background image

4

2

2.4. Selecting a fan speed 

1

Press 

  button to select a desired fan speed.

• Each time you press the button, available options change with the display 

A

 on

the remote controller, as shown below.

Fan speed

Remote controller display

Low

High

2-stage

The display and the fan speed of the unit will differ in the following situations:
• When STAND BY and DEFROST are displayed.
• Just after the heating mode (while waiting to change to another mode).
• When the temperature of the room is higher than the temperature setting of the

unit operating in the heating mode.

• In the dry operation, the indoor fan automatically turns to low-speed operation.

Switching of fan speed is impossible.

2. Operation

TIMER SET

ON/OFF 

˚C

˚C

FILTER

CHECK TEST

TEMP.

A

1

2.3. Selecting a temperature 

TEMP.

s

s

s

s

s

To decrease the room temperature:

1

Press 

 button to set the desired temperature.

A

The selected temperature is displayed.

• Each time you press the button, the temperature value decreases by 1 °C.

s

s

s

s

s

To increase the room temperature:

1

Press 

 button to set the desired temperature.

A

The selected temperature is displayed.

• Each time you press the button, the temperature value increases by 1 °C.

• Available temperature ranges are as follows:

Cooling & Drying:

19 - 30 °C

Heating:

17 - 28 °C

Automatic:

19 - 28 °C

Circulation:

— (Not available)

• The display flashes either 8 °C - 39 °C to inform you if the room temperture is lower

or higher than the displayed temperature.

TIMER SET

ON/OFF 

˚C

˚C

FILTER

CHECK TEST

TEMP.

A

1

ON

OFF

ON

OFF

TIMER SET

ON/OFF 

CLOCK

˚C

˚C

FILTER

CHECK TEST

TEMP.

A

2

1

B

TIMER SET

ON/OFF 

CLOCK

ON

OFF

˚C

˚C

FILTER

CHECK TEST

TEMP.

1

D

B

2

3

C

A

2.5. Using the timer

1)

Set the current time

1

Press 

 button to display the “CLOCK” 

B

.

Remote

CLOCK 

 

CLOCK

ON

 

 

CLOCK

OFF

 

→ 

No Display

controller display 

A

2

Each time you press 

 button, the time increases in increments of one minute.

Each time you press 

 button, the time decreases in increments of one minute.

• Press and hold the button to rapidly change the time.
• The time changes in increments of one minute 

→ 

ten minutes 

→ 

in units of hour; in

this order.

• Approximately ten seconds after pressing the button, the display on the remote

controller will turn off.

The example shows a timer set for operation start at 8:00 and end at 17:00.

2)

Set the mode to continuous as follows

1

Press 

 button to display 

 

D

.

3)

Set the time to start the unit as follows

2

Press 

 button to display 

B

 

ON

.

3

Press 

TIMER SET

 button to set the time that you want the unit to start.

The start time is displayed at 

A

.

4)

Set the time to stop the unit as follows

2

Press 

 button to display 

C

 

OFF

.

3

Press 

TIMER SET

 button to set the time that you want the unit to stop.

The stop time is displayed at 

A

.

5)

Set the mode to timer as follows

1

Press 

 button to display 

 D

.

Содержание PEA-RP.EA

Страница 1: ...Air Conditioners PEA RP EA PUHZ RP HA OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit FOR USER FOR INSTALLER ...

Страница 2: ...part which must be grounded Indicates that caution should be taken with rotating parts Indicates that the main switch must be turned off before servicing Beware of electric shock Beware of hot surface ELV At servicing please shut down the power supply for both of Indoor Unit and Outdoor Unit Warning Carefully read the labels affixed to the main unit Warning The unit should not be installed by the ...

Страница 3: ...er is the wired type or the wireless type before referring to the illustration and text for operation procedures 2 1 Switching the unit on off The power supply should not be turned off while the air conditioner is in use This can cause the unit to break down 1 Press the ON OFF button A The ON indicator should light up Even if you press the ON OFF button immediately after shutting down the opera ti...

Страница 4: ... 28 C Circulation Not available The display flashes either 8 C 39 C to inform you if the room temperture is lower or higher than the displayed temperature TIMER SET ON OFF C C FILTER CHECK TEST TEMP A 1 ON OFF ON OFF TIMER SET ON OFF CLOCK C C FILTER CHECK TEST TEMP A 2 1 B TIMER SET ON OFF CLOCK ON OFF C C FILTER CHECK TEST TEMP 1 D B 2 3 C A 2 5 Using the timer 1 Set the current time 1 Press but...

Страница 5: ...direct sunlight or by using a heat source such as an electric heater this may warp them Do not wash the filters in hot water above 50 C as this may warp them Make sure that the air filters are always installed Operating the unit without air filters can cause malfunction 3 Care and cleaning A B Caution Before you start cleaning stop operation and turn OFF the power supply The air filter should be o...

Страница 6: ...OWER ON OFF button on the remote controller If none of the above apply turn the main switch off and contact the dealer from whom you bought the air conditioner telling him the model name and the nature of the problem Do not try to fix the unit yourself In any of the following cases turn off the main power switch and contact your local dealer for service The operation lamp on the main unit flashes ...

Страница 7: ... Fan Airflow rate Low High m3 min 22 27 27 34 34 42 48 60 External static pressure Pa 125 125 125 125 Noise level Low High dB 52 55 54 58 54 58 51 55 Net weight kg 46 58 72 73 1 Cooling Indoor 27 CDB 19 CWB Outdoor 35 CDB Heating Indoor 20 CDB Outdoor 7 CDB 6 CWB 5 Specifications PEA RP EA PUHZ RP VHA Model RP3 RP4 RP5 RP6 Power source voltage V Frequency Hz V N 220 230 240 50 Height mm 943 1350 D...

Страница 8: ...BG79S820H01 Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...