background image

En-1

● OPERATING INSTRUCTIONS ●

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

Marks and their meanings

 WARNING :

Incorrect  handling  could  cause  serious  hazard,  such  as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 

on the conditions.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

 :  Never insert your fi nger or stick, etc.

 :  Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.

 :  Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

S

AFETY PRECAUTIONS

C

ONTENTS

 WARNING

Do not connect the power cord to an intermediate point, 

use an extension cord, or connect multiple devices to a 

single AC outlet.

•  This may cause overheating, fi re, or electric shock.

Make sure the power plug is free of dirt and insert it se-

curely into the outlet.

•  A dirty plug may cause fi re or electric shock.

Do not bundle, pull, or modify the power cord, and do not 

apply heat or place heavy objects on it.

•  This may cause fi re or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the 

power plug during operation.

•  This may create sparks, which can cause fi re.

•  After the indoor unit is switched OFF with the remote con-

troller, make sure to turn the breaker OFF or disconnect the 

power plug. 

Do not expose your body directly to cool air for a prolonged 

length of time.

•  This could be detrimental to your health.

The unit should not be installed, relocated, disassembled, 

altered, or repaired by the user.

•  An improperly handled air conditioner may cause fi re, electric 

shock, injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced 

by the manufacturer or its service agent in order to avoid a 

hazard.

When installing, relocating, or servicing the unit, make 

sure that no substance other than the specifi ed refrigerant 

(R410A) enters the refrigerant circuit.

•  Any presence of foreign substance such as air can cause 

abnormal pressure rise and may result in explosion or in-

jury.

•  The use of any refrigerant other than that specifi ed for the 

system will cause mechanical failure, system malfunction, 

or unit breakdown. In the worst case, this could lead to a 

serious impediment to securing product safety.

This appliance is not intended for use by persons (includ-

ing children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concern-

ing use of the appliance by a person responsible for their 

safety.
Children should be supervised to ensure that they do not 

play with the appliance.

  

Do not insert your fi nger, a stick, or other objects into the 

air inlet or outlet.

•  This may cause injury, since the fan inside rotates at high 

speeds during operation.

  

In case of an abnormal condition (such as a burning smell), 

stop the air conditioner and disconnect the power plug or 

turn the breaker OFF.

•  A continued operation in the abnormal state may cause a 

malfunction, fi re, or electric shock. In this case, consult your 

dealer.

When the air conditioner does not cool or heat, there is 

a possibility of refrigerant leakage. In this case, consult 

your dealer. If a repair involves recharging the unit with 

refrigerant, ask the service technician for details.

•  The refrigerant used in the air conditioner is safe. Normally, 

it does not leak. However, if refrigerant leaks and comes in 

contact with a heat source such as a fan heater, kerosene 

heater, or cooking stove, it will create a harmful gas.

The user should never attempt to wash the inside of the 

indoor unit. Should the inside of the unit require cleaning, 

contact your dealer.

•  Unsuitable detergent may cause damage to plastic material 

inside the unit, which may result in water leakage. Should 

detergent come in contact with electrical parts or the motor, 

it will result in a malfunction, smoke, or fi re.

 

SAFETY PRECAUTIONS 

1

 

NAME OF EACH PART 

3

 

PREPARATION BEFORE OPERATION 

4

 

SELECTING OPERATION MODES 

5

 

FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

6

 

ECONO COOL OPERATION 

7

 

POWERFUL OPERATION 

7

 

TIMER OPERATION (ON/OFF TIMER) 

7

 

CLEANING 

8

 

WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

9

 

WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

10

 

INSTALLATION PLACE AND ELECTRICAL WORK 

10

 

SPECIFICATIONS 

10

JG79Y576H01_01En.indd   1

2018/08/23   17:02:37

Содержание TRANE NTYWST30A112A Series

Страница 1: ...IONES Para los clientes Para utilizar esta unidad de forma correcta y segura lea previamente estas instrucciones de funcionamiento NOTICE D UTILISATION A l attention des clients Pour avoir la certitude d utiliser cet appareil correctement et en toute sécurité veuillez lire cette notice d instructions avant de mettre le clima tiseur sous tension Español English Français JG79Y576H01_01En indd 1 2018...

Страница 2: ...nters the refrigerant circuit Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or in jury The use of any refrigerant other than that specified for the system will cause mechanical failure system malfunction or unit breakdown In the worst case this could lead to a serious impediment to securing product safety This appliance is not intended fo...

Страница 3: ... in contact with your eyes wash them thoroughly with clean water and immediately seek medical attention Ensure that the area is well ventilated when the unit is oper ated together with a combustion appliance Inadequate ventilation may cause oxygen starvation Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes Afte...

Страница 4: ...l button Page 6 VANE control button Page 6 Install the remote control ler holder in a place where the signal can be received by the indoor unit Only use the remote controller provided with the unit Do not use other remote controllers If two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controller Outdoor ...

Страница 5: ...e power outlet and or turn the breaker on Installing the remote controller batteries PREPARATION BEFORE OPERATION Press CLOCK gently using a thin instrument Setting current time Changing temperature units ºF ºC Unit is preset with ºF 1 Press RESET while the temperature but tons are pressed Press RESET gently using a thin instrument To change temperature unit from C to F press RESET R E S E T C L O...

Страница 6: ...rom set temperature The room temperature is approach ing the set temperature About 2 to 4 F 1 to 2 C from set tem perature Lighted Not lighted Emergency operation When the remote controller cannot be used Emergency operation can be activated by pressing the emergency operation switch E O SW on the indoor unit Each time the E O SW is pressed the operation changes in the following order 1 Press to s...

Страница 7: ...ges airflow direction in the following order Vertical airflow direction AUTO The vane is set to the most efficient airflow direction horizontal position Manual For efficient air conditioning select upper position for COOL DRY During COOL DRY when the vane is set to position 4 or 5 the vane automati cally moves to position 1 after 0 5 to 1 hour to prevent any condensation from dripping Swing The vane ...

Страница 8: ...timer The unit will turn ON at the set time OFF timer The unit will turn OFF at the set time or blinks Make sure that the current time is set correctly Page 4 2 Press Increase and Decrease to set the time of timer Each press increases or decreases the set time by 10 minutes Press or again to cancel timer Note ON and OFF timers can be set together mark indicates the order of timer operations If pow...

Страница 9: ...aner or rinse with water After washing with water dry it well in shade What is Catechin air filter Catechin is a bioflavonoid that is found in green tea that has both antivi ral and antioxidant qualities In addition to these benefits Catechin also offers excellent deodorizing characteristics Catechin air filter uses this compound to not only improve air quality but also prevent the spread of bacteria ...

Страница 10: ... water to condense Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 4 Is the polarity of the batteries correct Page 4 Are any buttons on the remote controller of other electric appliances being pressed Does not cool The room cannot be cooled sufficiently Is the temperatu...

Страница 11: ...r Portable phone 10 ft 3 m or more 3 ft 1m or more The installation location of the outdoor unit should be at least 10ft 3 m away from the antennas for TV sets radios etc In areas where the reception is weak provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception 1 Set to the highest temperature...

Страница 12: ... cambiar de sitio desmontar alterar ni reparar la unidad Si no se maneja correctamente el acondicionador de aire puede causar fuego descarga eléctrica lesiones escape de agua etc Consulte con su distribuidor Si el cable de alimentación está dañado deberá ser susti tuido por el fabricante o su agente de mantenimiento para evitar cualquier riesgo Al instalar reubicar o reparar la unidad asegúrese de...

Страница 13: ...do de la pila entra en contacto con los ojos lávelos a fondo con agua limpia y acuda a un médico de inmediato Asegúrese de que la zona está bien ventilada cuando la unidad esté en funcionamiento junto con un aparato de combustión Una ventilación inadecuada puede originar falta de oxígeno Coloque el disyuntor en OFF si oye truenos y hay posibilidad de que caigan rayos La unidad puede resultar dañad...

Страница 14: ...ón RESET Página 4 Tapa Deslícela hacia abajo para abrir Use únicamente el controlador remoto suministrado con la unidad No use otro controlador remoto Si dos o más unidades interiores están instaladas cerca unas de otras puede que la unidad que no se pretendía activar responda al controlador remoto Unidad exterior NOMBRE DE LAS PARTES Unidad interior Controlador remoto La apariencia de las unidade...

Страница 15: ...n de las pilas del controlador remoto PREPARACIÓN ANTES DE LA PUESTA EN MARCHA Pulse CLOCK temporizador suavemente utili zando un objeto en punta Ajuste de la hora actual Cambio de unidades de temperatura ºF ºC La unidad esta configurada por defecto con ºF 1 Pulse RESET reini ciar con los botones de temperatura pulsados Pulse RESET reiniciar suavemente utilizando un objeto en punta Para cambiar la ...

Страница 16: ...onamiento cambia en el orden siguiente 1 Pulse para que se ponga en funcionamiento 2 Pulse para seleccionar el modo de funciona miento El modo cambia con cada pulsación de la manera siguiente 3 Pulse o para ajustar la temperatura Cada pulsación eleva o disminuye la temperatura en 1 F 1 C Pulse para apagarlo Cuando vuelva a encenderlo se activará la misma configuración se leccionada si pulsa Funció...

Страница 17: ...uiente AUTO Baja Media Alta Dirección vertical del aire AUTO El deflector se ajusta en la dirección con mayor rendimiento de la dirección del aire posición horizontal Manual Para un mejor rendimiento del acondicionador de aire seleccione la posi ción superior para REFRIGERACIÓN DESHUMIDIFICACIÓN Durante los modos de REFRIGERACIÓN DESHUMIDIFICACIÓN cuando el deflector está en la posición 4 o 5 éste ...

Страница 18: ...TO auto mático La temperatura no puede configurarse mientras está funcionando en POWERFUL potente Vuelva a pulsar para cancelar el modo POWER FUL potente El funcionamiento en POWERFUL potente también se cancela au tomáticamente en 15 minutos o bien cuando se pulsan los botones OFF ON apagado encendido FAN ventilador o ECONO COOL desconexión automática FUNCIONAMIENTO POWERFUL POTENTE FUNCIONAMIENTO...

Страница 19: ...filtro y su carcasa en agua emplada antes de enjuagarlos Puede utilizar detergentes suaves diluidos si no puede eliminar la suciedad Después de limpiarlo con agua déjelo secar completamente a la sombra Instale todas las pestañas del filtro de aire Cada año Cambie el filtro de aire por uno nuevo para un mejor rendimiento Número de las piezas MAC 1415FT E Filtro de aire filtro de aire de taninos Límpiel...

Страница 20: ...as conexiones de los tubos hace que se condense el agua Controlador remoto La pantalla del controlador remoto no aparece o se oscurece La unidad interior no responde a la señal del controlador remoto Están agotadas las pilas Página 4 Es correcta la polaridad de las pilas Página 4 Se ha pulsado algún botón del controla dor remoto de otros aparatos eléctricos Síntoma Explicación y puntos de comproba...

Страница 21: ...r Mantenga un espacio suficiente para evitar distorsiones en imágenes o sonido 3 pies 1 m o más Radio 4 pulg 100 mm o más Sitio seco y bien ventilado 20 pulg 500 mm o más Televisión Teléfono inalám brico o portátil 10 pies 3 m o más 3 pies 1 m o más La unidad exterior debe instalarse por lo menos a 10 pies 3 m de las antenas para equipos de televisión radio etc En zonas de mala recepción si el func...

Страница 22: ...seur pourrait provo quer un risque d incendie d électrocution de blessure ou de fuite d eau etc Contacter un revendeur Si le cordon d alimentation est endommagé il doit être rem placé par le fabricant ou le service après vente du fabricant pour éviter tout risque potentiel Lors de l installation du déplacement ou de l entretien de l ap pareil veiller à ce qu aucune substance autre que le réfrigéra...

Страница 23: ...damment à l eau claire Si du liquide alcalin entre en contact avec les yeux les rincer abondamment à l eau claire et contacter d urgence un méde cin Si le climatiseur est utilisé conjointement avec un appareil à combustion veiller à ce que la pièce soit parfaitement ventilée Une ventilation insuffisante pourrait provoquer un manque d oxygène dans la pièce Couper le disjoncteur par temps d orage La ...

Страница 24: ...on RESET Page 4 Couvercle Le faire coulisser vers le bas pour l ouvrir Installez le support de la télécommande de façon à ce que l unité interne puisse recevoir les signaux Utilisez uniquement la télécommande fournie avec le climatiseur N en utilisez pas d autres Si plusieurs unités internes sont installées côté à côte il se peut que le signal envoyé à une unité interne par la télécommande soit ex...

Страница 25: ...tion des piles dans la télécommande PREPARATIF D UTILISATION Appuyez doucement sur CLOCK à l aide d un ins trument fin Réglage de l heure Changement des unités de température ºF ºC L unité prédéfinie est ºF 1 Appuyez sur RESET lorsque vous enfon cez les touches de température Appuyez doucement sur RESET à l aide d un instrument fin Pour changer l unité de la température entre degrés Celsius C et degr...

Страница 26: ...ement Chaque nouvelle pression sur cette touche vous permet de passer d un mode à l autre dans l ordre suivant 3 Appuyez sur les touches ou pour régler la tempé rature Chaque nouvelle pression sur ces touches vous per met d augmenter ou de diminuer la température de 1 F 1 C Appuyez sur la touche pour arrêter le fonctionne ment du climatiseur Vous avez la possibilité de recouvrer les mêmes réglages...

Страница 27: ...sur cette touche vous permet de modifier la direction du flux d air dans l ordre suivant AUTO Faible Moy Elevée AUTO 1 2 3 4 5 OSCILLATION Direction du flux d air verticale AUTO L ailette se place de façon à ce que la direction du flux d air soit la plus efficace possible position horizontale Manuel Pour obtenir une climatisation efficace sélectionnez la position vers le haut en mode de REFROIDISSEMEN...

Страница 28: ...ouveau sur les touches ou pour annuler le fonctionnement de la minuterie Remarque Les fonctions de démarrage ON et d arrêt OFF de la minuterie peuvent être réglées conjointement Le symbole indique l ordre d application des modes de fonctionnement de la minuterie En cas de coupure d électricité survenant après le réglage de la minuterie MARCHE ARRET voir Page 5 Fonction de redémarrage automatique M...

Страница 29: ...t pas Faites tremper le filtre et son cadre dans de l eau tiède avant de les nettoyer Il est possible d utiliser des détergents doux dilués lorsqu il est impos sible d ôter la saleté Après lavage laisser bien sécher à l ombre Posez toutes les attaches du filtre à air Tous les ans Pour des performances optimales remplacer le filtre d épuration d air Référence MAC 1415FT E Filtre à air filtre à air caté...

Страница 30: ...ain degré de condensation peut se pro duire Télécommande Aucun affichage sur la té lécommande ou affichage indistinct L unité interne ne répond pas au signal de la télécommande Les piles sont elles déchargées Page 4 La polarité des piles est elle correcte Page 4 Avez vous appuyé sur les touches de télé commandes d autres appareils électriques Symptôme Explication points à vérifier Le climatiseur ne...

Страница 31: ...teur intermittent Maintenez un espace suffisant pour éviter toute distorsion de l image ou du son Radio 4 in 100 mm minimum Endroit sec et bien aéré 20 in 500 mm minimum TV Télé phone sans fil ou téléphone portable 10 ft 3 m minimum 3 ft 1 m minimum L unité externe doit être installée à 10 ft 3 m minimum des antennes de TV radio etc Dans des régions où la réception est faible éloigner davantage l un...

Страница 32: ...complete your product registration please visit us at http www metahvac com Be sure to have the model and serial number for each of your indoor and outdoor units ready before starting the registration process If you need assistance registering your products call or write to us at Mitsubishi Electric Trane HVAC US LLC ATTN Customer Care Center 1340 Satellite Boulevard Suwanee GA 30024 Phone 1 800 4...

Отзывы: