background image

En-9

● OPERATING INSTRUCTIONS ●

Even if these items are checked, when the unit does not recover from the 

trouble, stop using the air conditioner and consult your dealer.

Symptom

Explanation & Check points

Indoor Unit

The unit cannot be operated.

•  Is the breaker turned on?

•  Is the power supply plug connected?

•  Is the ON timer set? 

 Page 7 

The horizontal vane does not 

move.

•  Are the horizontal vanes installed correctly?

•  Is the fan guard deformed?

The unit cannot be operated 

for about 3 minutes when 

restarted.

•  This protects the unit according to instruc-

tions from the microprocessor. Please wait.

Mist is discharged from the air 

outlet of the indoor unit.

•  The cool air from the unit rapidly cools mois-

ture in the air inside the room, and it turns 

into mist.

The swing operation of the 

HORIZONTAL VANE is 

suspended for a while, then 

restarted.

•  This is for the swing operation of the HORI-

ZONTAL VANE to be performed normally.

The airfl ow direction changes 

during operation.

The direction of the horizontal 

vane cannot be adjusted with 

the remote controller.

•  When the unit is operated in COOL or DRY 

mode,  if  the  operation  continues  with  air 

blowing down for 0.5 to 1 hour, the direction 

of the airfl ow is automatically set to upward 

position to prevent water from condensing 

and dripping.

•  In the heating operation, if the airfl ow tem-

perature is too low or when defrosting is be-

ing done, the horizontal vane is automatically 

set to horizontal position.

The operation stops for about 

10 minutes in the heating 

operation.

•  Outdoor unit is in defrost.

  Since this is completed in max.10 minutes, 

please wait. (When the outside temperature 

is too low and humidity is too high, frost is 

formed.)

The unit starts operation by 

itself when the main power is 

turned on, but hasn’t received 

sign from the remote control-

ler.

•  These models are equipped with an auto re-

start function. When the main power is turned 

off without stopping the unit with the remote 

controller and is turned on again, the unit 

starts operation automatically in the same 

mode as the one set with the remote control-

ler just before the shutoff of the main power. 

Refer to “Auto restart function” 

 page 5 

.

The indoor unit discolors over 

time.

•  Although plastic turns yellow due to the infl u-

ence of some factors such as ultraviolet light 

and temperature, this has no effect on the 

product functions.

Multi system

The indoor unit which is not 

operating becomes warm and 

a sound, similar to water fl ow-

ing, is heard from the unit.

•  A small amount of refrigerant continues to 

fl ow into the indoor unit even though it is not 

operating.

When heating operation is 

selected, operation does not 

start right away.

•  When operation is started during defrosting 

of outdoor unit is done, it takes a few minutes 

(max. 10 minutes) to blow out warm air.

Outdoor Unit

The fan of the outdoor unit 

does not rotate even though 

the compressor is running. 

Even if the fan starts to rotate, 

it stops soon.

•  When the outside temperature is low during 

cooling operation, the fan operates intermit-

tently to maintain suffi cient cooling capacity.

Water leaks from the outdoor 

unit.

•  During COOL and DRY operations, pipe or 

pipe connecting sections are cooled and this 

causes water to condense.

•  In the heating operation, water condensed 

on the heat exchanger drips down.

•  In  the  heating  operation,  the  defrosting 

operation makes ice forming on the outdoor 

unit melt and drip down.

White smoke is discharged 

from the outdoor unit.

•  In  the  heating  operation,  vapor  generated 

by the defrosting operation looks like white 

smoke.

Symptom

Explanation & Check points

Remote controller

The display on the remote 

controller does not appear 

or it is dim. The indoor unit 

does not respond to the 

remote control signal.

•  Are the batteries exhausted? 

 Page 4 

•  Is the polarity (+, -) of the batteries correct?

 Page 4 

•  Are any buttons on the remote controller of 

other electric appliances being pressed?

Does not cool or heat

The room cannot be cooled 

or heated suffi ciently.

•  Is  the  temperature  setting  appropriate? 

 Page 5 

•  Is the fan setting appropriate? Please change 

fan speed to High or Super High. 

 Page 6 

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean?

•  Are there any obstacles blocking the air inlet 

or outlet of the indoor or outdoor unit?

•  Is a window or door open?

•  It may take a certain time to reach the setting 

temperature or may not reach that depending 

on the size of the room, the ambient tempera-

ture, and the like.

The room cannot be cooled 

suffi ciently.

•  When  a  ventilation  fan  or  a  gas  cooker  is 

used in a room, the cooling load increases, 

resulting in an insuffi cient cooling effect.

•  When  the  outside  temperature  is  high,  the 

cooling effect may not be suffi cient.

The room cannot be heated 

suffi ciently.

•  When  the  outside  temperature  is  low,  the 

heating effect may not be suffi cient.

Air does not blow out soon in 

the heating operation.

•  Please wait as the unit is preparing to blow 

out warm air.

Airfl ow

The air from the indoor unit 

smells strange.

•  Are the fi lters clean? 

 Page 8 

•  Is the fan or heat exchanger of the indoor unit 

clean?

•  The unit may suck in an odor adhering to the 

wall, carpet, furniture, cloth, etc. and blow it 

out with the air.

Sound

Cracking sound is heard.

•  This sound is generated by the expansion/

contraction  of  the  front  panel,  etc.  due  to 

change in temperature.

“Burbling” sound is heard.

•  This sound is heard when the outside air is 

absorbed from the drain hose by turning on 

the range hood or the ventilation fan, making 

water fl owing in the drain hose to spout out.

  This sound is also heard when the outside air 

blows into the drain hose in case the outside 

wind is strong.

Mechanical sound is heard 

from the indoor unit.

•  This is the switching sound in turning on/off 

the fan or the compressor.

The sound of water fl owing 

is heard.

•  This is the sound of refrigerant or condensed 

water fl owing in the unit.

Hissing sound is sometimes 

heard.

•  This is the sound when the fl ow of refrigerant 

inside the unit is changed.

In the following cases, stop using the air conditioner and consult your 

dealer.

•  When water leaks or drips from the indoor unit.

•  When the upper operation indicator lamp blinks.

•  When the breaker trips frequently.

•  The remote control signal is not received in a room where an electronic ON/OFF 

type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.

•  Operation of the air conditioner interferes with radio or TV reception. An ampli-

fi er may be required for the affected device.

•  When an abnormal sound is heard.

•  When any refrigerant leakage is found.

W

HEN YOU THINK THAT TROUBLE HAS OCCURRED

JG79Y022H01_en.indd   9

7/30/2015   7:57:07 PM

Содержание MSZ-GL06NA

Страница 1: ... forma correcta y segura lea previamente estas instrucciones de funcionamiento NOTICE D UTILISATION A l attention des clients Pour avoir la certitude d utiliser cet appareil correctement et en toute sécurité veuillez lire cette notice d instructions avant de mettre le clima tiseur sous tension SPLIT TYPE AIR CONDITIONERS INDOOR UNIT MSZ GL06NA MSZ GL09NA MSZ GL12NA MSZ GL15NA JG79Y022H01_cover ind...

Страница 2: ...ntal to your health The unit should not be installed relocated disassembled altered or repaired by the user An improperly handled air conditioner may cause fire electric shock injury or water leakage etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit make...

Страница 3: ... in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes Afte...

Страница 4: ...isplay section OFF ON stop operate button Temperature buttons Page 5 Operation select button Page 5 ECONO COOL button Page 7 FAN speed control button Page 6 Off timer button Page 7 On timer button Page 7 VANE control button Page 6 TIME set buttons Pages 4 7 Increase time Decrease time CLOCK button Page 4 RESET button Page 4 Lid Slide down to open Install the remote control ler holder in a place wh...

Страница 5: ... controller may not operate correctly Before operation Insert the power supply plug into the power outlet and or turn the breaker on Installing the remote controller batteries PREPARATION BEFORE OPERATION Press CLOCK gently using a thin instrument Setting current time Changing temperature units F C Unit is preset with F 1 Press RESET while the temperature but tons are pressed Press RESET gently us...

Страница 6: ... temperature by 1 F 1 C Press to stop the operation The same setting is selected the next time by simply pressing Auto restart function If a power failure occurs or the main power is turned off during operation Auto restart function automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power When timer is set timer setting is ...

Страница 7: ...To change the horizontal airflow direction Move the vertical vane manually before starting operation 1 Press during COOL ECONO COOL or HEAT mode to select SMART SET mode 2 Set the temperature fan speed and airflow direction The same setting is selected from the next time by simply pressing Two settings can be saved One for COOL ECONO COOL one for HEAT Select the appropriate temperature fan speed and...

Страница 8: ...F 2 C higher it is possible to perform cooling operation with keeping comfort As a result energy can be saved 1 Press or during operation to set the timer ON timer The unit turns ON at the set time OFF timer The unit turns OFF at the set time or blinks Make sure that the current time is set correctly Page 4 2 Press Increase and Decrease to set the time of timer Each press increases or decreases th...

Страница 9: ...g it After washing dry it well in shade Every year Replace it with a new air cleaning filter for best performance Parts Number MAC 408FT E Pull to remove from the air filter Important Clean the filters regularly for best performance and to reduce power consumption Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold It is therefore recommend...

Страница 10: ...r to condense In the heating operation water condensed on the heat exchanger drips down In the heating operation the defrosting operation makes ice forming on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Symptom Explanation Check points Remote controller The display on...

Страница 11: ...should be at least 10 ft 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature in manual COOL mode and operate for 3 to 4 hours Page 5 This dries the inside of the unit Moist...

Страница 12: ...iempo prolongado Puede ser perjudicial para la salud El usuario no debe instalar cambiar de sitio desmontar alterar ni reparar la unidad Si no se maneja correctamente el acondicionador de aire puede causar fuego descarga eléctrica lesiones escape de agua etc Consulte con su distribuidor Si el cable de alimentación está dañado deberá ser susti tuido por el fabricante o su agente de mantenimiento pa...

Страница 13: ...uido de la pila entra en contacto con los ojos lávelos a fondo con agua limpia y acuda a un médico de inmediato Asegúrese de que la zona está bien ventilada cuando la unidad esté en funcionamiento junto con un aparato de combustión Una ventilación inadecuada puede originar falta de oxígeno Coloque el disyuntor en OFF si oye truenos y hay posibilidad de que caigan rayos La unidad puede resultar dañ...

Страница 14: ...ador de calor Soporte del controla dor remoto Instale el soporte del con trolador remoto en un lugar en el que la unidad interior pueda recibir la señal Sección de transmi sión de señales Distancia de la señal Aprox 20 ft 6 m Cuando se recibe la señal la unidad interior emite un sonido Sección de pantalla de accionamiento Botón OFF ON desactivación activación de funcionamiento Botón de control de ...

Страница 15: ... la puesta en marcha inserte el enchufe de alimentación en la toma de corriente y o encienda el disyuntor Instalación de las pilas del controlador remoto PREPARACIÓN ANTES DE LA PUESTA EN MARCHA Pulse CLOCK temporizador suavemente utilizando un objeto en punta Ajuste de la hora actual Cambio de unidades de temperatura F C La unidad esta configurada por defecto con F 1 Pulse RESET reini ciar con los...

Страница 16: ...mperatura Cada pulsación eleva o disminuye la temperatura en 1 F 1 C Pulse para apagarlo Cuando vuelva a encenderlo se activará la misma configuración se leccionada si pulsa Función de reinicio automático En caso de que se produzca un corte en el suministro eléctrico o se apague la unidad mientras esté funcionando la Función de reinicio automático se activará automáticamente en el mismo modo selec...

Страница 17: ...desplaza hacia arriba y hacia abajo de forma intermitente Para cambiar la dirección del flujo de aire Desplace el deflector vertical manual antes de que empiece a funcionar el acondicionador 1 Pulse durante el modo de REFRIGERACIÓN DESCONEXIÓN AUTOMÁTICA ECONO COOL o CALEFACCIÓN para seleccionar el modo SMART SET SELECCIÓN INTELIGENTE 2 Establezca la temperatura la velocidad del ventilador y la dire...

Страница 18: ...emporizador en ACTIVACIÓN DESACTIVACIÓN consulte la Página 5 Función de reinicio automático FUNCIONAMIENTO DE LA DESCONEXIÓN AUTOMÁTICA ECONO COOL Pulse durante el modo de REFRIGERACIÓN Página 5 para iniciar el funcionamiento de desco nexión automática ECONO COOL La unidad realiza la operación de oscilación verticalmente en varios ciclos según la temperatura del flujo de aire La temperatura fijada...

Страница 19: ...os Tras el lavado séquelo bien a la sombra Cada año Cambie el filtro de aire por uno nuevo para un mejor rendimiento Número de las piezas MAC 408FT E Tire para desacoplar del filtro de aire Importante Limpie los filtros con regularidad para un mejor rendi miento y para reducir el consumo de electricidad Los filtros sucios pueden provocar condensación en el acondicionador de aire que contribuye a la fo...

Страница 20: ...s conexiones de los tubos hace que se condense el agua En el modo de calefacción el agua se conden sa en el intercambiador de calor y empieza a gotear En el modo de calefacción la función de des escarchado derrite el hielo adherido a la unidad exterior y el agua empieza a gotear Síntoma Explicación y puntos de comprobación Unidad exterior Sale humo blanco de la unidad exterior En el modo de calefa...

Страница 21: ...da en el aparato de aire acondicionado pue de contribuir a la formación y expansión de hongos como el moho 2 Pulse para que se detenga 3 Desconecte el disyuntor o desconecte el enchufe de la alimentación 4 Quite todas las pilas del controlador remoto Al volver a usar el acondicionador de aire 1 Limpie el filtro del aire Página 8 2 Compruebe que no estén bloqueadas las entradas y salidas de aire de ...

Отзывы: