10-3. INSTRUCTION OF TROUBLESHOOTING
Indoor unit operates.
Outdoor unit does not
operate.
If blinking of OPERATION INDI-
CATOR lamp cannot be checked,
it can be checked with failure
mode recall function.
Indoor unit operates.
Outdoor unit does
not operate normally.
Indoor unit does
not receive the
signal from re-
mote controller.
OPERATION INDICATOR
lamp on the indoor unit is
blinking ON and OFF.
Outdoor unit
operates only
in Test Run
operation.
Outdoor unit
does not
operate even
in Test Run
operation.
Unit does not
operate nor-
mal operation
in COOL or
HEAT mode.
Indoor unit
operates, when
EMERGENCY
OPERATION
switch is pressed.
Indoor unit does
not operate, when
EMERGENCY
OPERATION
switch is pressed.
Check room
temperature
thermistor.
Refer to 10-
7. "Test point
diagram and
voltage".
Refer to "How
to check
inverter/com-
pressor".
Refer to
"Check of R.V.
coil".
Refer to 10-6.
"Check of remote
controller and
indoor electronic
control P.C. board".
1. Check indoor/out-
door connecting wire.
(Check if the power is
supplied to the indoor
unit.)
2. Refer to 10-6. "Check
of indoor P.C. board
and indoor fan motor".
Start
"Test Run operation" means the
operation within 30 minutes af-
ter EMERGENCY OPERATION
switch is pressed.
Refer to outdoor unit service manual.
Upper lamp
Blink on and
off at 0.5-sec-
ond intervals
Cause:
Indoor/Outdoor
unit
• Miswiring or
trouble of se-
rial signal
Upper lamp
2-time blink
Cause:
Indoor unit
• Trouble
of room
temperature
/ indoor coil
thermistor
Upper lamp
3-time blink
Cause:
Indoor unit
• Trouble of
indoor fan
motor
Upper lamp
4-time blink
Cause:
Indoor unit
• Trouble
of indoor
unit control
system
Upper lamp
5-time blink
Cause:
Outdoor unit
• Outdoor
power sys-
tem abnor-
mality
Upper lamp
6-time blink
Cause:
Outdoor unit
• Trouble of
thermistor in
outdoor unit
Upper lamp
7-time blink
Cause:
Outdoor unit
• Trouble of
outdoor con-
trol system
Upper lamp
14-time blink
or more
Cause:
Outdoor unit
• Other ab-
normality
Refer to 10-
6. "How to
check mis-
wiring and
serial signal
error".
Check room
temperature
thermistor
and indoor
coil thermis-
tor. Refer to
10-7."Test
point diagram
and voltage".
Refer to 10-
6. "Check
of indoor fan
motor".
Replace the
indoor elec-
tronic control
P.C. board.
Refer to
"How to
check
inverter/com-
pressor".
Refer to
"Check of
outdoor ther-
mistors".
Replace the
inverter P.C.
board or
the outdoor
electronic
control P.C.
board.
Check "Flow
chart of the
detailed
outdoor unit
failure mode
recall func-
tion."
NOTE
: The indoor unit does not operate by smartphone, refer to 10-3.2."Check of Wi-Fi Interface".
1. Check of the unit.
OBH788C
Содержание WSH-AP42WI
Страница 13: ...13 MSZ AP50VG E1 EN1 ER1 E2 EN2 MSZ AP50VG ET1 ET2 OBH788C ...
Страница 14: ...14 MSZ AP60VG E1 ER1 E2 MSZ AP71VG E1 ER1 E2 MSZ AP60VG ET1 ET2 MSZ AP71VG ET1 ET2 OBH788C ...
Страница 16: ...16 MSZ AP50VGK E1 EN1 ER1 E2 EN2 MSZ AP50VGK ET1 ET2 OBH788C ...
Страница 17: ...17 MSZ AP60VGK E1 ER1 E2 MSZ AP71VGK E1 ER1 E2 MSZ AP60VGK ET1 ET2 MSZ AP71VGK ET1 ET2 OBH788C ...