Chapter 3 OPERATION
Air cleaner - Check
1.
Check the air cleaner indicator for the element
clog.
2.
If the element is clogged, the red signal mark is vis-
ible.
3.
Immediately clean or replace the air cleaner ele-
ment when the signal turns red.
4.
After checking, press the bottom on top of the indi-
cator to re-set the alarm signal.
Note: For cleaning of the air cleaner element, refer to
"Air cleaner element - Clean, Check and Re-
place" (8-17)
.
Fig. 3-20 Air cleaner - Check
Temperature of damper - Check
Damper temperature management by thermo label
It is recommended to use the thermo label for temper-
ature management of the damper. Check the thermo
label before starting engine.
1.
Check the thermal part of thermo label is black.
2.
Note the highest temperature of thermal part. Note
the temperature periodically, and check the abnor-
mality of temperature alteration.
Note: For damper inspection, refer to
"Damper - In-
spect" (8-3)
.
Fig. 3-21 Thermo label of damper
Reset
button
Signal
(red)
If the abnormality of temperature alteration is found,
consult a dealer of Mitsubishi Heavy Industries, Ltd.
<5E-75>
75
80
85
90
95
<5E-100>
100
105 110 115 120
<5E-50>
50
55
60
65
70
Thermo label
75ºC [167ºF]<Damper temperature
<80ºC [176ºF]