8
Cooling
33,100
9,700
3.46
0.26
1.25
2.0
UNIT : 840(33-1/6)
UNIT : 840(33-1/6)
UNIT : 298(11-3/4)
UNIT : 30(66)[32(71)]
3.52 / 3.20
16.30 / 5.24
79 / 40
Heating
35,500[44,400]
10,400[13,000]
3.45[6.05]
0.26[2.86]
1.25[11.93]
2.0[12.7]
PANEL : 950(37-3/8)
PANEL : 950(37-3/8)
PANEL : 30(1-3/16)
PANEL : 5(11)
3.52 / 3.19
16.30 / 5.22
79 / 40
Service Ref.
Power supply(phase, cycle,voltage)
External finish
Heat exchanger
Fan
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
External finish
Refrigerant control
Compressor
Heat exchanger
Fan
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor units
Input
Running current
Starting current
Fan(drive) x No.
Fan motor output
Airflow(Low-High)
External static pressure
Input
Running current
Starting current
Model
Motor output
Starter type
Protection devices
Fan(drive) x No.
Fan motor output
Airflow
Charge
Oil<Model>
W
D
H
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Function
Capacity
Total input
INDOOR UNIT
OUTDOOR UNIT
REFRIGERANT
PIPING
Item
Service Ref.
Single, 50Hz, 220-240V
Grille : Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct) x 1
0.120
20-28(705-990)
0(direct blow)
[2.6]
Remote controller & built-in
33-41
32(1-1/4)
PUH-4VKSA.UK / PUH-4YKSA
2
.UK
Single 50Hz 220V-240V / 3, 50Hz, 380V-415V(4wire)
Munsell 5Y 7/1
Capillary tube
Hermetic
NH56VNDT / NH56YDAT
2.7
Line start
Internal thermostat, HP switch / Anti-phase protector, Thermal relay, Thermal switch, HP switch
Plate fin coil
Propeller (direct) x2
0.065+0.065
95(3550)
Reverse cycle
54
870(34-1/4)
295+24(11-5/8 add 1)
1258(49-1/2)
94(207)
R-22
4.2(9.2)
1.6<MS-32>
9.52(3/8)
19.05(3/4)
Flared
Flared
Max. 50m
Max. 50m
Btu/h
W
kW
kW
A
A
kW
K
/ min (CFM)
Pa
kW
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kW
A
A
kW
kW
K
/ min (CFM)
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
L
mm(in.)
mm(in.)
PLH-4AKS.UK PLH-4AKS
1
.UK
PLH-4AKHS.UK PLH-4AKHS
1
.UK
PLH-4AKS.UK PLH-4AKS
1
.UK
PLH-4AKHS.UK PLH-4AKHS
1
.UK
Notes:
Rating condition (ISO T1<JIS B8616>)
Cooling: Indoor
: D.B. 27°C, W.B. 19°C
Outdoor : D.B. 35°C, W.B. 24°C
Heating: Indoor
: D.B. 20°C
Outdoor : D.B. 7°C, W.B. 6°C
Refrigerant piping length(one way):5m(16ft)
Guaranteed operating range
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
Outdoor
Cooling
Heating
D.B. 35˚C, W.B. 22.5˚C
D.B. 21˚C, W.B. 15.5˚C
D.B. 27
°
C
D.B. 20
°
C
D.B. 46˚C
D.B. -5˚C
D.B. 21˚C, W.B. 15.5˚C
D.B. -8.5˚C, W.B. -9.5˚C
OC211-A--1.qxp 04.9.28 4:39 PM Page 8