8
b) Wiring example with a voltage output type encoder (5VDC)
Encoder
A20(A13)
24 V
B20(B13)
12 V
A19(A12)
5 V
B19(B12)
ABCOM
Phase A
E
QD62-H01/H02
A18(A11)
24 V
B18(B11)
12 V
A17(A10)
5 V
Phase B
0 V
0 V
External
power
supply
Shield
Shielded twisted pair cable
E
GND
OUT
+5 V
5 V DC
GND
OUT
Shield
Shielded twisted pair cable
The terminal number in parentheses is for Channel 2.
2) Wiring example of a controller and an external input terminal
When the controller (sink loading type) is 12VDC:
B17(B10)
24 V
A16(A09)
12 V
B16(B09)
5 V
A15(A08)
CTRLCOM
Preset
OUT
E
+12 V
Controller
QD62-H01/H02
OUT
E
+12 V
12 V DC
B15(B08)
24 V
A14(A07)
12 V
B14(B07)
5 V
Function
start
Shield
Shielded twisted pair cable
Shield
Shielded twisted pair cable
The terminal number in parentheses is for Channel 2.