Error code
Remote controller:
7-segment display:
LED
Green
Red
Indoor
Outdoor
Content
–
83
–
E38
E38
Outdoor air temperature
thermistor anomaly (Tho-A)
Keeps flashing Stays Off
Keeps flashing 1 time flash
1. Applicable model
5. Troubleshooting
Outdoor unit
Diagnosis
Countermeasure
Is the
connector of
thermistor connected
properly?
Are the
characteristics of
thermistor
OK?*1
*1
Check several times to prove any poor connection
Temperature-resistance characteristics of
outdoor air temperature thermistor (Tho-A)
Save data for 30 minutes before stopping in Mente PC
YES
NO
NO
YES
Temperature (°C)
0
10
20
30
40
50
60
70
80
90
100
-20
-10
0
10
20
30
40
50
Temperature thermistor resistance (kΩ)
Check and save the data of
operating condition.
Check the conditions whether
it occurs immediately after the
power on or during operation
or stopping.
Check the sensed value.
Compare the temperature
on Mente PC with actual
measured value.
Insert the connector
securely
Replace thermistor
(Tho-A).
Replace outdoor control
PCB.
2. Error detection method
Detection of anomalously low
temperature (resistance) of
Tho-A
3.
Condition of error displayed
•
If -30°C or lower is detected for 5 seconds
continuously within 2-minutes to 2-minutes
20-seconds after the compressor ON, the
compressor stops. And after 3-minutes delay,
the compressor starts again automatically, but if
this anomalous temperature is detected 3 times
within 40 minutes after the initial detection.
•
If -30°C or lower is detected for 5 seconds
continuously within 20 seconds after power ON.
4. Presumable cause
• Broken thermistor harness or
the internal wire of sensing
section (Check the molded
section as well)
• Disconnection of thermistor
harness connection (connector)
• Outdoor control PCB anomaly
Note:
Содержание FDE112KXE6A
Страница 104: ... 102 ...
Страница 106: ... 104 Table 1 Switch Setting Model JSW10 JSW11 1 2 3 4 All models INV1 OFF ON OFF OFF INV2 OFF ON OFF ON ...
Страница 110: ... 107 C PJF000Z053 3 ELECTRICAL WIRING 3 1 Indoor unit a Ceiling cassette 4 way type FDT Models All models ...
Страница 111: ... 108 b Ceiling cassette 4 way Compact type FDTC Models All moddels B PJA003Z331 ...
Страница 112: ... 109 c Ceiling cassette 2 way type FDTW Models FDTW28KXE6 45KXE6 56KXE6 B PJB001Z560 ...
Страница 113: ... 110 Models FDTW71KXE6 90KXE6 B PJB001Z561 ...
Страница 114: ... 111 Models FDTW112KXE6 140KXE6 B PJB001Z562 ...
Страница 115: ... 112 d Ceiling cassette 1 way type FDTS Model FDTS45KXE6 A PJC001Z195 ...
Страница 116: ... 113 Model FDTS71KXE6 A PJC001Z196 ...
Страница 117: ... 114 e Ceiling cassette 1 way compact type FDTQ Models All models A PJC001Z190 ...
Страница 118: ... 115 Models All models Duct panel A PJC001Z240 ...
Страница 120: ... 117 f Duct connected High static pressure type FDU Models 90KXE6 112KXE6 140KXE6 B PJD001Z229 ...
Страница 121: ... 118 Models FDU224KXE6 280KXE6 B PJD001Z230 ...
Страница 123: ... 120 Models FDUM112KXE6 140KXE6 B PJR002Z259 ...
Страница 124: ... 121 h Duct connected Ultra thin Low static pressure type FDQS Models All models C PJC001Z200 ...
Страница 125: ... 122 i Wall mounted type FDK Models FDK22KXE6 28KXE6 36KXE6 45KXE6 56KXE6 B PHA000Z983 ...
Страница 126: ... 123 Models FDK71KXE6 B PHA000Z984 ...
Страница 127: ... 124 j Ceiling suspended type FDE Models FDE36KXE6A 45KXE6A 56KXE6A B PFA003Z826 ...
Страница 128: ... 125 Models FDE71KXE6A 112KXE6A 140KXE6A B PFA003Z827 ...
Страница 129: ... 126 k Floor standing with casing type FDFL Models All models B PGD000Z053 ...
Страница 130: ... 127 l Floor standing without casing type FDFU Models All models A PGD000Z058 ...
Страница 131: ... 128 m Duct Connected Compact and Flexible type FDUH Models All models A PJC001Z255 ...
Страница 132: ... 129 3 2 Outdoor unit Models FDC335KXE6 K 400KXE6 450KXE6 504KXE6 560KXE6 560KXE6 K 615KXE6 680KXE6 PCB003Z060 ...
Страница 138: ... 135 ...
Страница 139: ... 136 ...
Страница 143: ... 140 b ...
Страница 144: ... 141 ...
Страница 191: ... 188 5 4 Installation of outdoor unit ...
Страница 193: ... 190 ...
Страница 194: ... 191 ...
Страница 195: ... 192 ...
Страница 196: ... 193 ...
Страница 197: ... 194 ...
Страница 198: ... 195 ...
Страница 199: ... 196 ...
Страница 200: ... 197 ...
Страница 201: ... 198 ...
Страница 202: ... 199 ...
Страница 203: ... 200 ...
Страница 204: ... 201 ...
Страница 205: ... 202 ...
Страница 206: ... 203 ...
Страница 207: ... 204 ...
Страница 208: ... 205 ...
Страница 210: ... 207 ...
Страница 211: ... 208 ...
Страница 212: ... 209 ...
Страница 215: ... 212 2 model type DIS model type HEAD ...
Страница 216: ... 213 2 2 ...
Страница 217: ... 214 2 2 2 2 2 ...