background image

A-2

[INSTALLATION PRECAUTIONS]

CAUTION

Do not bunch the control wires or communication cables with the main circuit 
or power wires, or install them close to each other.
They should be installed 100 mm (3.94 inch) or more from each other.
Not doing so could result in noise that may cause malfunction.

CAUTION

Use the programmable controller in the environment conditions given in the 
general specifications in the User's Manual for the CPU module. Failure to do 
so may cause an electric shock, fire, malfunction, or damage to or 
deterioration of the product.
While pressing the installation lever located at the bottom of the module, fully 
insert the module fixing projection into the fixing hole in the base unit to 
mount the module. Incorrect module mounting may cause a malfunction, 
failure, or drop of the module. In an environment of frequent vibrations or 
impacts, secure the module with screws.
The screws must be tightened within the specified torque range. If the screw 
is too loose, it may cause a drop or malfunction. Excessive tightening may 
damage the screw and/or the module, resulting in a drop or malfunction.
Be sure to shut off all phases of the external power supply used by the 
system before mounting or removing the module. Failure to do so may cause 
damage to the product.
Do not directly touch any conductive part or electronic part of the module.
Doing so may cause a malfunction or failure of the module.

Содержание Q68TD-G-H01

Страница 1: ...ogrammable controller MELSEC Q series 2007 MITSUBISHI ELECTRIC CORPORATION Channel Isolated Thermocouple Input Module Prior to use please read this and relevant manuals thorougly to fully understand t...

Страница 2: ...he precautions of both levels because they are important to personal safety Please keep this manual accessible when required and always forward it to the end user DESIGN PRECAUTIONS DANGER Do not writ...

Страница 3: ...ottom of the module fully insert the module fixing projection into the fixing hole in the base unit to mount the module Incorrect module mounting may cause a malfunction failure or drop of the module...

Страница 4: ...connected to the module in a duct or clamp them If not dangling cables may swing or inadvertently be pulled resulting in damage to the module and or cables or malfunctions due to poor cable connectio...

Страница 5: ...389 B Partly modified EMC and Low Voltage Directives Section 1 1 Chapter 2 Section 3 1 5 1 5 2 5 3 This manual confers no industrial property rights or any rights of any other kind nor does it confer...

Страница 6: ...PERFORMANCE SPECIFICATIONS 3 3 IMPLEMENTATION AND INSTALLATION 6 3 1 Handling Precautions 6 3 2 Installation Environment 6 4 PART NAMES 7 5 WIRING 9 5 1 Wiring Precautions 9 5 2 External Wiring 10 5...

Страница 7: ...ives compliant into other machinery or equipment refer to Chapter 9 EMC AND LOW VOLTAGE DIRECTIVES of the QCPU User s Manual Hardware Design Maintenance and Inspection The CE mark indicating complianc...

Страница 8: ...g describes the restrictions of the slot position when mounting the Q68TD G H01 with a combination of the power supply module and the base unit For the slot that the Q68TD G H01 cannot be mounted leav...

Страница 9: ...c Figure 1 3 Mountable slot position of Q68TD G H01 OUT I 01 I 01 CPU Slot No 0 Not mountable Mountable Power supply Slot No 1 Slot No 2 OUT I 01 I 01 IN Slot No 0 Not mountable Mountable Power suppl...

Страница 10: ...t points 8 channels cold junction temperature compensation channel module Isolation specifications Disconnection detection Not available 5 Maximum number of writes for Flash memory 50 000 Number of I...

Страница 11: ...accuracy is as follows 2 5 0 4 35 30 1 5 5 3 The conversion speed indicates the maximum time period from which the input temperature starts changing to which the temperature mesurement value of the bu...

Страница 12: ...9 5 1600 to 1760 3 3 3 K 270 to 200 3 3 3 200 to 0 2 Larger value of 0 5 and 0 5 of measured temperature Larger value of 0 06 and 0 2 of measured temperature 11 0 0 to 1200 2 Larger value of 0 25 and...

Страница 13: ...easily fixed onto the base unit using the hook at the top of the module When using the programmable controller in an environment of frequent vibrations however fix the module with a module fixing scr...

Страница 14: ...g timer error occurred or online module change enabled 2 ERR LED Displays the error status of the Q68TD G H01 On Error Flashing Error in switch settings Switch No 5 of the intelligent function module...

Страница 15: ...CH2 A4 B4 A5 CH3 B5 CH3 A6 B6 A7 CH4 B7 CH4 A8 B8 A9 CH5 B9 CH5 A10 B10 A11 CH6 B11 CH6 A12 B12 A13 CH7 B13 CH7 A14 B14 A15 CH8 B15 CH8 A16 B16 A17 B17 A18 B18 A19 B19 RTD A20 RTDG B20 RTD Seen from t...

Страница 16: ...igh frequency waves such as an inverter s load circuit Not doing so will cause the module more susceptible to noises surges and inductions 3 The following wiring is required for the product to comply...

Страница 17: ...the accuracy Moreover the Q68TD G H01 needs to be powered for 30 minutes warm up when the offset gain setting is performed and after the online module replacement is performed G CH1 CH8 G RTD A1 B1 A1...

Страница 18: ...ing a value other than 0 to 7 a thermocouple type settings error 10 indicates target channel number occurs and a temperature conversion is not performed Switch 2 Thermocouple type settings CH5 to CH8...

Страница 19: ...12 6 EXTERNAL DIMENSIONS Unit mm in 27 4 1 08 98 137 5 39 90 3 54 47 1 85...

Страница 20: ...e Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi E...

Отзывы: