8
Service Ref.
Item
Btu/h
W
kW
kW
A
A
kW
K
/min(CFM)
Pa(mmAq)
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kW
A
A
kW
W
kW
K
/min(CFM)
dB
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
L
mm(in.)
mm(in.)
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle, voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Lo / Mi1 / Mi2 / Hi)
External static pressure
Operation control & Thermostat
Noise level(Lo / Mi1 / Mi2 / Hi)
Unit drain pipe I.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Input
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
INDOOR UNIT
OUTDOOR UNIT
REFRIGERANT PIPING
PMH-P2BA
Cooling
18,300
5,350
2.31
0.06
0.29
0.32
2.44
71
NE38VMJM
w
1
Heating
21,200
6,200
2.37
0.06
0.29
0.32
2.53
29
NE38YEJM
w
2
W
D
H
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
PMH-P2BA
Single, 50Hz, 220 / 230 / 240V
Unit : Galvanized sheets with gray heat insulation, Grille munsell 0.98Y 8.99/0.63
Plate fin coil
Lineflow fan (direct) x 1
0.028
8.0 / 9.0 / 10.0 / 11.0(282 / 318 / 353 / 388)
0(direct blow)
Remote controller & built-in
36-38-40-42
26(1-1/32)
Munsell 5Y 8/1
Linear Expansion Valve
Hermetic
1.7
Line start
35
Plate fin coil
Propeller (direct) x 1
0.070
55(1,940)
Reverse cycle
48
49
900(35-7/16)
330+20(13+3/4)
855(33-5/8)
71(157)
R407C
3.1(6.8)
1.2(Ester)MEL56
9.52(3/8)
15.88(5/8)
Flared
Flared
Max. 40m
Max. 40m
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor
: D.B. 27˚C(80˚F), W.B. 19˚C (66˚F)
Outdoor : D.B. 35˚C(95˚F), W.B. 24˚C (75˚F)
Heating : Indoor
: D.B. 20˚C(68˚F)
Outdoor : D.B. 7˚C(45˚F), W.B. 6˚C (43˚F)
Refrigerant piping length (one way) : 5m (16ft)
2. Guaranteed operating range
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
D.B. 35˚C W.B. 22.5˚C
D.B. 19˚C W.B. 15˚C
D.B. 28˚C
D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C
D.B. 24˚C W.B. 18˚C
D.B. -11˚C W.B. -12˚C
Cooling
Heating
UNIT : 854(33-5/8) PANEL : 1000(39-3/8)
UNIT : 395(15-9/16) PANEL : 470(18-1/2)
UNIT : 230(9-1/16) PANEL : 30(1-3/16)
UNIT : 14(31) PANEL : 3.0(6.6)
PUH-P2VGA
PUH-P2YGA
PUH-P2VGA
PUH-P2YGA
Single, 50Hz,
220 / 230 / 240V
10.91
3-phase, 50Hz,
380 / 400 / 415V(4wires)
3.73
Single, 50Hz,
220 / 230 / 240V
11.21
3-phase, 50Hz,
380 / 400 / 415V(4wires)
3.73
w
1: Inner thermostat, HP switch, Discharge thermo.
w
2: Thermal relay, Discharge thermo, HP switch, Anti-phase protector.
3. Above data based on indicated voltage
Indoor Unit
1 phase 230V 50Hz
Outdoor Unit
1 phase 230V 50Hz
3 phase 400V 50Hz