Page 19
MODELS: LT-40151 / LT-46151 / LT-52151 / LT-40153 / LT-46153 / LT-52153 / LT-46249 / LT-52249
OPTION MENU
1. Press the <MENU> button on the remote control.
2. Press the buttons <2-4-7-0>. The screen will display the Option Menu.
NOTE:
If the ISF (ADV) video settings have been calibrated, see the section
Backup / Restore ISF Settings
before performing Reset and Initialization procedures.
DIGITAL SIGNAL STRENGTH
1. Tune to a Digital Channel.
2. From the Option Menu, scroll down and highlight “Digital Signal Strength.”
3. Press <ENTER>. The screen will display the Digital Signal Strength Menu.
SNR Recommended Levels:
8VSB = 16 to 33
64 QAM = 22 to 35
256 QAM = 27 to 38
OPTION MENU
Option Menu
<MENU><2-4-7-0>
Initialize
Power Restore
OFF
Production Mode
OFF
Digital Signal Strength
<1~9>
NetCommand Software
Vxx xxx.xx
Total hours of use
0
Digital Signal Strength Menu
"Digital Signal Strength" <ENTER>
Tuner
Frequency(MHz)
749
Signal Level
<1~9>
Modulation
8VSB Air
Carrier Lock
Locked
SNR
29.09
Correctable errors
0
Un Correctable errors
0