background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for 

accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE  : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Safety Precautions

 

(Read these precautions before use.)

This manual classify the safety precautions into two categories: 

 and 

.

Depending on the circumstances, procedures indicated by 

 may also

cause severe injury.
It is important to follow all precautions for personal safety.

Associated Manuals

How to obtain manuals

For the necessary product manuals or documents, consult with the Mitsubishi
Electric dealer from where you purchase your product.

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3S

 Series User’s Manual

- Hardware Edition

JY997D48601

MODEL CODE: 

09R535

Explains FX

3S

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3G

 Series User’s Manual

- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

Explains FX

3G

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series 

Programming Manual 
- Basic & Applied Instruction 
Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming

for basic/applied instructions

and devices.

Applicable standards

FX

3G

-4EX-BD 

units made in September, 2013 or later comply with the EC Directive

(EMC Directive). Further information can be found in the following manual.

→ 

FX

3S 

Series User's Manual - Hardware Edition

→ 

FX

3G 

Series User's Manual - Hardware Edition

Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Attention

This product is designed for use in industrial applications.

1. Outline

The 

FX

3G

-4EX-BD

 input expansion board (hereinafter referred to as "

4EX-BD

") is an

expansion board to be installed in the 

FX

3S

 or 

FX

3G

 series programmable controller

(hereinafter referred to as "PLC"), to add four additional inputs.

1.1 Incorporated Items

Verify that the following product and items are included in the package:

1.2 External Dimensions and Part Names 

[1] Terminal block mounting screws
[2] Input LED

 BX0 LED: The LED is lit when BX0 is on.
 BX1 LED: The LED is lit when BX1 is on.
 BX2 LED: The LED is lit when BX2 is on.
 BX3 LED: The LED is lit when BX3 is on.

[3] Mounting holes (2-

φ

3.2)

[4] Connector cover
[5] Main unit connector
[6] Terminal block for input (European)
[7] Memory cassette/Display module connector

Product

FX

3G

-4EX-BD

 input expansion board

Accessories

M3

×

8 tapping screws for installation: 2 pcs.

Side cover

USER’S MANUAL (This manual)

S/S

BX0

BX1

BX2

BX3

14.1

15.1

Unit: mm (inches)

35 (1.38")

51.2 (2.02")

[4]

[3]

[5]

[7]

Connector cover is 
removed

MASS (Weight): 
           Approx. 20 g (0.05 lbs)

[6]

[1]

(0.6") (0.56")

[2]

5 poles

Terminal Layout

BX1

LEDs correspond to each input terminal 

BX3

BX2

BX0

2. Installation

  

For installation/uninstallation details, refer to the following manual.

→ 

FX

3S 

Series User's Manual - Hardware Edition

→ 

FX

3G 

Series User's Manual - Hardware Edition

3. Wiring 

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in PLC
main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl

2

, H

2

S, SO

2

 or NO

2

), flammable gas, vibration 

or impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.

Make sure to affix the expansion board with tapping screws.
Tightening torque should follow the specifications in the manual.
Loose connections may cause malfunctions.

Use screwdrivers carefully when performing installation work, thus avoiding
accident or product damage.

When drilling screw holes or wiring, make sure that cutting and wiring debris do
not enter the ventilation slits of the PLC. 
Failure to do so may cause fire, equipment failures or malfunctions.

Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.

Connect expansion board securely to their designated connectors.
Loose connections may cause malfunctions.

DESIGN 
PRECAUTIONS

Make sure to have the following safety circuits outside of the PLC to ensure safe
system operation even during external power supply problems or PLC failure.
Otherwise, malfunctions may cause serious accidents.
1) Most importantly, have the following: an emergency stop circuit, a protection

circuit, an interlock circuit for opposite movements (such as normal vs.
reverse rotation), and an interlock circuit (to prevent damage to the equipment
at the upper and lower positioning limits).

2) Note that when the PLC CPU detects an error, such as a watchdog timer

error, during self-diagnosis, all outputs are turned off. Also, when an error that
cannot be detected by the PLC CPU occurs in an input/output control block,
output control may be disabled.
External circuits and mechanisms should be designed to ensure safe
machinery operation in such a case.

3) If an overload of the 24 V DC service power supply occurs, the voltage

automatically drops, inputs in the PLC are disabled, and all outputs are turned
off.
External circuits and mechanisms should be designed to ensure safe
machinery operation in such a case.

DESIGN 
PRECAUTIONS

Do not bundle the control line together with or lay it close to the main circuit or
power line. As a guideline, lay the control line at least 100 mm (3.94") or more
away from the main circuit or power line.
Noise may cause malfunctions.

WIRING 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

WIRING 
PRECAUTIONS

Connect the DC power supply to the dedicated terminals specified in the manual
of the PLC main unit.
If an AC power supply is connected to a DC input/output terminal or DC power
supply terminal, the PLC will burn out.

3.1 Applicable Cable and Terminal Tightening Torque

3.1.1

Terminal block (European type)

1) Wire size

Wiring to input device should use 22 to 20 AWG wire.

2) Applicable cable

3) Termination of cable end

Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
An alternative connection is to use a ferrule with insulating sleeve.
<Reference>

*1 Old model name: CRIMPFOX ZA 3
*2 Old model name: CRIMPFOX UD 6

When using a ferrule with insulation sleeve, choose a wire with proper cable
sheath referring to the above outside dimensions, or otherwise, the wire
cannot be inserted easily.
The tightening torque must be 0.22 to 0.25 N

m. Do not tighten terminal

screws exceeding the specified torque. Failure to do so may cause equipment
failures or malfunctions.

4) Tool

For tightening the terminal, use a 
commercially available small 
screwdriver having a straight form that is 
not widened toward the end as shown 
right.

Caution:

If the diameter of screwdriver grip is too 
small, tightening torque will not be able 
to be achieved. Use the following recommended screwdriver or an
appropriate replacement (grip diameter: approximately 25 mm (0.98")).
 <Reference>

WIRING 
PRECAUTIONS

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits. 
Failure to do so may cause fire, equipment failures or malfunctions.

Make sure to observe the following precautions in order to prevent
malfunctions under the influence of noise:

- Do not bundle the power line or input line together with or lay it close to the 

main circuit, high-voltage line or load line. 
Otherwise, noise disturbance and/or surge induction are likely to take 
place. 
As a guideline, lay the control line at least 100mm (3.94") or more away 
from the main circuit or high-voltage lines.

Make sure to properly wire to the terminal block (European type) in
accordance with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.

- The disposal size of the cable end should follow the dimensions described 

in the manual.

- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires 

of unspecified size.

- Affix the electric wires so that neither the terminal block nor the connected 

parts are directly stressed.

Type

Wire size

Single-wire

0.3 to 0.5 mm

2

 (AWG22 to 20)

2-wire

2 pieces of 0.3 mm

2

 (AWG22)

Manufacturer

Model

Caulking tool

Phoenix Contact Co., Ltd.

AI 0.5-8WH

CRIMPFOX 6

*1

(or CRIMPFOX 6T-F

*2

)

Manufacturer

Model

Phoenix Contact Co., Ltd.

SZS 0.4

×

2.5

9mm

(0.35")

- Strand wire/single wire

8mm

(0.31")

Contact area
(Crimp area)

14mm(0.55")

2.6mm(0.1")

Insulation sleeve

- Ferrule with insulation sleeve

With
straight tip

2.5mm

(0.1")

0.4mm
(0.02")

3.2 Wiring of input

→ 

For the terminal configuration, refer to Section 1.2

Sink input wiring

Source input wiring

*1 The service power supply of the PLC main unit can be used.

3.3 Grounding

Grounding should be performed as stated below.

The grounding resistance should be 100 

Ω

 or less.

Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared grounding" of
the following figure.
For details, refer to the following manual.

→ 

FX

3S

 Series User's Manual - Hardware Edition

→ 

FX

3G

 Series User's Manual - Hardware Edition

The grounding wire size should be AWG 22 to 20 (0.3 to 0.5 mm

2

).

The grounding point should be close to the PLC, and all grounding wire should
be as short as possible.

3.4 Instructions for connecting input devices

The input current of this PLC is 5 mA/24 V DC. Use input devices applicable to
this minute current.
If no-voltage contacts (switches) for large current are used, contact failure may occur.
<Example> Products of OMRON

3.4.1

In the case of input device with built-in series diode

The voltage drop of the series diode should be approx. 4 V or less.
When lead switches with a series LED are used, up to two switches can be
connected in series. Also make sure that the input current is over the input-
sensing level while the switches are ON.

Sink input wiring                             Source input wiring

*1 BX

 represents the input number of 4EX-BD.

Type

Model name

Type

Model name

Microswitch

Models Z, V 
and D2RV

Operations switch

Model A3P

Proximity switch

Model TL

Photoelectric
switch

Model E3S

S/S

24 V DC

*1

4EX-BD

4.3 k

Ω

BX0

BX1

BX3

BX2

4.3 k

Ω

4.3 k

Ω

4.3 k

Ω

S/S

4EX-BD

4.3 k

Ω

BX0

BX1

BX3

BX2

4.3 k

Ω

4.3 k

Ω

4.3 k

Ω

24 V DC

*1

PLC

PLC

PLC

Other

equipment

Shared grounding

Good condition

Common grounding

Not allowed

Independent grounding

Best condition

Other

equipment

Other

equipment

BX

*1

S/S

4EX-BD

BX

*1

S/S

4EX-BD

3.4.2

In the case of input device with built-in parallel resistance 

Use a device having a parallel resistance, Rp, of 15 k

Ω 

or more.

If the resistance is less than 15 k

Ω

, connect a bleeder resistance, Rb (k

Ω

), obtained by

the following formula as shown in the following figure.

Sink input wiring

                                 

 Source input wiring

*1 BX

 represents the input number of 4EX-BD.

3.4.3

In the case of 2-wire proximity switch

Use a two-wire proximity switch whose leakage current,

, is 1.5 mA or less when the

switch is off. When the current is larger than 1.5 mA, connect a bleeder resistance, Rb
(k

Ω

), determined by the following formula.

Sink input wiring

                                  

Source input wiring

*1 BX

 represents the input number of 4EX-BD.

4. Device allocation and program example

4.1 Device allocation

Each input of 4EX-BD is allocated a special auxiliary relay.
The ON/OFF state of each input is reflected in its corresponding special auxiliary relay.

4.2 Program example

Use a contact instruction for each special auxiliary relay.

4.3 Caution on Creation of Programs

When the END instruction of the program is executed, the input process is
completed.
REF instruction cannot be used.

When input information on 4EX-BD is used for the operand of each applied
instruction as data, only four bit data (K1M8112) can be used.

Input terminal

Special auxiliary relays

BX0

M8112

BX1

M8113

BX2

M8114

BX3

M8115

Rb(k

Ω

)

4Rp

15-Rp

BX

*1

S/S

4EX-BD

Rb

Rp

BX

*1

S/S

4EX-BD

Rb

Rp

I

Rb(k

Ω

)

6

I

 -1.5

BX

*1

S/S

4EX-BD

Rb

BX

*1

S/S

4EX-BD

Rb

I

I

K100

When BX0 (M8112) is ON, drive M0.

M1

Y000

T0

M8112

M8113

M8114

M8115

When BX2 (M8114) is ON, drive Y000.

When BX1 (M8113) is ON, drive M1.

When BX3 (M8115) is ON, drive T0.

M0

5. Specification  

5.1 Applicable PLC

The version number can be checked by monitoring D8001/D8101, as well the last three
digits indicate the version number.

Only one 4EX-BD can be used per main unit.
Never stack up two or more expansion boards.

For details on the system configuration, refer to the following manual.

→ 

FX

3S

 Series User's Manual - Hardware Edition

→ 

FX

3G

 Series User's Manual - Hardware Edition

5.2 General Specifications

The general specifications are equivalent to the PLC main unit. 
For general specifications, refer to the following manuals.

→ 

FX

3S

 Series User's Manual - Hardware Edition

→ 

FX

3G

 Series User's Manual - Hardware Edition

5.3 Power Supply Specifications

5.4 Performance Specification

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.

Before cleaning or retightening terminals, cut off all phases of the power supply
externally. Failure to do so may cause electric shock.

Before modifying or disrupting the program in operation or running the PLC,
carefully read through this manual and the associated manuals and ensure the
safety of the operation.
An operation error may damage the machinery or cause accidents.

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions. 
For repair, contact your local Mitsubishi Electric representative.

Do not drop the product or exert strong impact to it.
Doing so may cause damage.

DISPOSAL 
PRECAUTIONS

Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.

TRANSPORTATION AND 
STORAGE PRECAUTIONS

The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes. Failure to do so may cause failures in the
product. After transportation, verify operation of the product and check for damage
of the mounting part, etc.

Model name

Applicability

FX

3S

 Series PLC

Ver. 1.10 or later

FX

3G

 Series PLC

Ver. 2.20 or later

Item

Specification

Consumption 
current

5 V DC

Supply by PLC.

24 V DC

25 mA max. Supply from external power supply.

Item

Specification

Number of input points

4 points

Input connecting type

Terminal block (European type)

Input form

Sink/Source

Input signal voltage

24 V DC +20 % -15 %

Input impedance

4.3 k

Ω

Input signal current

5 mA/24 V DC

ON input sensitivity current

3.5 mA or more

OFF input sensitivity current

1.5 mA or less

Input response time

Approx. 10 ms

Input signal form

Sink

No-voltage contact input

NPN open collector transistor

Source

No-voltage contact input

PNP open collector transistor

Input circuit insulation

Photocoupler insulation

Input operation display

LED lighting when photocoupler is driven

Number of occupied 
I/O points

0 point (This number is not related to the maximum 

number of input/output points of the PLC.)

「电器电子产品有害物质限制使用标识要求」的表示方式

Note: This symbol mark is for China only.
含有有害6物质的名称,含有量,含有部品

 本产品中所含有的有害6 物质的名称,含有量,含有部品如下表所

示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T

  

26572

规定的限量要求以下。

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T

26572规定的限量要求。

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

可编程
控制器

外壳

印刷基板

×

Side

A

Side

B

JAPANESE

ENGLISH

JY997D51301C

Side

B

FX

3G

-4EX-BD

USER'S MANUAL

This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.

Effective December 2017
Specifications are subject to change without notice.

©

 2013 Mitsubishi Electric Corporation

Manual Number

JY997D51301

Revision

C

Date

December 2017

Отзывы: