background image

 

Thank you for purchasing the Mitsubishi program logic controller 
MELSEC-A series. 

Prior to use, please read this and relevant manuals thorougly to 
fully understand the product. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 

 SAFETY PRECAUTIONS   

(Be sure to read these instructions before use.) 

Before using this product, please read this manual and the relevant 
manuals introduced in this manual carefully and pay full attention to 
safety to handle the product correctly. 
The instructions given in this manual are concerned with this product. 
For the safety instructions of the programmable controller system, 
please read the CPU module user's manual. 
In this manual, the safety precautions are classified into two levels: 
"

WARNING" and "

CAUTION". 

WARNING

Indicates that incorrect handling may cause 
hazardous conditions, resulting in death or severe 
injury.

Indicates that incorrect handling may cause 
hazardous conditions, resulting in minor or moderate 
injury or property damage.

CAUTION

 

Under some circumstances, failure to observe the precautions given 
under "

CAUTION" may lead to serious consequences. 

Observe the precautions of both levels because they are important for 
personal and system safety. 
Make sure that the end users read this manual and then keep the 
manual in a safe place for future reference. 

[Design Precautions] 

 WARNING 

 Refer to the type MELSECNET, MELSECNET/B Data Link System 

Reference Manual for each station’s operating status when a 

communication error occurs in the network. 

Erroneous operation may result in accidents. 

 When controlling a running PLC (data modification) by connecting a 

peripheral device or GX Developer to a CPU module or by connecting 

a PC to a special function module, create an interlock circuit in the 

sequence program so that the entire system will function safely all the 

time. 

Also, before performing any other controls (e.g. program modification, 

operating status change (status control)), read the relevant manual(s) 

carefully to ensure the safety. 

Especially in control from an external device to a PLC in a remote 

location, some PLC side problem may not be resolved immediately due 

to failure of data communications. 

To prevent this, create an interlock circuit in the sequence program and 

set up corrective procedures to be taken in the event of communication 

failure between the external device and PLC CPU. 

 

 CAUTION 

 Do not bundle the control wires and communication cables with the main 

circuit or power wires, or install them close to each other. They should be 

installed at least 100mm (3.94in.) away from each other. Failure to do so 

may generate noise that may cause malfunctions. 

[Installation Precautions] 

 CAUTION 

 Use the PLC in the operating environment that meets the general 

specifications of this manual. 

Using the PLC in any other operating environments may cause electric 

shocks, fires or malfunctions, or may damage or degrade the product. 

 Insert the module fixing projection into the fixing hole in the base unit to 

press the module using the hole as the fulcrum, and then tighten the fixing 

screw with the specified torque. 

When no screw is tightened, even if the module is installed correctly, it may 

cause malfunctions, a failure or a drop of the module. 

 Tighten the screws within the range of specified torque. If the screws are 

loose, it may cause the module to fallout, short circuits, or malfunction. If the 

screws are tightened too much, it may cause damage to the screw and/or 

the module, resulting in fall out, short circuits or malfunction. 

 Completely turn off the externally supplied power used in the system before 

mounting or removing the module. Failure to do so may damage the 

product. 

 Do not directly touch the conducting parts and electronic parts of the 

module. This may cause the module to malfunction or fail. 

[Wiring Precautions] 

 WARNING 

 Completely turn off the externally supplied power used in the system when 

installing or placing wiring. 

Failure to do so may cause electric shocks or damage the product. 

 

 CAUTION 

 Solder coaxial cable connectors properly. Incomplete soldering may result 

in malfunctioning. 

 Be careful not to let foreign particles such as chaff and wire chips get inside 

the module. They may cause a fire, mechanical breakdown or malfunction. 

 The top surface of the module is covered with a protective film to prevent 

foreign objects such as wire chips from entering the module during wiring 

work. Do not remove this film until all the wiring work is complete. Before 

operating the system, be sure to remove the film to provide adequate heat 

ventilation. 

 Make sure to place the communication and power cables to be connected 

to the module in a duct or fasten them using a clamp. If the cables are not 

placed in a duct or fastened with a clamp, their positions may become 

unstable and may move, or they may be pulled inadvertently. This may 

damage the module and the cables or cause the module to malfunction 

because of faulty cable connections. 

[Setup and Maintenance Precautions] 

 CAUTION 

 Please read this manual thoroughly and confirm the safety before starting 

online operations (especially, program modifications, forced outputs, and 

operating status modifications), which are performed by connecting the GX 

Developer via the MELSECNET network system to a running CPU module 

of other station. Performing incorrect online operations may damage the 

machinery or result in accidents. 

 Never disassemble or modify the module. This may cause breakdowns, 

malfunctions, injuries or fire. 

 Use any radio communication device such as a cellular phone or a PHS 

phone more than 25cm (9.85 inch) away in all directions of the PLC. 

Not doing so can cause a malfunction. 

 Shut off all phases of the external power supply in the system before 

mounting or dismounting the module. Failure to do so may cause failure or 

malfunction of the module. 

 Do not touch the terminals while the power is on. Doing so may cause 

malfunctions. 

 Shut off all phases of the external power supply in the system before 

cleaning or retightening the terminal screws or module fixing screws. 

Not doing so may cause failure or malfunction of the module. 

If the screws are loose, it may cause the module to fallout, short circuits, or 

malfunction. 

If the screws are tightened too much, it may cause damages to the screws 

and or/the module, resulting in fall out, short circuits or malfunction. 

 Before touching the module, be sure to touch grounded metal, etc. to 

discharge static electricity from human body, etc. 

Failure to do so may cause the module to fail or malfunction. 

[Disposal Precautions] 

 CAUTION 

 When disposing of this product, treat it as industrial waste. 

 

Data link module

type A1SJ71AP21(-S3)

/AR21

User’s Manual

(Hardware)

A1SJ71AP21 

A1SJ71AP21-S3

A1SJ71AR21 

1994 MITSUBISHI ELECTRIC CORPORATION 

MODEL 

A1SJ71AP21/R21 

(H/W)-U-E 

MODEL 

CODE 

13JE58 

IB(NA)-66480-C(1112)MEE 

Содержание A1SJ71AP21

Страница 1: ...t short circuits or malfunction If the screws are tightened too much it may cause damage to the screw and or the module resulting in fall out short circuits or malfunction Completely turn off the externally supplied power used in the system before mounting or removing the module Failure to do so may damage the product Do not directly touch the conducting parts and electronic parts of the module Th...

Страница 2: ... PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications of the PRODUCTs are required For details please contact the Mitsubishi representative in your...

Страница 3: ...ion when purchasing these products REMARK 1 The overall loop distance refers to the distance from the master station sending port to the master station receiving port via slave stations For both the fiber optic cables and coaxial cables The overall loop distance is a maximum of 10km 32810ft 2 For general specifications of the date link system refer to the user s manual for the PLC CPU module that ...

Страница 4: ...optical fiber cables IN OUT IN OUT IN OUT IN OUT IN Connected to previous station s OUT OUT Connected to next station s IN FRONT Master station No 1 FRONT FRONT FRONT No 2 5 2 Connecting coaxial cables IN OUT F SD R SD R RD F RD FRONT IN R RD F SD F RD OUT R SD IN R SD Connected to previous station s OUT R RD IN F RD Connected to previous station s OUT F SD OUT F SD Connected to next station s IN ...

Отзывы: