Page 11
MODELS: LT-40151 / LT-46151 / LT-52151 / LT-40153 / LT-46153 / LT-52153 / LT-46249 / LT-52249
NET/ML Assembly Removal** (LT-46249 & LT-52249 Only)
1) Disconnect all electrical connectors from PWB-NET/ML and PWB-ML-POWER.
2) Remove screws (A).
3) Lift Net/ML Assembly up and off.
PWB-ML-POWER Replacement (LT-46249 & LT-52249 Only)
NOTE: Removal of the NET/ML-Assembly is not required for PWB-ML-POWER replacement.
1) Disconnect all electrical connectors from PWB-ML-POWER.
2) Remove screws (B).
3) Lift away the PWB-ML-POWER.
4) Reverse the procedure for installation.
DISASSEMBLY & PARTS REPLACEMENT
(CONTINUED)
A
A
NET/ML
ASSEMBLY
PWB-NET/ML
PWB-ML-POWER
B
PWB-ML-POWER