![Mitsubishi S6B3 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/mitsubishi/s6b3/s6b3_operation-and-maintenance-manual_1809142045.webp)
3-11
Chapter 3 OPERATION
Air Tank - Drain Water
1.
Open the drain valve slowly, and check that water
in the tank is drained from drain pipe.
2.
After water is drained and the air is discharged in
the tank, tighten the drain valve firmly.
3.
Loosen the drain handle on the bottom of drain
separator. Check that water in the drain separator
is discharged from the drain pipe.
4.
Close the drain handle after draining water firmly.
Note: If the specification of air tank differs from the
contents of this operation manual, follow the
manufacturer's operation manual.
Fig. 3-15 Air Tank - Drain Water
Air Tank Air Pressure - Check
1.
Check the air pressure gauge to see if the air pres-
sure in the air tank conforms to the standard.
2.
Open the air pressure gauge valve.
3.
Check air pressure in the air tank with air pressure
gauge.
Specified value:
For air direct starting: 2.94 MPa {30 kgf/cm
2
} [427
psi]
For air motor: 0.98 MPa {10 kgf/cm
2
} [142 psi]
4.
Close the air pressure gauge valve.
Note: If the specification of air tank differs from the
contents of this operation manual, follow the
manufacturer's operation manual.
Fig. 3-16 Starting Air Tank Air Pressure - Check
There are 2 places for draining water in the air tank:
drain valve on the top of air tank, and drain handle
on the bottom of drain separator.
Drain valve
Drain
separator
Drain
handle
Drain
pipe
Air pressure
gauge
Air pressure
gauge