– 4 –

Choice of operations and features

Choice of operations

   Page 9

Drying by extracting damp from the room.

   Page 9

Cooling by extracting heat from the room.

COOL

DRY

   Page 9

The unit draws in heat from the outside air,
transfers it inside and heats the room.

HEAT

Functioning of micro-computer depends on
setting and room temperatures. It dehumidi-
fies while keeping room temperature almost
constant.

   Page 8

Automatic selection of operating mode.

   Page 9

Fanning by circulating room air.

The Auto mode automatically selects the
operation mode (HEAT, COOL or DRY),
depending on the room temperature when
switched on.

Characteristics

Amenity facility

TIMER procedure

HI POWER mode

   Page 12

When using the timer to switch on, the sys-
tem  become operational shortly before the
set time, depending on the room tempera-
ture so that the desired temperature is
reached at the set time.

   Page 11,12

There are two timers, for ON and OFF.
They can be set as desired.

   Page 9

Turning up the power operates the air-condi-
tioner in the power cooling and heating
mode.

   Page 10

Adjustment of

airflow

AIR SCROLL
This function sets the unit at the most suitable angle
for blowing, imitating a natural breeze.

MEMORY FLAP
Once the flap position has been set, the unit will
memorise it and  continue in the same position the
next time.

   Page 9

This is an economic and healthy level of op-
eration.

ECONOMY mode

AUTO

FAN

RKT012A754_En.p65

05.9.14, 1:42 PM

4

Содержание SRK50CE-S1

Страница 1: ...ctiva 73 23 EEC Este aparelho de ar condicionado est em conformidade com a Directiva EMC 88 336 CEE e a Directiva LV 72 23 CEE EMC 88 396 LV 73 23 USER S MANUAL AIR CONDITIONER RKT012A754 ENGLISH MANU...

Страница 2: ...EAT DRY FAN mode operation procedure 9 Concerning HIGH POWER operation 9 Concerning ECONOMY operation 9 Air flow direction adjustment procedure 10 About FAN SPEED 10 OFF TIMER operation procedure 11 O...

Страница 3: ...ble may produce an electric shock Depending on the place of installation a circuit breaker may be necessary If you don t fit a circuit breaker you may cause an electric shock Do not install near place...

Страница 4: ...combustible insecticide or paint spray near the blower nor aim it directly at the system This may result in a fire Do not place anything containing wa ter like vases on top of the unit Water entering...

Страница 5: ...when switched on Characteristics Amenity facility TIMER procedure HI POWER mode Page 12 When using the timer to switch on the sys tem become operational shortly before the set time depending on the ro...

Страница 6: ...deodorizing filter Natural enzyme filter Refrigerant piping connection electric flex Up down air flow direction adjustment flap Page 10 Wireless remote control Page 7 Drain hose Drains water from the...

Страница 7: ...ge 13 Removal installation of air inlet panel ECONOMY light orange Illuminates during ECONOMY operation HI POWER light green Illuminates during HIGH POWER operation RUN HOT KEEP light green Illuminate...

Страница 8: ...e 11 TEMPERATURE button This button sets the room temperature This button changes the present time and TIMER time CANCEL button This button cancels the ON timer and OFF timer RESERVE button This butto...

Страница 9: ...adjustment procedure Page 10 NOTE WARM Press the button COOL Press the button 1 When a change in temperature is desired Press the or button Air is not blowing out during the op eration Page 17 If you...

Страница 10: ...display is erased Concerning ECONOMY operation Pressing the ECONO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating The unit operates 1 5 C...

Страница 11: ...hen in COOL or DRY operation do not operate for hours on end with the air flow blowing straight down Otherwise condensation may appear on the outlet grill and drip down Do not try to adjust the flaps...

Страница 12: ...Releasing procedure Press the CANCEL button to turn off the timer indicator ON TIMER operation procedure 1 2 Changing of set time Set a new time by using the ON TIMER button Example In the case you w...

Страница 13: ...cator About TIMER operation About Amenity facilities Amenity facilities enable to start the operation a little earlier so that the room approaches optimum tempera ture at ON time when the operation is...

Страница 14: ...ttery conforming to JIS or IEC is 6 to 12 months with normal use If used longer or when an unspecified battery is used liquid may leak from the battery causing the remote control to malfunction Remove...

Страница 15: ...frequently Clogged filters may block the air flow and cause less efficient operation Don t go near high temperature places such as an electric carpet or stove Adjust the airflow direction properly Ad...

Страница 16: ...soft dry cloth There s a danger of electric shock Cleaning If the filter is very dirty clean it with warm water approx 30 C and dry it thoroughly CAUTION Don t clean the filters with boiling water Don...

Страница 17: ...the air filters 2 Remove the filter holders with the natural enzyme filter and the photocatalytic washable deodorizing filter installed in the holders from the air conditioner 3 Remove the natural enz...

Страница 18: ...restart the unit immediately after you have stopped it RUN light is on Not operating Air is not blown out when starting the HEATING operation RUN light blinks slowly 1 5 sec ON 0 5 sec OFF Air flow h...

Страница 19: ...he unit is operated for a long time in high humidity moisture may form on the air outlet grilles and start dripping You hear a slight gurgling sound This is caused by refrigerating liquid moving withi...

Страница 20: ...conditioner operating conditions Use within the following operational range Operating outside of this range may result in the protection devices being activated preventing the unit from working Coolin...

Страница 21: ...r sensor error 2 time flash 6 time flash TIMER light ON 1 time flash RUN light 2 time flash 1 time flash TIMER light RUN light keeps flashing Over heat of compressor Error of signal transmission 5 tim...

Страница 22: ......

Отзывы: