– 5 –
6
Initial setting
* Turn on the power supply unit (PAC-SC50KUA) power and run and initially
set this unit.When the power is first turned on, the startup screen shown at
the right is displayed.
(When changing the initially set contents after various initial settings were
performed and the system was already started, the initial setting menu
screen is displayed by pressing the
↑
and
↓
switches simultaneously for
2 seconds or longer during user operation menu screen display.)
At the end of various initial settings, return to the user operation menu
screen by pressing the
↑
and
↓
switches simultaneously for 2 seconds
or longer.
Refer to the attached instruction book section 5.Initial setting for further
information.
1. Address setting method
1
When the startup screen is displayed at power on, press the
1
switch to select “1 ADDRESS SETTING”.
2
Press the
0
~
9
switches, and set the address of this unit. (000,201~250)
3
When the
BACK
SCREEN
←
switch is pressed after setting, the screen returns.
* Always set to [000] when using K transmission converter.
* The M-NET address initial value of this unit is [000].
2. Function selection method
1
On the startup screen, press the
2
switch to select “2 FUNCTION SETTING”.
2
Switch the function by pressing the
1
~
8
switch of the same No. as the function No. you want to change.
Each time the switch is pressed, the ON/OFF state of that No. is changed.
No.1 and No.2 cannot be changed.
When Function No. 3 is set to ON, set the K transmission converter address.
Move the address and Function setting using the
↑
,
↓
,
→
, and
←
keys.
<Operation example>
1) When the
3
switch was pressed
3
When the
BACK
SCREEN
←
switch is pressed, the screen is returned.
<Function Selection Display>
OFF : Not used (Fixed to off)
OFF : Not used (Fixed to off)
OFF : K transmission converter not provided/ON:K trahsmission converter provided
OFF : Operation prohibit transmission valid/ON:Operation prohibit transmission invalid
OFF : Emergency stop broadcast enabled/ON: Emergency stop broadcast disabled
External input changeover
The range of a controller which the operation is prohibited.
OFF : Both of the systems controller and the local remote controller/ON:Only the local remote controller
(NOTE)
The cover fixing screw is
packaged with the other enclosed
screws.
Insert a flat-tip screwdriver and
rotate it to remove the cover.
Electric box
Installation plate
Central controller
M4 countersunk
screw
M4 round head screw
1 ADDRESS SETTING
2 FUNCTION SETTING
3 IPADDRESS SETTING
4 GROUP SETTING
PLEASE SET
INITIAL SETTING
No. 1
No. 2
No. 3
No. 4
No. 5
No. 6
No. 7
No. 8
····
····
·
······
·
········
·
·········
·
·········
·
······
·
····
·
····
· ···
····
·
······
·
········
·
·········
·
·········
·
······
·
····
·
····
3
3
ON
OFF
ON
OFF
(OFF)
(ON)
5
Remove the controller’s cover and install on to the electric
box.
<Installation on to electric box>
NOTE
* When installing the controller directly on to a wall
instead of using the electric box, do not use the in-
stallation plate.
* If the screw enclosed for the installation plate, fixing
cannot be used because of the wall thickness, pre-
pare an M4 countersunk screw that matches the
wall thickness.
* When using an LAN and external signal I/O, refer to
section 9 External input/output usage method .
Содержание G-50A
Страница 2: ......