OC292-17
OUTLINES AND DIMENSIONS
5
Unit : inch(mm)
PKFY-08NAMU-A
1-11/ 32(34)
1-11/16(42.5)
1-5/8(40.5)
Unit:inch (mm)
Installation space
Details of installation plate
9-3/4(247.5)
3/32(2.5)
2-3/8(60)
5-29/32(150)
20-25/32(520)
17-23/32(450)
0
3-27/32(97.5)
7-3/32(180)
0
6-1/4(159)
0
1-3/32(27.5)
4-29/32(125)
0
2-3/32(53)
0
1-3/4(45)
26-31/32(660)
Liquid pipe
Gas pipe
(Drain pipe total 29-29/32(760))
4-11/32(110)
4-9/16(116)
11-23/32(298)
9-1/4(235)
8-1/16(205)
6-7/8(175)
0
6-11/16(170)
2-9/16(65)
1-9/16(40)
0
5-1/32(128)
4-7/8(124)
3-17/32(90)
0
6-1/4(159)
6-5/8(168)
4-7/16(113)
3-7/16(87)
5-5/16(135)
4-11/32(110)
1-3/8(35)
0
13/32(10)
0
12-29/32 (328)
4-1/32(102.5)
0
19/32(15)
0
4-13/16(122.5)
5-1/4(133)
2-27/32(72.5)
3-11/32(85)
1-7/8(47.5)
2-3/8(60)
7/8(22.5)
0
16-1/32(407.5)
12-29/32(328)
11-5/8(295)
10-1/4(260)
8-27/32(225)
7-15/32(190)
6-3/32(155)
4-23/32(120)
3-11/32(85)
0
1-3/16(30)
16-1/32(407.5)
11-23/32(298)
10-1/4(260)
8-27/32(225)
7-15/32(190)
6-3/32(155)
4-23/32(120)
3-11/32(85)
0
1-3/16(30)
13/32(10)
13/32(10)
1-31/32(50)
1-23/32(44)
0
6-7/8(175)
9-1/4(235)
6-11/16(170)
8-1/16(205)
3/16(5)
❊
1
2-3/8 (60)
5-3/4 (146)
1-15/32(37.4)
2-25/32(70.3)
Air outlet
Air outlet
Air intake
Air intake
Air intake
7-3/32(180)
Air outlet
Air intake
24-13/16(630)
1/2(13)
1/2(13)
1(25.5)
27-3/8(695)
11-5/8(295)
27/32(21.5)
32-3/32(815)
3-15/16(100) or more
5-1/8(130) or more
W
1 5-1/8(130) or more
25/32(20) or more
30-13/16(783)
6-7/32(158)
[
2-9/16~
[
2-3/4
(
[
65~
[
70)
Through hole
3.Sleeves are available on the market.
[
2-9/16
(
[
65)
Sleeve
Wiring entrance holes
Terminal block
Detailed figure dwg (ABC)
(Knock out hole)
R5/16(R8)
R19/32(R15)
R19/32(R15)
R19/32(R15)
R5/16(R8)
R15/32(R12)
R5/16(R8)
Knock out hole of right piping
Knock out hole of
remocon wiring
(Direction)
Knock of hole
Knock out hole for
remocon wiring
3/16x1-3/8(4.5x35) 4 holes
installaion plate
Knock out holt for
under piping
13/32(10)
1-31/32(50)
5/8(16)
3/32(2.5)
1-25/32 (45)
3-19/32 (91.5)
Installat plate palance point hole
Supporting piece
3/16x1-9/16 (4.5x40) 4 holes
3/16x1-15/32 (4.5x37) 4 holes
12-
[
1/8(
[
2.8)holes
4-
[
11/32(
[
9)holes
8-
[
5/32(
[
4.3) holes
87-
[
3/16(
[
5.1)holes
Piping hole
[
2-9/16(
[
65)
2-1/8(54)
Knock out hole for
left piping
45
-
31/32(24.4)
3
-
5
-
1-25/32(45)
13/32(10)
13/32(10)
1-11/32(34)
5/8 (16)
3/32(2.5)
1-31/32 (50)
5/32(4)
Air intake
Air outlet
(Direction)
Installation plate
2-1/8(54) of more
leftpiping
left-rear piping
Notes 1.Use M10 or W3/8 screw for installation plate.
2.Extension piping side.
[
5/8(
[
16) I.D
1/2F
1/4F
Drain pipe
Liquid pipe
Gas pipe
Refrigerart
piping
C
C
B
A
B
A
OC292--1.qxp 02.9.26 4:50 PM Page 17