This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the
Mitsubishi products; damage, secondary damage, accident compensation
caused by special factors unpredictable by Mitsubishi; damages to products
other than Mitsubishi products; and to other duties.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
•
•
•
HEAD OFFICE
HIMEJI WORKS
: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310,
JAPAN
: 840, CHIYODA CHO, HIMEJI, JAPAN
3. Installation
The extension block can be installed on a DIN46277 rail (35 mm (1.38") wide).
(Cannot be installed directly in the enclosure.)
For details, refer to the FX
3UC
Series User's Manual - Hardware Edition.
4. Example Wiring
For details, refer to the FX
3UC
Series User's Manual - Hardware Edition.
INSTALLATION
PRECAUTIONS
•
Use the product within the generic environment specifications described in
PLC main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl
2
, H
2
S, SO
2
, or NO
2
), flammable gas,
vibration or impacts, or exposed to high temperature, condensation, or rain
and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
•
Make sure to cut off all phases of the power supply externally before attempt-
ing installation or wiring work.
Failure to do so may cause electric shock.
•
Use screwdrivers carefully when performing installation work, thus avoiding
accident or product damage.
•
When drilling screw holes or wiring, make sure cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
WIRING
PRECAUTIONS
•
Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING
PRECAUTIONS
•
Connect the DC power supply wiring to the dedicated terminals specified in
this manual. If an AC power supply is connected to a DC input/output
terminal or DC power supply terminal, the PLC will burn out.
•
Connect the AC power supply wiring to the dedicated terminals specified in
this manual. If an AC power supply is connected to a DC input/output
terminal or DC power supply terminal, the PLC will burn out.
•
Do not wire vacant terminals externally.
Doing so may damage the product.
•
Perform class D grounding (grounding resistance: 100
Ω
or less) to the
grounding terminal on the main unit.
Do not use common grounding with heavy electrical systems (refer to the
manual of the PLC main unit).
•
When drilling screw holes or wiring, make sure cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
4.1 Input
4.2 Output
4.2.1
Transistor Output Type
No.
Description
External power supply 24V DC +20% -15%
Breaker, Circuit protector, Fuse etc.
Fuse
MPU main processing unit (main unit)
Class D grounding (grounding resistor 100
Ω
or less)
FX
2NC
Extension block
Contact
Three wire sensor
No.
Description
FX
2NC
Extension block
DC power supply
Emergency stop
Fuse
Load
COM X000 X001
COM
1
2
3
4
6
7
8
5
1
2
3
4
5
6
7
8
COM1
COM1
Y000
Y001
Y002
1
2
3
4
5
5
5
1
2
3
4
5
4.2.2
Relay Output Type
No.
Description
FX
2NC
Extension block
AC power supply
Emergency stop
Fuse
Load
COM1
COM1
Y000
Y001
Y002
1
2
3
4
5
5
5
1
2
3
4
5