19
SUZ-KA50VA.TH
SUZ-KA60VA.TH
OUTDOOR UNIT
Unit:mm
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
(with service port)
Capillary tube
[
3.6
✕
[
2.4
✕
50
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe
[
12.7 (SUZ-KA50VA.TH)
(with heat insulator)
[
15.88 (SUZ-KA60VA.TH)
Refrigerant pipe
[
6.35
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Muffler
#100
Strainer
#100
Receiver
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
SUZ-KA71VA.TH
OUTDOOR UNIT
Unit:mm
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
(with service port)
Capillary tube
[
3.6
✕
[
2.4
✕
50
Capillary tube
[
1.8
✕
[
0.6
✕
1000
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe
[
15.88
(with heat insulator)
Refrigerant pipe
[
9.52
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Oil separator High-pressure
switch
Strainer
#100
Receiver
Outdoor
heat
exchanger
temperature
thermistor
RT68
Strainer
#100
Strainer
#100
Ambient
temperature
thermistor
RT65
OC322A--1qxp 05.10.19 3:28 PM Page 19