Service Manual
Trium 110
Version A
Date: 05/02
7/22
+
:
(
:
FAX
:
Mitsubishi Electric Telecom Europe S.A.
After Sales Services
Z.A. Pigeon Blanc, 35 370 St Germain du Pinel France
+33 (0)2 23 55 16 30
+33 (0)2 99 75 71 62
2.3 Disassembly and Assembly Instruction
2.3.1
Disassembly Instruction
The procedure for mobile disassembly is described in the instruction
GFZ13136904
– TRIUM 110
Disassembly (M6A+ Cupid)
.
2.3.2
Assembly Instruction
The procedure for mobile assembly is described in the instruction
GFZ13136903 – TRIUM 110
Assembly (M6A+ Cupid)
.
3 Download
The data are divided in two parts: the software and the settings.
Currently the Mitsubishi software ( .bin file ) is downloaded into the Flash and the setting ( . pso file ) is
downloaded into an EEPROM or Serial Flash.
The M6A+ mobiles does not use EEPROM but a Flash Data and the setting are not in
.pso
extension
but in
.psb
(as M6A). The main consequence of this change is that the
new setting file . psb
MUST
BE DOWNLOADED WITH IPL TRIUM.
In conclusion, with the M6A product, the software and the setting can be downloaded in the same time
by using IPL Trium.
3.1 Download of Software and settings
The configuration to download software is :
Launch
MT ToolsV103.02
or higher, select the “
Mobile Type M5-M6A
” and then launch
IPL Trium
in
download/download software menu.
To COM 1
Professional PC cable M5
MA/NE : FK8T000410
Main unit
switched OFF
MT Tool
V103.02
or higher