WIRING
3
WIRING
3.1 Terminals
3.1.1
Brake unit
Terminal Symbol
Terminal Name
Description
Rating
Main circu
it
P/+
Brake unit input
terminal
Connect to the inverter
terminal P and N.
---
N/-
PR
*1
Resistor
connection
terminal
Connect the brake resistor.
Earth (Ground)
For earthing (grounding) the
brake unit. Must be earthed
(grounded).
Cont
rol c
ir
cuit
Contact
input
BUE
Brake operation
permission
signal
Controls the brake operation.
Turning on the signal enables
brake operation.
*2
Voltage at
opening :
21 to 27VDC
Controls by open
collector output
or no voltage
contact signal.
RES Reset input
Used to reset alarm output
provided when protective
circuit is activated. Turn on the
RES signal for more than 0.1s,
then turn it off.
SD
*3
Contact input
common
Common terminal of the
control input
Brake transister driving signal
common
(for master/slave operation,
when connecting several brake
units to one inverter in parallel,
connect this signal to terminals
of other brake units.)
Master/
slave
signal
MSG
*3
Brake
transistor
driving signal
Brake transistor driving signal
terminal
(For master/slave operation,
when connecting several brake
units to on inverter in parallel,
connect this signal to terminals
of other brake units.)
---
*1
Only a brake resistor should be connected to terminal PR. Doing so may damage the
brake unit.
*2
BUE-SD is connected with a jumper in the initial status. Remove a jumper when
using this signal. (When terminals are open, brake unit is not operated.)
*3
Do not connect terminals SD, PC and MSG each other or to the ground. Doing so
may damage the brake unit.
For sink logic (initial status), terminal SD acts as the common terminal of contact
input. For source logic (initial status), terminal PC acts as the common terminal of
contact input.