35
OFF
2-time flash
3-time flash
4-time flash
5-time flash
6-time flash
7-time flash
8-time flash
Lighting Lighting
Lighting
Once
Lighting
Once
Lighting Twice
Lighting 3 times
Lighting 4 times
Lighting 9 times
Once
Goes
out
Lighting Lighting
Lighting Lighting
3 times
Goes
out
4 times
Goes
out
Lighting Lighting
Lighting Lighting
Lighting 5 times
9-time flash
10-time flash
• Check the connection
of the compressor
connecting wire.
• Refer to 10-5.
A
"How to check
inverter / compressor".
• Check the stop valve.
• Replace the outdoor
electronic control
P.C. board.
•Check refrigerant circuit
and refrigerant amount.
• Refer to 10-5.
L
"Check
of LEV".
• Refer to 10-5.
I
"Check
of outdoor fan motor".
• Replace the outdoor
electronic control
P.C. board.
•Check refrigerant circuit
and refrigerant amount.
• Refer to 10-5.
L
"Check
of LEV".
• Reconnect compressor
connector.
• Refer to 10-5.
A
"How to
check inverter/
compressor."
• Check the stop valve.
•Check refrigerant circuit
and refrigerant amount.
• Check the stop valve.
• Check around outdoor
unit.
• Check outdoor unit air
passage.
• Refer to 10-5.
I
"Check
of outdoor fan motor".
• Refer to 10-5.
G
"Check
of outdoor thermistors".
• Refer to 10-5.
G
"Check
of outdoor thermistors".
When IPM protection stop or lock
protection stop is continuously
performed three times within 1
minute after the compressor gets
started, or when converter
protection stop or bus-bar voltage
protection stop is continuously
performed three times within 3
minutes after start-up.
When thermistor shorts or opens
during compressor running.
When 28A current flow into intelligent
power module.
When the outdoor heat exchanger
temperature exceeds 158
°
F (70
:
)
during cooling or the indoor gas
pipe temperature exceeds 158
°
F (70
:
)
during heating (MUZ).
When the fin temperature exceeds
189
°
F (87
:
) during operation.
When the P.C. board temperature
exceeds 158
°
F (70
:
) during operation.
When failure occurs continuously
three times within 30 seconds after
the fan gets started.
When nonvolatile memory data
cannot be read properly.
When the frequency of the
compressor is kept 80Hz or
more and the discharge
temperature is kept under 102
°
F (39
:
)
for more than 20
minutes.
Outdoor power system
Non (Normal)
Discharge temperature
thermistor
Defrost thermistor (MUZ)
Ambient temperature thermistor
Fin temperature thermistor
P.C. board temperature
thermistor
Outdoor heat exchanger
temperature thermistor
Over current
Discharge temperature
High pressure
Fin temperature
P.C. board temperature
Outdoor fan motor
Nonvolatile memory data
Discharge temperature
-
-
Abnormal point
(Failure mode / protection)
Condition
Correspondence
Indoor/outdoor
unit failure mode
recall function
LED indication
(Outdoor P.C. board)
LED 1
LED 2
When temperature of discharge
temperature thermistor exceeds 241
°
F
(116
:
)
, compressor stops.
Compressor can restart if discharge
temperature thermistor reads
212
°
F
(100
:
)
or less 3 minutes later.
The left lamp of
OPERATION INDICATOR
lamp(Indoor unit)
NOTE : Blinking patterns of this mode differ from the ones of Troubleshooting check table (10-3.).
MUZ-A24NA MUY-A24NA
OB451--2.qxp 06.3.29 9:49 AM Page 35
Содержание MUY-A15NA
Страница 11: ...11 WIRING DIAGRAM 5 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA...
Страница 12: ...12 MUY A15NA MUY A17NA...
Страница 13: ...13 MUZ A24NA...
Страница 14: ...14 MUY A24NA...
Страница 68: ...68 2 OUTDOOR UNIT ELECTRICAL PARTS 8 1 4 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA MUY A15NA MUY A17NA 2 3 5 6 7...
Страница 74: ...74 2 OUTDOOR UNIT ELECTRICAL PARTS 8 1 4 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA MUY A15NA MUY A17NA 2 3 5 6 7...