INTRODUCTION
This manual outlines the maintenance procedures for using the
AC servo system.
It details the methods involved in
replacing the transistor amplifiers as well as the inspection
locations and adjustments,
and it should thus be read before
operating the AC servo system.
Refer to the checkpoints before
switching on the power.
(1) SPECIFICATIONS
Item
TRS75
TRS150
Motor used
HA100
HA200
HA300
Continuous output
45Arms
66Arms
current
Output torque (when
458
709
1036
used in combination
kg.cm
kg.cm
kg.cm
kg.cm
with amplifier)
Rated output voltage
Alarm circuits
Fin overheating protection (FOH), power
unit alarm (PUAL), motor overloading
(MOH),
TG over-speeding (TGOV),
current detection (OVC), instant
current protection (OCP), no-signal de-
tection
instant power failure
compensation and under-voltage
compensation (LVAL).
Power supply
310V (DC) across P-N
(With AC 220V factory power supply)
Control loop
Current loop (sine wave approximation,
loop
Control characteristics
Speed control band:
500 rad/sec.
Speed control range: