Page 8-3
Horizontal Deflection and HV Key Points
• The Horizontal Drive from the VCJ drives both the Horizontal and HV Outputs.
• The saturable reactor transform, T501, is controlled by the HV Regulation circuit.
• The FBT generates the HV, Focus, 230V, 34V, and CRT filament supplies.
• A sample of the HV is derived from the CR Block for the HV Regulation and X-Protect circuits.
• The capacitive divider in the CR Block provides the drive signal for the PCB-D-REG.
• The voltage from pin 8 of the FBT is used by the ACL and Beam Current Protect circuits.
• T519 is the source for the Convergence ±24 volt supplies.
• The pulse from Q5AD0 is the Horizontal Yokes drive, and is used by the Horizontal Blanking and
CRT Protect circuitry.
• The voltage at the emitter of Q5AD0 is monitored by the SHORT line, through Q533.