251
BKBIN, BKBINP
1
2
3
4
6
7
8
6.3
D
ata conversio
n instru
ctions
6.3.15
BKB
IN
, BKB
IN
P
Operation Error
(1) In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into
SD0.
Program Example
(1) The following program converts, when X20 is turned ON, the BIN data stored at D100 to D102 to BCD and stores the
operation result into the area starting from D200.
[Ladder Mode]
[List Mode]
[Operation]
: Head number of the devices where BCD data is stored (BCD 4 digits)
: Head number of the devices where the converted BIN data will be stored (BIN 16 bits)
n
: Number of variable data blocks (BIN 16 bits)
Error
code
Error details
Q00J/
Q00/
Q01
QnH
QnPH QnPRH
QnU
LCPU
4100
The nth data from the device specified by is outside the 0 to 9999
range.
4101
The points specified in n exceed those of the corresponding device
specified in or .
The same device is specified in and .
BKBIN, BKBINP
Conversion from block BCD 4-digit data to block BIN 16-bit
data
6.3.15
BKBIN, BKBINP
Setting
Data
Internal Devices
R, ZR
J \
U \G
Zn
Constants
K, H
Other
Bit
Word
Bit
Word
––
––
––
––
––
––
n
––
S
S
D
S
D
Step
Instruction
Device
BCD
conversion
0 1 0 1 0 1 0 0 0 0 1 1 0 0 1 0
0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0
0 0 1 1 0 0 1 0 0 0 0 1 0 0 0 0
0 0 0 1 0 1 0 1 0 0 1 1 1 0 0 0
0 0 0 1 0 0 0 1 0 1 0 1 1 1 0 0
0 0 0 0 1 1 0 0 1 0 0 0 1 0 1 0
3
D0
D200 BCD 5432
D202 BCD 3210
D201 BCD 4444
D100 BIN 5432
D102 BIN 3210
D101 BIN 4444
8192 4096 2048 1024 512 256 128 64 32 16 8 4 2 1
2000 1000 800 400 200 100 80 40 20 10 8 4 2 1
4000
8000
Basic
Process
High
performance
Redundant Universal
LCPU
Command
Command
BKBINP
BKBIN
n
n
S
D
S
D
BKBINP
BKBIN
S
D
S
D