Having trouble?

Here is the solution. (Unit is operating normally.)

Noise is louder than specifications.

 The indoor operation sound level is affected by the acoustics of the 

particular room as shown in the following table and will be higher than 
the noise specification, which was measured in an echo-free room.

High sound-
absorbing rooms

Normal rooms

Low sound-
absorbing rooms

Location 
examples

Broadcasting 
studio, music 

room, etc.

Reception room, 

hotel lobby, etc.

Office, hotel 

room

Noise levels

3 to 7 dB

6 to 10 dB

9 to 13 dB

Nothing appears in the wireless remote controller display, the display 
is faint, or signals are not received by the indoor unit unless the remote 
controller is close.

 The batteries are low.

  Replace the batteries and press the Reset button.

 If nothing appears even after the batteries are replaced, make sure 

that the batteries are installed in the correct directions (+, –).

The operation lamp near the receiver for the wireless remote controller 
on the indoor unit is flashing.

 The self diagnosis function has operated to protect the air conditioner.
 Do not attempt to repair this equipment by yourself.

  Turn off the power switch immediately and consult your dealer. Be 

sure to provide the dealer with the model name.

Warm air blows from the indoor unit intermittently when heat mode is off 
or during fan mode.

 When another indoor unit is operating in heat mode, the control 

valve opens and closes occasionally to maintain stability in the air 
conditioning system. This operation will stop after a while.
*  If this will cause an undesirable rise in the room temperature in 

small rooms, etc., stop the operation of the indoor unit temporarily.

Range of application

The range of working temperatures for both the indoor and outdoor units of the series Y, R2, Multi-S is as below.

 Caution:

The use of your air conditioner outside the range of working temperature and humidity can result in serious failure.

Mode

Indoor unit

Outdoor unit

PUHY

PURY

PUMY

Cooling

15 °C - 24 °C WB

–5 °C - 43 °C DB

–5 °C - 43 °C DB

–5 °C - 46 °C DB

Heating

15 °C - 27 °C DB

–15 °C - 15.5 °C WB

–12 °C - 15 °C WB

–12 °C - 15.5 °C WB

Note: As an applicable humidity standard for both indoors and outdoors, we recommend use within a range of 30 - 80% relative humidity.

 Warning:

If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since there may be a 
refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas leaks indoors, and 
comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated.

12. Specifications

Model

PKFY-P63VKM-E

PKFY-P100VKM-E

Power source (Voltage<V>/Frequency) 

<Hz>

~N/220-230-240/50, 220-60

Capacity  (Cooling/Heating) 

<kW>

7.1/8.0

11.2/12.5

Dimension (Height) 

<mm>

365

Dimension (Width) 

<mm>

1170

Dimension (Depth) 

<mm>

295

Net weight 

<kg>

22

Fan Airflow volume (Low-High) 

<m

3

/min>

16-20

20-25

Noise level (Low-High) 

<dB>

39-43

41-49

Model

PLFY-P20VCM-E2

PLFY-P25VCM-E2

PLFY-P32VCM-E2

PLFY-P40VCM-E2

Power source (Voltage<V>/Frequency) 

<Hz>

~N/220-230-240/50

Capacity  (Cooling/Heating) 

<kW>

2.2/2.5

2.8/3.2

3.6/4.0

4.5/5.0

Dimension (Height) 

<mm>

208 (20)

Dimension (Width) 

<mm>

570 (650)

Dimension (Depth) 

<mm>

570 (650)

Net weight 

<kg>

15.5 (3)

17.0 (3)

Fan Airflow volume (Low-Middle-High) 

<m

3

/min>

8-9-10

8-9-11

Noise level (Low-Middle-High) 

<dB>

28-31-35

28-31-37

29-33-38

30-34-39

*1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
  Cooling: Indoor 27 °C DB/19 °C WB, Outdoor 35 °C DB 
  Heating: Indoor 20 °C DB, Outdoor 7 °C DB/6 °C WB
*2 This figure ( ) indicates panel’s.

11. Troubleshooting

Содержание City Multi PKFY-P VKM-E

Страница 1: ...r gebruikt ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unit per un uso corretto e sicuro della stessa MANUAL DE INSTRUCCIONES Lea este manual...

Страница 2: ...out or leaks stop the operation of the air conditioner thoroughly ventilate the room and contact your dealer Warning The unit must not be installed by the user Ask the dealer or an authorized company...

Страница 3: ...have been locked Clean the filter indicator Comes on when it is time to clean the filter Timer indicators The indicator comes on if the corresponding timer is set For purposes of this explanation all...

Страница 4: ...ubject it to strong shocks In addition do not get the remote controller wet or leave it in a location with high humidity To avoid misplacing the remote controller install the holder included with the...

Страница 5: ...s advances the day shown at 3 Sun Mon Fri Sat 3 Press the appropriate Set Time button a as necessary to set the time As you hold the button down the time at 4 will increment first in minute intervals...

Страница 6: ...de Fan mode Heat mode Automatic cool heat operation mode Automatic operation According to a set temperature cooling operation starts if the room temperature is too hot and heating operation starts if...

Страница 7: ...temperature setting Manual To Change the Airflow s Left Right Direction The louver button 7 cannot be used Model PKFY P VKM E Stop the unit operation hold the lever of the louver and adjust to the des...

Страница 8: ...mer Menu button b so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the Timer On Off Set Day button 9 to set the d...

Страница 9: ...e only The air conditioner starts when the set time has elapsed Stop time only The air conditioner stops when the set time has elapsed Start stop times The air conditioner starts and stops at the resp...

Страница 10: ...button 4 8 Press the Operation mode Back button 2 to return to the standard control screen 9 Press the Timer On Off button 9 to start the timer countdown When the timer is running the timer value is v...

Страница 11: ...mode to stop the unit will cancel the timers If the current time has not been set the timer operation cannot be used 7 Other Functions C C TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CL...

Страница 12: ...remote controllers are connected to one group one controller must be set to sub 2 Use of clock setting CLOCK Setting the use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting...

Страница 13: ...ction setting is not used Initial setting value Operation lock setting is except On Off button Operation lock setting is All buttons The automatic mode is displayed when the operation mode is selected...

Страница 14: ...it setting press the button H The selected setting will flash and the temperature can be set Settable range Cool Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heat mode Lower limit 17 C 28 C Up...

Страница 15: ...se French Japanese CHANGE LANGUAGE Function selection Operation function limit setting Use of automatic mode setting Temperature range limit setting Limit temperature cool day mode Limit temperature h...

Страница 16: ...ating the unit without air filters can cause malfunction 10 Care and Cleaning Caution Before you start cleaning stop operation and turn OFF the power supply Indoor units are equipped with filters to r...

Страница 17: ...ter forward to remove the filter A Knob B Grille C Intake grille D Filter B A D C Cleaning the indoor unit Wipe the outside of the unit with a clean dry soft cloth Clean off any oil stains or finger m...

Страница 18: ...r unit During cool mode water may form and drip from the cool pipes and joints During heat mode water may form and drip from the heat exchanger During defrosting mode water on the heat exchanger evapo...

Страница 19: ...es Y R2 Multi S is as below Caution The use of your air conditioner outside the range of working temperature and humidity can result in serious failure Mode Indoor unit Outdoor unit PUHY PURY PUMY Coo...

Страница 20: ...be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand BG79U3...

Отзывы: