background image

7

5.5.  Airflow up/down direction setting

<To change the airflow up/down direction>

 

With the unit running, press the Airflow up/down button 

6

 as 

necessary.
•  Each press changes the direction. The current direction is shown at 

6

.

•  The change sequence, and the available settings, are as follows.

Airflow

Display

4 steps 

model

 Swing  1 

4

*  Note that during swing operation, the directional indication on the 

screen does not change in sync with the directional vanes on the 
unit.

*  Some models do not support directional settings.

Note:

  Available directions depend on the type of unit connected. Note also that 

some units do not provide an “Auto” setting.

  In the following cases, the actual air direction will differ from the direction 

indicated on the remote controller display.
1. While the display is showing “STAND BY” or “DEFROST”.
2. Immediately after starting heater mode (while the system is waiting for 

the operation mode change to take effect).

3. In heat mode, when room temperature is higher than the temperature 

setting.

<[Manual] To Change the Airflow’s Left/Right Direction>

*  The louver button 

7

 cannot be used.

 

Model PKFY-P·VKM-E
•  Stop the unit operation, hold the lever of the louver, 

and adjust to the desired direction.

*  Do not set to the inside direction when the unit is in 

the cooling or drying mode because there is a risk of 
condensation and water dripping.

 Caution:

To prevent falls, maintain a stable footing when operating the unit.

5.6. Ventillation

 

For LOSSNAY combination

5.6.1. For Wired Remote-controller

 To run the ventilator together with the indoor unit:

 Press the ON/OFF button 

1

.

•  The Vent indication appears on the screen (at 

8

). The ventilator 

will now automatically operate whenever the indoor unit is running.

 To run the ventilator only when the indoor unit is off:

 Press the Ventilation button 

8

 while the indoor unit is off.

•  The On lamp (at 

1

) and the Vent indication (at 

8

) come on.

 To change the ventilator force:

 Press the Ventilation button 

8

 as necessary.

•  Each press toggles the setting, as shown below.

Note:

  With some model configurations, the fan on the indoor unit may come on 

even when you set the ventilator to run independently.

5. Operation

(Low)

(High)

No display 
(Stop)

(OFF)

Содержание City Multi PKFY-P VKM-E

Страница 1: ...r gebruikt ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unit per un uso corretto e sicuro della stessa MANUAL DE INSTRUCCIONES Lea este manual...

Страница 2: ...out or leaks stop the operation of the air conditioner thoroughly ventilate the room and contact your dealer Warning The unit must not be installed by the user Ask the dealer or an authorized company...

Страница 3: ...have been locked Clean the filter indicator Comes on when it is time to clean the filter Timer indicators The indicator comes on if the corresponding timer is set For purposes of this explanation all...

Страница 4: ...ubject it to strong shocks In addition do not get the remote controller wet or leave it in a location with high humidity To avoid misplacing the remote controller install the holder included with the...

Страница 5: ...s advances the day shown at 3 Sun Mon Fri Sat 3 Press the appropriate Set Time button a as necessary to set the time As you hold the button down the time at 4 will increment first in minute intervals...

Страница 6: ...de Fan mode Heat mode Automatic cool heat operation mode Automatic operation According to a set temperature cooling operation starts if the room temperature is too hot and heating operation starts if...

Страница 7: ...temperature setting Manual To Change the Airflow s Left Right Direction The louver button 7 cannot be used Model PKFY P VKM E Stop the unit operation hold the lever of the louver and adjust to the des...

Страница 8: ...mer Menu button b so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the Timer On Off Set Day button 9 to set the d...

Страница 9: ...e only The air conditioner starts when the set time has elapsed Stop time only The air conditioner stops when the set time has elapsed Start stop times The air conditioner starts and stops at the resp...

Страница 10: ...button 4 8 Press the Operation mode Back button 2 to return to the standard control screen 9 Press the Timer On Off button 9 to start the timer countdown When the timer is running the timer value is v...

Страница 11: ...mode to stop the unit will cancel the timers If the current time has not been set the timer operation cannot be used 7 Other Functions C C TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CL...

Страница 12: ...remote controllers are connected to one group one controller must be set to sub 2 Use of clock setting CLOCK Setting the use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting...

Страница 13: ...ction setting is not used Initial setting value Operation lock setting is except On Off button Operation lock setting is All buttons The automatic mode is displayed when the operation mode is selected...

Страница 14: ...it setting press the button H The selected setting will flash and the temperature can be set Settable range Cool Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heat mode Lower limit 17 C 28 C Up...

Страница 15: ...se French Japanese CHANGE LANGUAGE Function selection Operation function limit setting Use of automatic mode setting Temperature range limit setting Limit temperature cool day mode Limit temperature h...

Страница 16: ...ating the unit without air filters can cause malfunction 10 Care and Cleaning Caution Before you start cleaning stop operation and turn OFF the power supply Indoor units are equipped with filters to r...

Страница 17: ...ter forward to remove the filter A Knob B Grille C Intake grille D Filter B A D C Cleaning the indoor unit Wipe the outside of the unit with a clean dry soft cloth Clean off any oil stains or finger m...

Страница 18: ...r unit During cool mode water may form and drip from the cool pipes and joints During heat mode water may form and drip from the heat exchanger During defrosting mode water on the heat exchanger evapo...

Страница 19: ...es Y R2 Multi S is as below Caution The use of your air conditioner outside the range of working temperature and humidity can result in serious failure Mode Indoor unit Outdoor unit PUHY PURY PUMY Coo...

Страница 20: ...be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand BG79U3...