2-11
Installation
2Unpacking to Installation
rigidity.
shows the maximum reaction force (design values) that may be applied to an installation
stand. Please use these values as reference when designing the installation stand.
Table 2-3 : Magnitude of each reaction force
When installing the robot, secure following space.
・ Connection space for connecting machine cables behind the robot.
・ Maintenance space for replacing the batteries in front of the robot.
・ Maintenance space for removing No.2 arm cover above the robot.
And don't install the robot arm in the position where direct rays or the heat of lighting
hits. The skin temperature of the robot arm may rise, and the error may occur.
When leading machine cables, fix cables in the position near connectors as much as
possible not to apply excessive force or the cable's weight on the connectors.
This robot is hanging installation type. Do not put the robot in an inverted position. It
may cause oil leakage or faults.
Item
Unit
Value
Tilt moment
: M
L
N ・ m
610
Torsional moment
: M
T
N ・ m
807
Horizontal direction translation force
: F
H
N
1,575
Vertical direction translation force : F
V
N
712
CAUTION
CAUTION
Maintenance space
for removing No.2
arm cover.
Maintenance space for
replacing the batteries.
Connection space for
connecting the machine cable.
Fix machine cables.
CAUTION