LED INDICATIONS AND SELF DIAGNOSTICS
The front panel Status LED provides an indication of the set’s operation and the possible cause of a malfunction.
SELF DIAGNOSTICS
A blinking red and yellow Status LED will indicate an Error Code that can help determine the cause of a circuit
failure.
•
The number of Red blinks indicates the value of the MSD (tens digit) of the Error Code.
•
The number of Yellow blinks indicates the value of the LSD (ones digit) of the Error Code.
Example: If the Error Code is “27”, the LED will continuously blink Red two times, followed by blinking Yellow
seven times.
See the following page for a list of Error Codes.
To perform a System Reset, press and hold the side Power button for 10 seconds. Or, unplug the set for 10 sec-
onds then restore power
NORMAL INDICATIONS
STATUS LED Indication
Condition
Off Off
(Standby)
Green Power
On
Slow Blinking Green
Power Off with Timer Set
Fast Blinking Green
Power On Boot-up, AC Interrupted, System
Reset or Software Update (Wait from between
45 seconds to several minutes for blinking to
stop before proceeding)
STATUS LED Indication
Condition
ABNORMAL INDICATION
Blinking Red then Blinking Yellow
Circuit Failure (See Self Diagnostics)
Number of Red Blinks
Number of Yellow Blinks
2
7
Error Code: 27
Содержание Unisen LT-40164
Страница 2: ......
Страница 51: ...Page 51 MODELS LT 55154 LT 40164 LT 46164 LT 55164 LT 46265 LT 55265 CIRCUIT BLOCK DIAGRAMS ...
Страница 52: ...Page 52 MODELS LT 55154 LT 40164 LT 46164 LT 55164 LT 46265 LT 55265 ...
Страница 54: ...Page 54 MODELS LT 55154 LT 40164 LT 46164 LT 55164 LT 46265 LT 55265 ...
Страница 55: ...Page 55 MODELS LT 55154 LT 40164 LT 46164 LT 55164 LT 46265 LT 55265 ...