20
−
3. Quick reference of menu items
Quick reference of menu items
It is necessary to input the Administrator password for menu items showing.
Setting and display items
Details
Useful functions
,QGLYLGXDOÀDSFRQWURO
Set the moving range (upper and lower limit positions) of the
ÀDSDWHDFKEORZRXWOHWRI,8
Set also the left limit position-rights limit position if FDK is
used.
page 31
Anti draft setting
If the panel with anti draft is used, set enable/disable of the
each operation mode and anti draft operation of each blow
outlet.
page 35
Timer
Set ON timer by
hour
Set the time to operate the unit after stopping the operation
within the range of 1 - 12 hours (at 1-hour intervals).
page 44
Set OFF timer by
hour
Set the time to stop the operating unit within the range of 1
- 12 hours (at 1-hour intervals).
page 46
Set ON timer by
clock
Set the clock time to start operation.
■
The time can be set at 5-minute intervals.
■
It can be selected from once (only one day) or every time
(every day).
*
Clock setting is necessary to set the timer.
page 47
Set OFF timer by
clock
Set the time to stop operation.
■
The time can be set at 5-minute intervals.
■
It can be selected from once (only one day) or every time
(every day).
*
Clock setting is necessary to set the timer.
page 49
Favorite setting
Administrator password
Set each operation mode and setting temperature, fan speed,
ÀDSGLUHFWLRQIRU)DYRULWHVHWWLQJRU)DYRULWHVHWWLQJ
page 58
Weekly timer
On timer or Off timer on weekly basis can be set.
■
8-operation patterns per day can be set at the maximum.
■
The time can be set at 5-minute intervals.
■
Holiday setting (including temporary day off) is available.
*
Clock setting is necessary to set the time.
page 50
Home leave mode
Administrator password
When the unit is not used for a long period of time, the room
temperature is maintained at a moderate level, avoiding
extremely hot or cool temperatures.
■
Cooling or heating is operated according to the outdoor
temperature and the set temp.
■
Set temp and fan speed can be set.
page 54
External ventilation
The ventilation is turned on or off if ventilation equipment is
attached.
page 37
Select the language
Set the language to be displayed on the R/C.
page 73
Silent mode control
The period of time to operate the unit by prioritizing the
quietness can be set.
■
Start and end can be set for the silent mode.
page 72
Energy-saving setting
Administrator password
Sleep timer
Set the time period from start to stop of operation.
■
The selectable range of setting time is from 30 to 240
minutes (at 10-minute intervals).
■
When the setting is “Enable”, this timer will activate
whenever any operation starts.
page 25
Peak-cut timer
Set the times to start and stop the capacity limiting operation
and the peak-cut %.
■
4 operation patterns per day can be set at the maximum.
■
The setting time can be changed at 5-minute intervals.
■
The selectable range of peak-cut % is from 0.40 to 80% (at
20% intervals).
■
Holiday setting (including temporary day off) is available.
*
Clock setting is necessary.
page 26
Automatic temp set back
It returns to the set temperature when the set time is counted
up.
■
The selection range of the set time is from 20 to 120
minutes (at 10-minute intervals).
page 29
Motion sensor control
If the motion detector is used, set enable/disable of Power
Control and autosave.
page 30