PU/EXT key:
RUN key:
Forward run
STOP/RESET key:
MODE key:
SET key:
PU display/EXT display
Setting dial
3-digit LED monitor
RUN display
Changes the operation mode.
PU=Control panel operation mode
EXT=External operation mode
(Can be changed to reverse run
with parameter settings.)
Stop/reset (at alarm)
Changes the setting mode.
Sets the frequency setting and
parameter setting.
Shows the operation state.
Shows the parameter number
and setting value.
Shows operation mode.
Sets the frequency, and
changes the parameter setting.
Turn the setting dial, and set the number of the
next parameter to be changed.
FR
S5 2 0
0.1K
Symbol
1
2
4
None
S
3-phase input
3-phase 200V
F R - S 5 2 0 -
ⵧ
K
0.1K
0.2K
0.4K
0.75K
1.5K
2.2K
3.7K
F R - S 5 2 0 -
ⵧ
K - R
F R - S 5 4 0 -
ⵧ
K
F R - S 5 2 0 -
ⵧ
K - C
F R - S 5 4 0 -
ⵧ
K - R
F R - S 5 2 0 S -
ⵧ
K
F R - S 5 2 0 S -
ⵧ
K - R
F R - S 5 1 0 W -
ⵧ
K
F R - S 5 1 0 W -
ⵧ
K - R
Single-phase 200V
(Note)
3-phase 400V
Single-phase 100V
(Note)
Single-phase input
W
Single-phase input
(double voltage output)
100V class
200V class
400V class
Voltage
Power specifications
Inverter capacity
Remarks
Inverter type
(The inverter capacity is shown in the box)
Symbol
No. of power supply
phases, etc.
None
R
Enclosed type
RS-485 function provided
C
Totally enclosed structure
(IP40)
Symbol
Structure, communication
function, etc.
0.1K
~
Indicates capacity
(kW)
3.7K
Symbol
Inverter capacity
Type
Control panel
Basic operations (At default setting)
Model Configuration
(Note) The output is 3-phase 200V.
RU
PU
EX
RU
PU
EX
RU
PU
EX
MODE
SET
RESET
MODE
SET
MODE
SET
MOD
MOD
MOD
PU
EXT
RUN
RUN
PU
EXT
MODE
SET
STOP
RESET
PU
EXT
RUN
RUN
PU
EXT
MODE
SET
STOP
RESET
MODE
SE
RESET
MODE
SE
RESET
MODE
SE
RESET
Press the PU/EXT key to display PU.
[Example] Operating with
the control panel
Press the PU/EXT key to display PU.
[Example] Changing
the parameter setting
Starts when is pressed.
Stops when is pressed.
F and frequency flicker
Writing of the frequency
setting is completed!
RUN
STOP
RESET
1
2
3
3
4
5
6
If the parameters are set in the exter-
nal operation mode (When only EXT
is lit), Er2 (error) may appear depend-
ing on the parameter.
Monitor and
frequency setting
Parameter setting
Alarm history
Press the MODE key.
(Screen at power ON)
This screen appears.
Press the MODE key.
Press the MODE key.
Return to the monitor and
frequency setting.
Turn the setting dial.
The desired frequency set-
ting will appear.
Press the SET key within
5s after turning the dial.
Turn the setting dial.
The parameter No. will
appear.
Press the SET key after turning the dial.
The currently set number will be read out.
Turn the setting dial.
The desired setting value
will appear.
Press the SET key after
turning the dial.
Parameter No. and changed value flicker
Setting of the parameters
is completed!
●
Press the MODE key once to return to the
Alarm History screen.
●
Press the MODE key twice to return to the
Monitor and Frequency Setting screen.
After reading and changing the setting:
Note:
: Available model, : No correspondence
2
3