Model

RP3

RP4

RP5

RP6

Capacity (Cooling/Heating) *1

<kW>

7.10/8.00

10.00/11.20

12.50/14.00

14.00/16.00

Total Input (Cooling/Heating) *1

<kW>

2.48/2.47

3.25/3.20

4.42/4.30

5.03/4.73

Power source (voltage <V>/Frequency <Hz>)

Height

<mm>

428

428

428

428

Dimension

Width

<mm>

785

1055

1055

1415

Depth

<mm>

690

690

690

690

Fan Airflow rate (Low-High)

<m

3

/min>

22-27

27-34

34-42

48-60

External static pressure

<Pa>

125

125

125

125

Noise level (Low-High)

<dB>

52-55

54-58

54-58

51-55

Net weight

<kg>

46

58

72

73

*1 Cooling: Indoor 27 °CDB/19 °CWB, Outdoor 35 °CDB

Heating: Indoor 20 °CDB, Outdoor 7 °CDB/6 °CWB

5. Specifications

PEA-RP

·

EA + PUHZ-RP

·

VHA

Model

RP3

RP4

RP5

RP6

Power source (voltage <V>/Frequency <Hz>)

V:~/N 220-230-240/50

Height

<mm>

943

1350

Dimension

Width

<mm>

950

Depth

<mm>

330+30

Fan Airflow rate

<m

3

/min>

55

100

Net weight

<kg>

75

121

PUHZ-RP

·

VHA

Содержание PEA-RP.EA

Страница 1: ...Air Conditioners PEA RP EA PUHZ RP HA OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit FOR USER FOR INSTALLER ...

Страница 2: ...part which must be grounded Indicates that caution should be taken with rotating parts Indicates that the main switch must be turned off before servicing Beware of electric shock Beware of hot surface ELV At servicing please shut down the power supply for both of Indoor Unit and Outdoor Unit Warning Carefully read the labels affixed to the main unit Warning The unit should not be installed by the ...

Страница 3: ...er is the wired type or the wireless type before referring to the illustration and text for operation procedures 2 1 Switching the unit on off The power supply should not be turned off while the air conditioner is in use This can cause the unit to break down 1 Press the ON OFF button A The ON indicator should light up Even if you press the ON OFF button immediately after shutting down the opera ti...

Страница 4: ... 28 C Circulation Not available The display flashes either 8 C 39 C to inform you if the room temperture is lower or higher than the displayed temperature TIMER SET ON OFF C C FILTER CHECK TEST TEMP A 1 ON OFF ON OFF TIMER SET ON OFF CLOCK C C FILTER CHECK TEST TEMP A 2 1 B TIMER SET ON OFF CLOCK ON OFF C C FILTER CHECK TEST TEMP 1 D B 2 3 C A 2 5 Using the timer 1 Set the current time 1 Press but...

Страница 5: ...direct sunlight or by using a heat source such as an electric heater this may warp them Do not wash the filters in hot water above 50 C as this may warp them Make sure that the air filters are always installed Operating the unit without air filters can cause malfunction 3 Care and cleaning A B Caution Before you start cleaning stop operation and turn OFF the power supply The air filter should be o...

Страница 6: ...OWER ON OFF button on the remote controller If none of the above apply turn the main switch off and contact the dealer from whom you bought the air conditioner telling him the model name and the nature of the problem Do not try to fix the unit yourself In any of the following cases turn off the main power switch and contact your local dealer for service The operation lamp on the main unit flashes ...

Страница 7: ... Fan Airflow rate Low High m3 min 22 27 27 34 34 42 48 60 External static pressure Pa 125 125 125 125 Noise level Low High dB 52 55 54 58 54 58 51 55 Net weight kg 46 58 72 73 1 Cooling Indoor 27 CDB 19 CWB Outdoor 35 CDB Heating Indoor 20 CDB Outdoor 7 CDB 6 CWB 5 Specifications PEA RP EA PUHZ RP VHA Model RP3 RP4 RP5 RP6 Power source voltage V Frequency Hz V N 220 230 240 50 Height mm 943 1350 D...

Страница 8: ...BG79S820H01 Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...

Отзывы: