'21 • SRK-T-324
-
99
-
Indoor unit running status
Signal from the optional device
Run/Stop
During SW operation
Run signal by timer
control
Stop signal by timer
control
Before the OFF TIMER setting time elapses
(Before the SLEEP TIMER setting time elapses)
Run
➾
Stop
Run
(No change)
Run
➾
Stop
ON TIMER on standby
On standby
➾
Run
On standby
➾
Run
On standby
➾
Stop
Warming-up running
Run
➾
Stop
Run
(No change)
Run
➾
Stop
Running
Run
➾
Stop
Run
(No change)
Run
➾
Stop
Stopped
Stop
➾
Run
Stop
➾
Run
Stop
(No change)
After the ON time of the WEEKLY TIMER
(Running)
Run
➾
Stop
Run
(No change)
Run
➾
Stop
After the OFF time of the WEEKLY TIMER
(Stopped)
Stop
➾
Run
Stop
➾
Run
Stop
(No change)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
•TIMER LED remains OFF
•Running continues during the Stop period (
②
→
③
).
Ex. 1
Ex. 2
WEEKLY TIMER
Timer control signal
from the wireless
remote control
RUN LED
TIMER LED
RUN LED
TIMER LED
①
Standby
running
②
Warming-up
running
▽
(Running)
Timer setting time elapsed
③
Timer ON (→Running)
(Stop)
Timer setting time elapsed
④
Timer OFF
(→Stopped)
▽
Operation when an option is not connected
Operation when an option is connected
•TIMER LED remains OFF
•Air conditioner turns ON at the same time the control signal from the wireless
remote control is received
•Operation does not stop at the OFF time.
①
Timer ON
(→Running)
▽
(Running)
Timer setting time elapsed
②
Timer ON (→Stopped)
▽
(Stop)
Timer setting time elapsed
③
Timer ON (→Running)
Operation when an option is not connected
Operation when an option is connected
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Ex. 3
Timer control signal
from an optional device
Timer setting time elapsed
Ⓐ
Run signal
▽
Timer setting time elapsed
Ⓑ
Stop signal
▽
Timer control signal
from the wireless
remote control
①
Standby running
▽
②
Warming-up running
▽
(Running)
Timer setting time elapsed
(Stop)
Timer setting time elapsed
④
Timer OFF(Stopped)
RUN LED
TIMER LED
RUN LED
TIMER LED
•Stops at the OFF time of the timer control of the optional device, regardless of the setting order.
Cancels the timer of the indoor unit.
Ex. 4
Timer control signal
from an optional device
Timer setting time elapsed
Ⓐ
Stop signal
▽
Timer setting time elapsed
Ⓑ
Run signal
▽
Timer control signal
from the wireless
remote control
(Running)
Timer setting time elapsed
①
Timer ON
(→Running)
(Stop)
Timer setting time elapsed
②
Timer ON
(→Stopped)
(Stop)
Timer setting time elapsed
③
Timer ON
(→Running)
(3) Indoor unit operation status before and after receiving a signal from the
wireless remote control
[Indoor unit with a timer setting enabled from an optional device]
For each indoor operation status including timer settings, the indoor run/stop status when the run/stop signal
was changed due to operation or timer settings from an optional device is shown in the table below.
Operations that cancel the wireless remote control timer setting through an operation from an optional device are
shown with .
Содержание WF-RAC
Страница 1: ...WIRELESS LAN INTERFACE WF RAC TECHNICAL MANUAL Manual No 21 SRK T 324 ...
Страница 2: ......
Страница 36: ... 21 SRK T 324 34 9 APPLICATION OPERATION MANUAL Smart M Air Operation Manual EN RKZ012A107 RKZ012A107 B ...
Страница 50: ... 21 SRK T 324 48 15 Figure 3 21 Figure 3 22 Figure 3 23 Enter a new air conditioner name and tap YES ...
Страница 71: ... 21 SRK T 324 69 36 Canceling demo mode Figure 11 2 In the demo mode Cancel demo Exits the demo mode ...
Страница 73: ... 21 SRK T 324 71 38 Figure 12 3 ...