background image

 

 

 

 

 

Содержание VL-100U-E

Страница 1: ...have the following significance This applies to mishandling or mis operation of the product which may lead to a fatal or serious injury This applies to mishandling or mis operation of the product which will lead to an injury or damage to your home household effects etc The graphic symbols have the following signigicance Prohibited Do NOT disassemble Do NOT touch Use is prohibited wherever water is...

Страница 2: ...ng or another malfunction occurs turn the unit off and remove the power plug Continuing operation may result in breakdown electric shock or fire CAUTION Do not place combustion equipment in the direct path of the air from the unit Incomplete combustion may result in accidents Do not use the unit in excessively hot areas areas of oily smoke or near open flames Fire may result A fan rotates inside t...

Страница 3: ...e to the Lossnay Core stop the unit if the outside temperature falls below 10 C or the room s humidity rises above 40 Shutter prevents outside air being blown in when unit is off Cord Power plug Main unit Lossnay Core Heat exchanger Air filter Screw Operation indicator Panel Open Close Open Close Knob Cord Operation indicator Once Twice Three times HI operation LO operation Operation indicator lig...

Страница 4: ...ve the panel Loosen the screw holding the panel and pull the panel forward to remove it Panel 3 Remove the Lossnay Core Pull it forward to remove it Lossnay Core 4 Remove the air filter Remove it from the catches on the Lossnay Core Cleaning Use a vacuum cleaner to remove dust You can also rinse it with lukewarm water or wash it with a neutral detergent solution Replacement Replace the filter with...

Страница 5: ...ances may cause deterioration or discoloration Paint thinner alcohol benzene gasoline kerosene sprays alkaline detergents or chemical cleansers Note 1 Air filter Lossnay Core 1 Attach the air filter to the Lossnay Core 2 Push in the Lossnay Core with the air filter at the bottom Lossnay Core Air filter 2 Panel attachment checking 1 Hang the panel at the top of the main unit and hold the bottom whi...

Страница 6: ...d to prevent an accident from occurring Problem Cause Check the following Check the power plug Check that a circuit breaker Unit does not operate No power to main unit fuse has not tripped Check a power failure has not occurred Panel or filter is not attached Re attach panel or filter securely Unit is making a strange noise Filter is clogged Clean filter Shutter is closed Open shutter Less air tha...