73
2. DRY operation
<How to operate>
1
Press POWER ON / OFF button.
2
Press MODE SELECT button to set operation mode to DRY.
3
Check
lamp is ON and set desired temperature with UP or DOWN but-
ton.
NOTES : 1. When
lamp is ON, press TIMER/TEMP button to change the
display to temperature mode.
2. Unable to set temperature. POWER ON/OFF are operated by micro-
processor control automatically.
3. The flashing lamp shows the room temperature.
TIMER
MITSUBISHI ELECTRIC
12
11
10
9
8
7
6
5
4
3
2
1
29
28
27
26
25
24
23
22
21
20
19
18
TIMER
TEMP
TIMER/TEMP.
UP
DOWN
POWER
COOL
ON/OFF
MODE
SELECT
FAN
SPEED
TIMER
MODE
DRY
HEAT
HIGH
LOW
AUTO
STOP
START
g
TEMP
<DRY operation time chart> In case of the room temperature of 23
:
and above.
Thermostat
Indoor fan
Outdoor fan
compressor
1st ON
8min.
1min
.
4min.
3min.
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
(1) Setting temperature
Follow the right chart with according to the initial room temperature. When
the room temperature is 13
:
or under, dry operation does not work.
(2) ON/OFF control
When the room temperature is 23°C or over:
Compressor operates by temperature control and time control.
1
Set temperature is controlled to fall 2°C above from initial set temperature.
2
When the thermostat is ON, the compressor repeats 8 minutes ON and 3 minutes OFF.
When the thermostat is OFF, the compressor repeats 4 minutes OFF and 1 minute ON.
Indoor fan and outdoor fan operate in the same cycle as the compressor.
When the room temperature is under 23°C.
When the thermostat is ON, the compressor repeats 2 minutes ON and 3 minutes OFF.
When the thermostat is OFF, the compressor repeats 4 minutes OFF and 1 minute ON.
(3) Coil frost prevention
The operation is same as that of coil frost prevention during COOL mode.
However the indoor fan speed becomes the set speed or Low.
OC281-B-3.qxp 04.2.10 2:23 PM Page 73