

Страница 22: ......

Отзывы: