3
-
Item
Model
SRK71CF-BN
SRC71CF-BN
Cooling capacity
kW
7.03 / 7.03
Cooling power input
kW
2.12 / 2.27
Energy efficiency ratio
Btu/hW
11.33 / 10.58
Rating current
A
10.6 / 10.4
Cooling capacity
kW
6.3 / 6.3
Cooling power input
kW
2.48 / 2.60
Energy efficiency ratio
Btu/hW
8.67 / 8.26
Rating current
A
12.4 / 11.9
Power source
1 Phase, 220-240V, 50Hz
Noise level
Cooling Sound level
dB
Hi 45, Me 42, Lo 39
55
Exterior dimensions
Height
×
Width
×
Depth
mm
318
×
1098
×
248
750
×
880
×
340
Color
Yellowish white
Stucco white
Net weight
kg
15
67
Refrigerant equipment
Compressor type & Q’ty
–
2JS386D5BC02 (Rotary type)
×
1
Motor
kW
–
1.8
Starting method
–
Line starting
Heat exchanger
Slit fins & inner grooved tubing
Straight fin & inner grooved tubing
Refrigerant control
Capillary tubes + Electric expansion valve
Refrigerant
(3)
kg
R22 1.75 (Pre-charged up to the piping length of 7m)
Refrigerant oil
R
0.7 (ATMOS NM56M or SUNISO 4GDID)
Deice control
Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
46
85
Air flow (at High)
(Cooling)
CMM
20.5
60
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote control
–
Room temperature control
Microcomputer thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
15.88 (5/8
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.70m
Gas line : 0.63m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source supply
Terminal block (Screw fixing type)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter
×
1, Photocatalytic washable deodorizing filter
×
1)
Optional parts
Wired-Remote control
Notes (1) The data are measured at the following conditions.
Model SRK71CF-BN (Indoor unit)
SRC71CF-BN (Outdoor unit)
(2) The operation data are applied to the 220/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 7 to 25m, add 25g refrigerant per meter.
Refrig
erant
piping
Compressor: overheat protection, Frost protection, Serial signal error protection, Indoor fan motor error
protection
(220/240V)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
29ºC
19ºC
46ºC
24ºC
ISO-T3, SASO 385/386
The piping length is 7.5m.
ISO-T1
(JIS)
ISO-T3
(SASO)