1-22
MAIN CONTROLLER
Setup Options (Group 1)
Option
Default Value
#
Title of Option
Description
Range
48 V type
MC type
FC type
A, B, C, D, E
If any of these
Application
There are 5 truck modes and each has 7
option values are
Pre-Sets
option values:
changed, A thru E
# 1
(Truck Operation
Top travel speed, Acceleration rate,
will flash in order to
A
A
Mode)
Traveling power, Regen adjustment, Start
show that the truck
lift speed, Top lift speed, Tilt speed.
mode is not default
For details, see page 1-8.
setting.
# 2
Start Lift Speed
Lift speed when first lift switch is on.
1 to 10
7
5
Start lift speed cannot exceed Top lift speed.
#3
Top Lift Speed
Maximum lift speed when second lift
1 to 10
9
9
switch is on.
#4
Tilt Speed
Tilt speed is prior to Lift speed in case that
2 to 8
6
6
the two levers are simultaneously operated.
#5
Auxiliary 1 Speed
Speed setting for attachment 1
1 to 10
3
3
(1: SLOW
→
10: FAST)
#6
Auxiliary 2 Speed
Speed setting for attachment 2
1 to 10
1
1
(1: SLOW
→
10: FAST)
#7
Top Travel Speed
Maximum travel speed
Limit
48 V type: 5 to16 km/h
14
14
#8
Acceleration Rate
Choice of acceleration rate
1,2,3
2
2
(1: SLOW, 2: MIDDLE, 3: FAST)
Choice of powering characteristic
#9
Traveling Power
(1: ECONOMY, 2: STANDARD,
1,2,3
2
2
3: POWERFUL)
This option sets the time which indicates
the maintenance time for the operator. The
amount of time set by this operation is
added to the truck's hourmeter at that time
100 to 500 hours in
and the total value is stored in memory as
50-hr. increments.
the "maintenance time". When the truck's
Attached "=" to the
#10
Service Indicator
hourmeter reaches maintenance time,
value, the power
0
0
service indicator LED will turn on.
reduction function
It will flash 20 hours before maintenance
will be effective.
time. You can reduce the truck power
Selecting 0.1 makes
when the LED is solid on by selection.
the truck demo-
You can also setthe demo-mode, which
mode.
shows the ServiceIndicator function quickly.
(6 min aftersetting 0.1)
NOTE
(1) The service indicator shows the set value, not the current value. If the key switch is turned off without entering
data (without setting the switch to R), the current value is maintained. When data is entered, the current value is
replaced by the setting value on the display.
(2) The output power control function of the service indicator is the same as the output power control that is activated
when the battery voltage level drops.
(3) When the truck mode is selected, all data is replaced by the set values of the selected mode. When the set values
are changed, the truck mode indicator (A to E) flashes to notify that the settings are modified.